<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" dtd-version="3.0">
  <front>
    <journal-meta>
<journal-id journal-id-type="publisher">JSSS</journal-id>
<journal-title-group>
<journal-title>Journal of Sensors and Sensor Systems</journal-title>
<abbrev-journal-title abbrev-type="publisher">JSSS</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">J. Sens. Sens. Syst.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2194-878X</issn>
<publisher><publisher-name>Copernicus GmbH</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>

    <article-meta>
      <article-id pub-id-type="doi">10.5194/jsss-4-255-2015</article-id><title-group><article-title>State determination of catalytic converters based on an ultra-wideband
communication system</article-title>
      </title-group><?xmltex \runningtitle{State determination of catalytic converters}?><?xmltex \runningauthor{I.~Motroniuk et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Motroniuk</surname><given-names>I.</given-names></name>
          <email>mrt@uni-bayreuth.de</email>
        <ext-link>https://orcid.org/0000-0003-0190-0978</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Stöber</surname><given-names>R.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Fischerauer</surname><given-names>G.</given-names></name>
          
        </contrib>
        <aff id="aff1"><institution>Bayreuth Engine Research Center (BERC),  Universität Bayreuth, Bayreuth,
Germany</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">I. Motroniuk (mrt@uni-bayreuth.de)</corresp></author-notes><pub-date><day>10</day><month>August</month><year>2015</year></pub-date>
      
      <volume>4</volume>
      <issue>2</issue>
      <fpage>255</fpage><lpage>262</lpage>
      <history>
        <date date-type="received"><day>8</day><month>May</month><year>2015</year></date>
           <date date-type="rev-recd"><day>16</day><month>July</month><year>2015</year></date>
           <date date-type="accepted"><day>20</day><month>July</month><year>2015</year></date>
      </history>
      <permissions>
<license license-type="open-access">
<license-p>This work is licensed under a Creative Commons Attribution 3.0 Unported License. To view a copy of this license, visit <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/3.0/">http://creativecommons.org/licenses/by/3.0/</ext-link></license-p>
</license>
</permissions><self-uri xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015.html">This article is available from https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015.html</self-uri>
<self-uri xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015.pdf">The full text article is available as a PDF file from https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015.pdf</self-uri>


      <abstract>
    <p>A novel microwave-based approach for monitoring the state of aftertreatment
systems such as diesel particulate filters (DPFs), three-way catalytic
converters (TWCs), and selective catalytic reduction (SCR) catalysts is
proposed. The volume inside the metallic housing of the DPF, TWC, or SCR is
considered as a wireless communication channel between two terminals of a
communication system. It is shown that, depending on the transmission
channel characteristics, the properties of the catalyst, such as the
catalyst state, can be inferred. This is done by means of an ultra-wideband
(UWB) measurement and the subsequent evaluation and processing of the
waveform in the time and frequency domains.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

      <?xmltex \hack{\allowdisplaybreaks}?>
<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p>Modern regulations for exhaust gas components like Euro 5 and Euro 6 require
new methods both for the emissions control and for the monitoring and
operation of the emission control systems in the diesel and gasoline
engines.</p>
      <p>During diesel engine operation, soot is captured in the pores of the DPFs (diesel particulate filters) or
the SCR (selective catalytic reduction) catalysts. The ceramic filters must be periodically regenerated to
avoid blocking. Hence,   knowledge about the soot load is useful for the
engine control in a number of ways (Feulner et al., 2013; Rose and Boger,
2009; Ochs et al., 2010; Sappok et al., 2010).</p>
      <p>For gasoline engines, a TWC (three-way catalytic
converter) is used to keep the polluting emissions low. The
TWC stores and releases oxygen depending on the operating conditions. As in
the DPF case, it would be of great advantage from the control engineering
point of view to know the oxygen loading. However, it is the state of the
art that the loading state cannot be measured directly  but is derived
indirectly from the oxygen concentration in the exhaust gas stream before
and after the catalytic converter. The oxygen-measuring elements (so-called
lambda probes) are implemented for the loading state estimation (Twigg,
2007).</p>
      <p>There are a few known approaches for the direct measurement of the desired
internal parameters (Zimmermann, 2007; Reiß et al., 2009). These and
other similar ones also based on physical sensors can deliver only local
information about the catalyst. However, one can learn nothing about the
global state, such as the overall loading degree. Additionally, these
approaches suffer from the complexities involving the mounting of the
sensors in the catalyst and the communication with them.</p>
      <p>Since the catalytic converter is typically located in a metallic housing, it
and its housing together act as a filled cavity resonator. The resonances
are influenced by the changes of material parameters in the catalyst so that
the catalyst state can be determined from the appropriate signal
characteristics of the resonances. The feasibility of this approach is well
documented in the literature (Fischerauer et al., 2008,
2010b; Eichelbaum et al., 2012; Moos et al., 2013). Typically, to observe
the cavity resonances, one or two simple thin probe feeds (short stubs) are
connected to an automatic vector network analyzer (VNA) via coaxial lines.
The changes in the resonant cavity are observed via the scattering matrix
parameters <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> measured by the VNA in the laboratory conditions.</p>
      <p>It has also been shown that the microwave-based direct observation of TWCs
enables superior engine control strategies compared to the indirect
observation by way of lambda probes. This superiority consists, for
instance, in lower emission levels (Schödel et al., 2014a, b).</p>
      <p>The described laboratory equipment cannot be used in the field, i.e., inside
a vehicle or in the manufacturing plant, owing to space and cost reasons.
For the practical application, it should be replaced by smaller and cheaper
solutions.</p>
      <p>For solving this miniaturizing task, we have described a novel approach
towards the monitoring of exhaust gas aftertreatment systems such as DPFs,
SCRs, and TWCs (Motroniuk et al., 2014). It was proposed to consider the
interior of the catalyst metal housing as a wireless communication channel.
The effect of the catalyst state on such communication parameters as the bit
error rate (BER), the packet error rate (PER), the ratio of the energy per
bit to the noise power spectral density <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mtext>b</mml:mtext></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>N</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and the data receive
rate (Rx data rate) was demonstrated by way of an example. The described
approach involves a small-size and cost-effective modular architecture and
has the potential for field application, unlike approaches based on
laboratory equipment  such as automatic vector network analyzers.</p>
      <p>In a recent conference contribution, we proposed a modification of our novel
approach. Instead of measuring certain communication channel parameters
(such as BER, PER, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mtext>b</mml:mtext></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>N</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> levels, and Rx data rate), an ultra-wideband
(UWB) pulse is to be transmitted through the catalyst and the changes
suffered by it on its way through the catalyst are to be evaluated by a
receiving device (Motroniuk et al., 2015). In other words, the propagation
medium characteristics and the catalyst state are to be estimated from the
UWB waveform changes.</p>
      <p>In this contribution, we consider an extension of the UWB approach for the
catalyst state determination. It is based on the subsequent evaluation and
post-processing of the UWB waveforms in the time and frequency domains.</p>
      <p>The rest of the paper is organized as follows. In Sect. 2, a novel wireless
approach is presented, followed by a description of a hardware
implementation and of an experimental verification with DPF in the time and
frequency domains in Sects. 3 and 4, respectively. The conclusions are
presented in Sect. 5.</p>
</sec>
<sec id="Ch1.S2">
  <title>Novel wireless approach</title>
      <p>It is proposed to consider the interior of the catalyst housing as a
communication channel between two terminals of a UWB wireless communication
system. The most important parameters during the data transmission are the
characteristics of the communication channel (in our case the catalyst).
From the wireless channel characteristics, the properties of the catalytic
converter such as the catalyst oxygen concentration or soot loading state
can be determined. The latter assertion about the measurability of the soot
loading state has been demonstrated in Motroniuk et al. (2014) and will be
further corroborated in the remainder of this contribution. The former
assertion about the measurability of the oxygen concentration follows from
the fact that the electrical properties of catalysts depend heavily on their
oxidization state; hence, this state can be inferred from the transmission
or reflection details of electromagnetic microwaves (Fischerauer et al.,
2008; Eichelbaum et al., 2012).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><caption><p>Basic structure of the proposed measurement system.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f01.pdf"/>

      </fig>

      <p>The basic structure of the proposed measurement system is shown in Fig. 1.
The system consists of a conductive (usually metallic) housing of the
catalyst (1) and the catalyst itself (2). Two gas-permeable conductive grids (3, 4)
which limit the resonating cavity are of advantage  but not
absolutely necessary. The grids are effectively short-circuiting the
electric field, thus precisely defining the resonating cavity. Two
thin-probe feeds (short stubs 5, 6) serve to connect the cavity with the
system environment, i.e., with communication end devices (7, 8), by coaxial
cables, which are used for signal transmission and reception. The short
stubs play the same role for the communication system as the antennas in the
common message transmission and the catalyst in its housing plays the same
role as the wireless communication channel for the ordinary message
transmission.</p>
      <p>The signal transmitted through the wireless channel inside the catalyst
suffers from such effects as attenuation, fading, multipath propagation,
scattering, etc. Note, however, that the sender and receiver in a common
wireless transmission link are located in the far field of each other
whereas, in the present context, they are located in the near field. This,
together with the resonance phenomena in the catalyst-filled cavity,
introduces new propagation-path effects compared to wireless transmission
links. The characteristics of the received information transferred from the
transmitter to the receiver depend on the propagation medium. The effect on
the signal is similar to the effect of buildings, trees, autos, rain,
humidity, etc. in common wireless communication links: the channel
characteristics influence the signal received, either in the time or
frequency domain. Here, the closed-space propagation through the soot-loaded
or otherwise chemically altered catalyst medium affects the received signal
waveform.</p>
      <p>In this paper, we specifically focus on a UWB communication system. Rather
than measuring individual channel parameters, such as BER, PER,
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mtext>b</mml:mtext></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>N</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> levels, or the Rx data rate (Motroniuk et al., 2014), or than
measuring the S-parameters of a microwave two-port (Fischerauer et al.,
2008), it is the integral UWB pulse waveform transmitted through the device
under test (catalyst) which is considered. It is postulated that physical
changes of the catalyst material caused by the absorption or desorption of
soot or chemical species are mirrored in the waveform received, or its
spectral representation.</p>
      <p>The goal, of course, is to estimate the internal state of a catalyst by this
approach in a manner substantially simpler than possible with the system
architectures demonstrated so far. This is achieved because the measurement
can be performed by the existing hardware (wireless communication modules)
and software (signal processing techniques for the wireless communication
systems).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><caption><p>Functional diagram of the proposed measurement system.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f02.pdf"/>

      </fig>

      <p>The functional diagram of such a system is shown in Fig. 2. A pulse
generator generates the UWB waveform, which is then transmitted through the
device under test (catalyst) and distorted in this process. On the receiver
side, the UWB pulse waveform is measured to indirectly estimate the catalyst
state.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><caption><p>Exemplary hardware implementation of the proposed measurement
system.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f03.pdf"/>

      </fig>

</sec>
<sec id="Ch1.S3">
  <title>Hardware implementation</title>
      <p>Figure 3 depicts some possible ways to implement the architecture proposed
in actual hardware. The UWB pulse generation and the transmission are
accomplished by a communication module (we have used a Time Domain PulsON
P410 module), and the receiver is implemented by another communication
module (also PulsON P410). After receiving the pulse modulated by the
catalyst properties, it is a matter of experience (calibration, simulation
results, etc.) to infer the catalyst state from the waveform
distortion.</p>
      <p>Devices such as Altera Stratix, Xilinx Virtex, Xilinx Spartan, ZigBee,
WirelessHART, Nanonet, PulsON 410, or any other including (but not limited
to) field-programmable gate-array (FPGA)-based integrated circuits and
devices could be used for building an appropriate communication system for
the intended application purpose. The catalyst state can be estimated by a
post-processing of the received UWB waveform with the numerical computing
environments and programming languages (such as MATLAB and  C).</p>
</sec>
<sec id="Ch1.S4">
  <title>Experimental verification with DPF</title>
<sec id="Ch1.S4.SS1">
  <title>Validation in the time domain</title>
      <p>The validity of the approach was tested with DPFs loaded with different
amounts of soot. The aim of the tests was to compare the effect of the soot
load on the communication channel and, as a result, on the received UWB
waveforms in order to prove the validity of the, as we believe, novel
approach towards the monitoring and estimation of catalyst states.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><caption><p>Soot load of the measured DPFs (Fischerauer et al., 2010a).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">DPF</oasis:entry>  
         <oasis:entry colname="col2">Soot load</oasis:entry>  
         <oasis:entry colname="col3">Soot load per DPF</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">number</oasis:entry>  
         <oasis:entry colname="col2">(g)</oasis:entry>  
         <oasis:entry colname="col3">volume (g L<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">1</oasis:entry>  
         <oasis:entry colname="col2">0</oasis:entry>  
         <oasis:entry colname="col3">0</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">2</oasis:entry>  
         <oasis:entry colname="col2">4.6</oasis:entry>  
         <oasis:entry colname="col3">2.0</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">3</oasis:entry>  
         <oasis:entry colname="col2">13.6</oasis:entry>  
         <oasis:entry colname="col3">5.8</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p>One of the DPFs was clean (not used, with 0 g of soot), another one was
loaded with 4.6 g of soot, and the third one was loaded with 13.6 g of soot.
The filters used and their soot loading are listed in Table 1. For details of
the catalyst geometry, the reader is referred to Fischerauer et al. (2010a).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><caption><p>UWB waveforms for three DPFs loaded with different amounts of
soot.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f04.pdf"/>

        </fig>

      <p>The UWB pulse waveforms recorded during the communication between two
commercial PulsON P410 modules via the interior of the DPF-loaded metal
housing look substantially different for the various DPFs (Fig. 4). In
particular, multiple-transit signals inside the catalyst housing (occurring
after 18 ns in Fig. 4) are   more attenuated  the higher the soot load is.
This is explained by the fact that the conducting soot introduces losses
into the system. Thus, a wave packet is attenuated each time it traverses
the soot-loaded DPF, and this attenuates multiple-transit signals more than
the single-transit (direct input-to-output) signal. In Fig. 4 the vertical
scale represents A–D (analog-to-digital) counts proportional to volts as
output by the analog-to-digital converter (ADC) in the UWB chip.</p>
      <p>The envelopes <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>e</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of the time-domain responses shown in Fig. 4 have been
computed as the magnitude of the analytic signal constructed from the
original time response <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> by adding to it its Hilbert transform (Marko,
1982):

                <disp-formula id="Ch1.E1" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi>e</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mo>|</mml:mo><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mi>j</mml:mi><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo mathvariant="normal" stretchy="false">^</mml:mo></mml:mover><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>|</mml:mo><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mtext>with</mml:mtext><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo mathvariant="normal" stretchy="false">^</mml:mo></mml:mover><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mfrac><mml:mn mathvariant="normal">1</mml:mn><mml:mi mathvariant="italic">π</mml:mi></mml:mfrac><mml:munderover><mml:mo movablelimits="false">∫</mml:mo><mml:mrow><mml:mo>-</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow><mml:mi mathvariant="normal">∞</mml:mi></mml:munderover><mml:mfrac><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:mi>t</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="italic">τ</mml:mi></mml:mrow></mml:mfrac><mml:mtext>d</mml:mtext><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>Of course, all signals are discrete in time so that Eq. (1) had to be evaluated
in the form
<?xmltex \hack{\addtocounter{equation}{-1}}?>

                <disp-formula id="Ch1.E2" specific-use="align" content-type="subnumberedsingle"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E2.1"><mml:mtd/><mml:mtd><mml:mrow><mml:mi>e</mml:mi><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mo>|</mml:mo><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mi>j</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo mathvariant="normal" stretchy="false">^</mml:mo></mml:mover><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>|</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:mtext>with</mml:mtext><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mover accent="true"><mml:mi>u</mml:mi><mml:mo stretchy="false" mathvariant="normal">^</mml:mo></mml:mover><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:mfrac><mml:mn mathvariant="normal">1</mml:mn><mml:mi mathvariant="italic">π</mml:mi></mml:mfrac><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mtable class="array" columnalign="center"><mml:mtr><mml:mtd><mml:mrow><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>min⁡</mml:mo></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mrow><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>≠</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:mtd></mml:mtr></mml:mtable><mml:mrow><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:munderover><mml:mfrac><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:mi>k</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi></mml:mrow></mml:mfrac><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula></p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><caption><p>Envelopes of the time-domain responses from Fig. 4.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f05.pdf"/>

        </fig>

      <p>The result is shown in Fig. 5. One clearly observes a substantial difference
in the signal envelopes depending on the soot content in the DPF. In
particular, this can be seen starting from the second peek at around 16 ns.
The soot loading state is not observable via the first peak because of the
technical characteristics of the equipment (at the beginning of the received
UWB pulse, the Tx pulse coupling through the Tx switch is showing through).</p>
      <p>To quantify the differences, we calculated the convolution of the envelope
functions for different DPF states, as always defined by

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E3"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:munderover><mml:mo movablelimits="false">∫</mml:mo><mml:mrow><mml:mo>-</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow><mml:mrow><mml:mo>+</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow></mml:munderover><mml:msub><mml:mi>e</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>)</mml:mo><mml:mrow class="chem"><mml:mspace width="0.125em" linebreak="nobreak"/></mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>)</mml:mo><mml:mrow class="chem"><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">d</mml:mi></mml:mrow><mml:mi mathvariant="italic">τ</mml:mi><mml:mspace width="1em" linebreak="nobreak"/><mml:mtext>or</mml:mtext></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>min⁡</mml:mo></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:munderover><mml:msub><mml:mi>e</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>

            (Fig. 6; when comparing the <inline-formula><mml:math display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axis scaling of this and other figures to the
scalings in Motroniuk et al. (2015), note that discrete convolution,
correlation, and Fourier-transform formulas were used in the reference,
whereas we have used the continuous-signal formulas in the current
contribution. For example, the continuous-signal convolution approximately
computed by Eq. (2) and the discrete convolution differ by a factor of
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> – the sampling interval – and this results in different <inline-formula><mml:math display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axis
scalings.) The effect of the soot load on the curves is clearly seen.
Multiple-transit signals are more attenuated with increasing soot load. The
amplitude of the convolved signals at 50 ns is around 13 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">9</mml:mn></mml:msup></mml:math></inline-formula> (A–D
counts) <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 61 ps (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:mn>0.79</mml:mn></mml:mrow></mml:math></inline-formula> s for the empty/4.6 g case  but
only 8.9 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">9</mml:mn></mml:msup></mml:math></inline-formula> (A–D counts) <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 61 ps <inline-formula><mml:math display="inline"><mml:mo>≈</mml:mo></mml:math></inline-formula> 0.54 s for the
empty/13.6 g case.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><caption><p>Convolution of the envelopes of the time-domain responses (Fig. 5).</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f06.pdf"/>

        </fig>

      <p>The difference is observable by the width of the convolution curves as well.
Measured at an amplitude of 3.28 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">9</mml:mn></mml:msup></mml:math></inline-formula> (A–D counts) <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 61 ps (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, this width amounts to 52, 42, and 27 ns, respectively, for the
three cases.</p>
      <p>We also calculated the cross-correlation of the envelope functions, given by

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E4"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi mathvariant="normal">Φ</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:munderover><mml:mo movablelimits="false">∫</mml:mo><mml:mrow><mml:mo>-</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow><mml:mrow><mml:mo>+</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow></mml:munderover><mml:msub><mml:mi>e</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>)</mml:mo><mml:mtext>d</mml:mtext><mml:mi mathvariant="italic">τ</mml:mi><mml:mspace width="1em" linebreak="nobreak"/><mml:mtext>or</mml:mtext></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi mathvariant="normal">Φ</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>min⁡</mml:mo></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:munderover><mml:msub><mml:mi>e</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula></p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><caption><p>Auto-correlation functions of the envelopes shown in Fig. 5.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f07.pdf"/>

        </fig>

      <p>For <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mi>j</mml:mi></mml:mrow></mml:math></inline-formula>, this turns into the auto-correlation <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">Φ</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of the
envelope function (Fig. 7). In particular, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">Φ</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>(0) is
proportional  to the signal power. Figure 7 clearly reveals that the signal
power and the other values of the auto-correlation function decrease with
the soot load. This is to be expected as more soot means higher signal
attenuation, which in turn means smaller signal amplitudes at the receiver.
In numbers, the maximum of the auto-correlation function is
3.2 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn>10</mml:mn></mml:msup><mml:mo>×</mml:mo><mml:mn>61</mml:mn></mml:mrow></mml:math></inline-formula> ps (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo></mml:mrow></mml:math></inline-formula> 1.96 s,
<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.8</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mn>10</mml:mn></mml:msup><mml:mo>×</mml:mo><mml:mn>61</mml:mn></mml:mrow></mml:math></inline-formula> ps <inline-formula><mml:math display="inline"><mml:mo>≈</mml:mo></mml:math></inline-formula> 1.11 s, and 1 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn>10</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps <inline-formula><mml:math display="inline"><mml:mo>≈</mml:mo></mml:math></inline-formula> 0.64 s for the empty DPF, the DPF
loaded with 4.6 g soot, and the DPF loaded with 13.6 g, respectively. Again,
the differences are also observable via the signal width.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8"><caption><p>Cross-correlation functions of the envelopes shown in Fig. 5.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f08.pdf"/>

        </fig>

      <p>Finally, Fig. 8 shows the cross-correlation functions. The amplitudes and
mean values of the peaks are among the parameters suitable for a DPF state
estimation algorithm. The maximum amplitude was 2.2 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn>10</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps
(<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo></mml:mrow></mml:math></inline-formula> 1.35 s, 1.5 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn>10</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps <inline-formula><mml:math display="inline"><mml:mo>≈</mml:mo></mml:math></inline-formula> 0.92 s, and
1.3 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn>10</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps <inline-formula><mml:math display="inline"><mml:mo>≈</mml:mo></mml:math></inline-formula> 0.8 s for the cross-correlations of the
three envelope signals from Fig. 5. The mean values were
2.8 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">9</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo></mml:mrow></mml:math></inline-formula> 0.17 s, 1.8 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">9</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps <inline-formula><mml:math display="inline"><mml:mo>≈</mml:mo></mml:math></inline-formula> 0.11 s,
and 1.1 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">9</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps <inline-formula><mml:math display="inline"><mml:mo>≈</mml:mo></mml:math></inline-formula> 0.07 s for the three cases,
respectively.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9"><caption><p>Smoothed envelopes of the time-domain responses from Fig. 4.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f09.pdf"/>

        </fig>

      <p>Owing to the rapid amplitude variation of the envelope curves in Fig. 5, it
makes sense to first smooth them before further processing (Fig. 9). The
amplitude of the smoothed envelopes depends on the soot load – with
increasing soot load, the amplitude measured at the receiver becomes lower.</p>
      <p>One possible way of processing is to correlate certain features of these
smoothed curves with the DPF soot load. This is demonstrated in Fig. 10 for
the center of gravity of the areas bounded by the curves in Fig. 9 and the
time axis. It is obvious that this characteristic curve may be used to
estimate the soot load from the measured time-domain response of the UWB
system. It is also obvious that the sensitivity of this measurement system
decreases with increasing soot load.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10"><caption><p>Time coordinate of the center of gravity of the area bounded by
the smoothed envelopes and the time axis in Fig. 9.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f10.pdf"/>

        </fig>

      <p>Along the same line of reasoning, we have computed the characteristic curves
linking the maximum and the average values of the smoothed envelopes with
the DPF soot load (Fig. 11).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11"><caption><p>Maximum and average values of the smoothed envelopes (Fig. 9).</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f11.pdf"/>

        </fig>

      <p>While the overall behavior of the characteristic curves in Figs. 10 and 11
is quite similar, there are differences in the details. It appears as if small
soot loads can be better resolved (measured with a higher sensitivity) by
way of the center-of-gravity feature (Fig. 10) than by the other features.
This would be quite interesting, but, in our opinion, it is too early to
draw such conclusions as the number of measurements we have performed so far
is much too small to allow for any substantial insight into the statistics of
the measurement approach.</p>
      <p>Besides, it is also important to note that the curves will look different
with different transmitting power because of receiver sensitivity. This,
too, will have to be investigated in more detail.</p>
</sec>
<sec id="Ch1.S4.SS2">
  <title>Validation in the frequency domain</title>
      <p>According to the results presented in Sect. 4.1, the state of automotive
aftertreatment systems can possibly be inferred from the time-domain
characteristics of UWB signals. However, in some cases, it may be easier to
characterize and evaluate signals in the frequency domain. This will be
considered in the present section.</p>
      <p>UWB spectra for the three waveforms from Fig. 4 are shown in Fig. 12 (the
spectral range from 3.1 to 5.3 GHz corresponds to the product specifications
of the communication units used). One clearly observes substantial
differences in the spectral amplitudes between the soot loading degrees,
especially at the resonance peaks of 3.18, 3.4, 3.57, 4.0, 4.16, 4.4 GHz,
etc. For example, the magnitude of the UWB spectrum at 3.4 GHz amounts to
7.6 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">5</mml:mn></mml:msup></mml:math></inline-formula> (A–D counts) <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 61 ps (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:mn>4.6</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> s for
the empty DPF, to 5.9 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">5</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn>3.6</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> s for the
4.6 g load, and to 4.3 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">5</mml:mn></mml:msup><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> 61 ps <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn>2.6</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> s for the
13.6 g load. Obviously, the signals are   more attenuated  the higher the
soot load is.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F12"><caption><p>UWB magnitude spectrum for three different DPF loading states
corresponding to the time-domain signals in Fig. 4.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f12.pdf"/>

        </fig>

      <p>The convolution of the UWB magnitude spectra from Fig. 12 with each other is
calculated with

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E5"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:munderover><mml:mo movablelimits="false">∫</mml:mo><mml:mrow><mml:mo>-</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow><mml:mrow><mml:mo>+</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow></mml:munderover><mml:msub><mml:mi>U</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi>U</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>f</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>)</mml:mo><mml:mtext>d</mml:mtext><mml:mi mathvariant="italic">φ</mml:mi><mml:mspace linebreak="nobreak" width="1em"/><mml:mtext>or</mml:mtext></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>min⁡</mml:mo></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:munderover><mml:msub><mml:mi>U</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi>U</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>

            and plotted in Fig. 13. The maximum magnitude of the convolved signals in
the frequency domain is around 0.29 s for the empty/4.6 g case, 0.21 s for
the empty/13.6 g case, and only 0.17 s for the 4.6 g/13.6 g case.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F13"><caption><p>Convolution of the UWB magnitude spectra from Fig. 12.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f13.pdf"/>

        </fig>

      <p>Figure 14 shows the auto-correlation functions of the UWB magnitude spectra
from Fig. 12, calculated with

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E6"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi mathvariant="normal">Φ</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:munderover><mml:mo movablelimits="false">∫</mml:mo><mml:mrow><mml:mo>-</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow><mml:mrow><mml:mo>+</mml:mo><mml:mi mathvariant="normal">∞</mml:mi></mml:mrow></mml:munderover><mml:msub><mml:mi>U</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi>U</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>f</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>)</mml:mo><mml:mtext>d</mml:mtext><mml:mi mathvariant="italic">φ</mml:mi><mml:mspace linebreak="nobreak" width="1em"/><mml:mtext>or</mml:mtext></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi mathvariant="normal">Φ</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>min⁡</mml:mo></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:munderover><mml:msub><mml:mi>U</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi>U</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="normal">ℓ</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>

            and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mi>j</mml:mi></mml:mrow></mml:math></inline-formula>. With increasing soot load, the magnitude of these
auto-correlation functions decreases. The maximum magnitude observed was 0.49, 0.28,
and 0.16 s for the empty DPF, the DPF loaded with 4.6 g soot, and
the DPF loaded with 13.6 g, respectively. As in the time-domain case, the
difference is also observable via the signal width.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F14"><caption><p>Auto-correlation functions of the UWB magnitude spectra in Fig. 12.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f14.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F15"><caption><p>Cross-correlation functions of the UWB magnitude spectra in Fig. 12.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f15.pdf"/>

        </fig>

      <p>Figure 15 presents the cross-correlation functions of the UWB magnitude
spectra, Eq. (5) with <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>≠</mml:mo><mml:mi>j</mml:mi></mml:mrow></mml:math></inline-formula>. The maximum magnitudes were 0.35, 0.24,
and 0.19 s for the cross-correlations of the three signals obtained with
different soot loads.</p>
      <p>Furthermore, we have prepared histograms of the spectral magnitudes,
measured in A–D counts, for three different DPF loading states. The results
are presented in Fig. 16. The frequency range evaluated was 3.1–5.3 GHz,
consistent with the product specifications of the communication units used.
The area of every rectangle in the histogram represents the relative
frequency of the spectral magnitudes falling into the interval marked by the
rectangle basis. The height of the rectangle is the relative frequency
density (the relative frequency of the spectral magnitudes associated with
the rectangle interval, divided by the width of the rectangle).</p>
      <p>An appropriate empirical probability density function (pdf) used to fit the
actually observed histogram must be one-sided and supported on the interval
[0, <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula>] because the spectral magnitudes are non-negative numbers.
Possible candidates, among others, are the Pareto distribution and the
exponential distribution, both of which are often used in connection with
system failure models. Here, we used the exponential distribution
            <disp-formula id="Ch1.E7" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi>f</mml:mi><mml:mo>(</mml:mo><mml:mi>x</mml:mi><mml:mo>;</mml:mo><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mi mathvariant="italic">β</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mfenced close="" open="{"><mml:mtable class="array" columnalign="center center"><mml:mtr><mml:mtd><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mi mathvariant="italic">β</mml:mi></mml:mfrac></mml:mstyle><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mi>x</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="italic">β</mml:mi></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="1em"/></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mrow class="chem"><mml:mi mathvariant="normal">for</mml:mi></mml:mrow><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mi>x</mml:mi><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mrow><mml:mn mathvariant="normal">0</mml:mn><mml:mspace linebreak="nobreak" width="1em"/></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mrow class="chem"><mml:mi mathvariant="normal">for</mml:mi></mml:mrow><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mi>x</mml:mi><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F16"><caption><p>Histogram of the UWB magnitude spectrum for different loading
states (bars) and best fits by exponential distributions <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>p</mml:mi><mml:mo>(</mml:mo><mml:mi>x</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mi mathvariant="italic">β</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mi>x</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="italic">β</mml:mi></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (lines).</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f16.pdf"/>

        </fig>

      <p>The exponential distributions with best-fitting parameters <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> are also
shown in Fig. 16. The widths of the histograms decrease with the soot
content or, in other words, the standard deviation of the pdf decreases with
the soot content. As before, this is to be expected: more soot means higher
attenuation, which in turn results in smaller signal amplitudes at the
receiver.</p>
      <p>One would expect that more soot load (i.e., higher attenuation) would
smooth the spectrum in the sense that the magnitude variations become
smaller; this would correspond to a pdf graph with steeper skirts and
smaller width. In numbers, this would mean that the pdf parameter <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>
increases with the soot load. The graphs in Fig. 16 support this assumption
in principle (compare the 0 and  13.6 g soot cases), but one
cannot infer a clear quantitative trend (compare the 4.6  and 13.6 g soot cases). On the other hand, given the small number of cases
studied so far (only three different soot load values), there is not enough
evidence to rule out the existence of a useful relationship between the soot
load and the properties of the pdf describing the signal spectrum picked up
by the receiver.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F17"><caption><p>Maximum and average magnitudes of the signal spectrum at the
receiver as functions of the soot load (from Fig. 12).</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/4/255/2015/jsss-4-255-2015-f17.pdf"/>

        </fig>

      <p>Finally, in analogy with the approach visualized for the time domain in
Fig. 11, Fig. 17 depicts the maximum and average values for the magnitude
spectrum in the range between 3.1 and 5.1 GHz. As before, the curves look
promising in that they are monotonic and would allow for a unique inversion of
the form “signal feature <inline-formula><mml:math display="inline"><mml:mo>→</mml:mo></mml:math></inline-formula> soot load”.</p>
</sec>
</sec>
<sec id="Ch1.S5" sec-type="conclusions">
  <title>Conclusions</title>
      <p>We have reported on a novel approach for the monitoring of exhaust gas
aftertreatment systems, such as DPFs, SCRs, and TWCs, the most attractive
feature of which is that it is based on a cost-effective modular
architecture. Hence, it can be implemented in situ, e.g., in a car.</p>
      <p>In the approach proposed, the interior of the catalyst metal housing serves
as a communication channel between two wireless communication nodes. To be
more specific, we investigated a UWB-based architecture. It was demonstrated
experimentally by way of various soot-loaded DPFs  that the catalyst
chemistry (i. e., the soot load of the DPF) affects the channel
characteristics strongly enough to allow for the identification of the DPF state
from the UWB signal details in the time as well as the frequency domains.</p>
      <p>In particular, we were able to show that, in principle, certain features of
the received time- and frequency-domain signals depend in a manner on the
soot load which allows for the inversion of the feature vs. soot load
characteristics. Among these features were the position of the center of
gravity of the area bounded by the signal envelope and the time axis, the
maximal value,   the average value of the envelopes in the time domain and
the maximum and average values in the spectra.</p>
</sec>

      
      </body>
    <back><ack><title>Acknowledgements</title><p>The authors thankfully acknowledge financial support by the German Research
Foundation (DFG) under grants Fi 956/3-2 and Fi 956/5-1.<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?>
Edited by: F. L. Dickert<?xmltex \hack{\newline}?>
Reviewed by: two anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>Eichelbaum, M., Stößer, R., Karpov, A., Dobner, C.-K., Rosowski, F.,
Trunschke, A., and Schlögl, R.: The microwave cavity perturbation
technique for contact-free and in situ electrical conductivity measurements
in catalysis and materials science, Phys. Chem. Chem. Phys., 14, 1302–1312,
<ext-link xlink:href="http://dx.doi.org/10.1039/c1cp23462e" ext-link-type="DOI">10.1039/c1cp23462e</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>Feulner, M., Hagen, G., Piontkowski, A., Müller, A., Fischerauer, G.,
Brüggemann, D., and Moos R.: In-Operation Monitoring of the Soot Load of
Diesel Particulate Filters: Initial Tests,
Topics in Catalysis, 56, 483–488, <ext-link xlink:href="http://dx.doi.org/10.1007/s11244-013-0002-9" ext-link-type="DOI">10.1007/s11244-013-0002-9</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>Fischerauer, G., Spörl, M., Gollwitzer, A., Wedemann, M., and Moos, R.:
Catalyst state observation via the perturbation of a microwave cavity
resonator, Frequenz, 62, 180–184, <ext-link xlink:href="http://dx.doi.org/10.1515/freq.2008.62.7-8.180" ext-link-type="DOI">10.1515/freq.2008.62.7-8.180</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Fischerauer, G., Förster, M., and Moos, R.: Sensing the soot load in
automotive diesel particulate filters by microwave methods, Meas. Sci. Technol.,
21, 035108, <ext-link xlink:href="http://dx.doi.org/10.1088/0957-0233/21/3/035108" ext-link-type="DOI">10.1088/0957-0233/21/3/035108</ext-link>, 2010a.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>Fischerauer, G., Spörl, M., Reiß, S., and Moos, R.: Microwave-Based
Investigation of Electrochemical Processes in Catalysts and Related Systems,
Technisches Messen, 77, 419–427, <ext-link xlink:href="http://dx.doi.org/10.1524/teme.2010.0066" ext-link-type="DOI">10.1524/teme.2010.0066</ext-link>, 2010b (in German).</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
Marko, H.: Methoden der Systemtheorie, 2nd Edn., Springer, Berlin, Germany,
1982 (in German).</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>Moos, R., Beulertz, G., Reiß, S., Hagen, G., Fischerauer, G., Votsmeier,
M., and Gieshoff, J.: Overview: Status of the Microwave-Based Automotive Catalyst
State Diagnosis, Top. Catal., 56, 358–364, <ext-link xlink:href="http://dx.doi.org/10.1007/s11244-013-9980-x" ext-link-type="DOI">10.1007/s11244-013-9980-x</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>
Motroniuk, I., Królak, R., Stöber, R., and Fischerauer, G.: State
Observation in Automotive Aftertreatment Systems Based on Wireless
Communication Links, in: Proc. 5th IMEKO TC19 Symp. on Environmental Instrumentation and Measurements,
Chemnitz, Germany, 23–24 September 2014, 122–126, 2014.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
Motroniuk, I., Stöber, R., and Fischerauer, G.: Waveform-Based State
Determination for Catalytic Converters, in: Proc. 17th Int'l Conf. on Sensors
and Measurement Technology (Sensor 2015), Nuremberg, Germany, 19–21 May 2015, 472–477, 2015.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>Ochs, T., Schittenhelm, H., Genssle, A., and Kamp, B.: Particulate Matter Sensor
for On Board Diagnostics (OBD) of Diesel Particulate Filters (DPF), SAE Int. J. Fuels Lubr., 3,
61–69, <ext-link xlink:href="http://dx.doi.org/10.4271/2010-01-0307" ext-link-type="DOI">10.4271/2010-01-0307</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Reiß, S., Wedemann, M., Moos, R., and Rösch, M.: Electrical In Situ
Characterization of Three-Way Catalyst Coatings, in: Proc. 8th Int'l Congress on
Catalysis and Automotive Pollution Control (CAPOC 8), Brussels, Belgium, 15–17 April 2009, 3,
67–74, 2009.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>Rose, D. and Boger, T.: Different Approaches to Soot Estimation as Key
Requirement for DPF Applications, SAE Technical Paper, 2009-01-1262, 11 pp.,
<ext-link xlink:href="http://dx.doi.org/10.4271/2009-01-1262" ext-link-type="DOI">10.4271/2009-01-1262</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>Sappok, A., Bromberg, L., Parks, J., and Prikhodko, V.: Loading and Regeneration
Analysis of a Diesel Particulate Filter with a Radio Frequency-Based Sensor,
SAE Technical Paper, 2010-01-2126, 14 pp., <ext-link xlink:href="http://dx.doi.org/10.4271/2010-01-2126" ext-link-type="DOI">10.4271/2010-01-2126</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>
Schödel, S., Moos, R., Votsmeier, M., and Fischerauer, G.: SI-Engine Control
With Microwave-Assisted Direct Observation of Oxygen Storage Level in
Three-Way Catalysts, IEEE Trans. CST, 22, 2346–2353, 2014a.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Schödel, S., Votsmeier, M., and Fischerauer, G.: Microwave-assisted oxygen
storage level estimation for three-way catalyst control: Model-based
development and benchmarking of selected control strategies, Can. J. Chem. Eng., 92,
1597–1606, 2014b.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>Twigg, M. V.: Progress and future challenges in controlling automotive
exhaust gas emissions, Appl. Catal. B: Environmental, 70, 2–15, <ext-link xlink:href="http://dx.doi.org/10.1016/j.apcatb.2006.02.029" ext-link-type="DOI">10.1016/j.apcatb.2006.02.029</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
Zimmermann, C.: Neuartiger Sensor zur Bestimmung des Zustandes eines
NOx-Speicherkatalysators, PhD Thesis, Univ. Bayreuth, Shaker, Aachen, Germany, 2007 (in
German).</mixed-citation></ref>