<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" dtd-version="3.0">
  <front>
    <journal-meta>
<journal-id journal-id-type="publisher">JSSS</journal-id>
<journal-title-group>
<journal-title>Journal of Sensors and Sensor Systems</journal-title>
<abbrev-journal-title abbrev-type="publisher">JSSS</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">J. Sens. Sens. Syst.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2194-878X</issn>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>

    <article-meta>
      <article-id pub-id-type="doi">10.5194/jsss-6-351-2017</article-id><title-group><article-title>Transmitted light pH optode for small sample volumes</article-title>
      </title-group><?xmltex \runningtitle{Transmitted light pH optode for small sample volumes}?><?xmltex \runningauthor{C. Rogge et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Rogge</surname><given-names>Christian</given-names></name>
          <email>rogge@th-wildau.de</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Zinn</surname><given-names>Steffen</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Prosposito</surname><given-names>Paolo</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Francini</surname><given-names>Roberto</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Foitzik</surname><given-names>Andreas H.</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>University of Applied Science Wildau, Department of Engineering and Natural Sciences, <?xmltex \hack{\break}?>15745 Wildau, Germany</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>University of Rome Tor Vergata, Department of Industrial Engineering and INSTM, <?xmltex \hack{\break}?>Via del Politecnico 1, 00133 Rome, Italy</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Christian Rogge (rogge@th-wildau.de)</corresp></author-notes><pub-date><day>16</day><month>October</month><year>2017</year></pub-date>
      
      <volume>6</volume>
      <issue>2</issue>
      <fpage>351</fpage><lpage>359</lpage>
      <history>
        <date date-type="received"><day>30</day><month>September</month><year>2016</year></date>
           <date date-type="rev-recd"><day>7</day><month>July</month><year>2017</year></date>
           <date date-type="accepted"><day>2</day><month>August</month><year>2017</year></date>
      </history>
      <permissions>
<license license-type="open-access">
<license-p>This work is licensed under the Creative Commons Attribution 3.0 Unported License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/3.0/">https://creativecommons.org/licenses/by/3.0/</ext-link></license-p>
</license>
</permissions><self-uri xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017.html">This article is available from https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017.html</self-uri>
<self-uri xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017.pdf">The full text article is available as a PDF file from https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017.pdf</self-uri>


      <abstract>
    <p>An innovative concept of a low-cost pH optode with working volumes of less
than 150 <inline-formula><mml:math id="M1" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>L is presented. The pH monitoring is based on the color
changing effect of pH indicators. The optode includes an RGB color sensor
patch TCS34725 from Adafruit, a controllable LED and reactor slides and is
addressed by a self-written LabVIEW<sup>©</sup> software.
Utilizing the hue value of the HSV color model, it is possible to analyze the
color change of the indicator and estimate the pH value of the analyzed
samples by exploiting sigmoidal fit models. Measurements carried out with
phenol red and DMEM (Dulbecco's Modified Eagle's Medium) reported a standard
error of calibration in the physiologic pH range (6.5–7.5) of <inline-formula><mml:math id="M2" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>0.04 pH
units.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p>A new approach to fermentation-based bioreactors is the constant
miniaturization of bioreactors in the framework of personalized medical care
or high-throughput screenings. Such small-scale devices pose great
challenges for packaging and
interconnection technology and more so for sensor
technologies in terms of monitoring cell vitality. The continuous monitoring
of cell vitality parameters such as pH, pO<inline-formula><mml:math id="M3" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and pCO<inline-formula><mml:math id="M4" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> are most essential
<xref ref-type="bibr" rid="bib1.bibx29 bib1.bibx28" id="paren.1"/> for cell cultivation.</p>
      <p>Different setups are possible depending on the actual type of
application. In the case of pH sensors, the use of pH electrodes in
combination with reference electrodes such as Ag/AgCl are currently the state of
the art. However, these electrodes are not suitable for small sample volumes
in the microliter range <xref ref-type="bibr" rid="bib1.bibx12" id="paren.2"/>. In addition, no
commercially available pH electrode could be found that is suitable for a
determination of pH within working volumes of less than 1 mL. The normal pH
measurement in laboratories is carried out with pH indicators (titration) or
pH stripes. These so-called colorimetric methods are very important for the
determination of pH in small sample volumes
<xref ref-type="bibr" rid="bib1.bibx19" id="paren.3"/>. In the past, a lot of effort has been
invested in developing novel pH sensors. In comparison to electrochemical pH
sensing, optical sensors offer a good alternative when measuring a small
dynamic range of about 2 pH units <xref ref-type="bibr" rid="bib1.bibx26" id="paren.4"/>.
Moreover, optical sensors seem to have very good properties in terms of
stability to electrical interference stability, measurement stability and quality in
extreme pH regions. They offer the possibility of remote sensing and
real-time analysis <xref ref-type="bibr" rid="bib1.bibx23" id="paren.5"/>. Further advantages are the lack of
a need for a reference element and the possibility of low-cost, autoclavable
and precalibrated sensor patches <xref ref-type="bibr" rid="bib1.bibx2" id="paren.6"/>.
In addition to these advantages, developments in electronics, material
science and computer technologies as well as the increasing number of
inexpensive optical components and the wide range of synthetic reagents for
colorimetric systems have pushed research in the field of optical-based pH
sensors enormously <xref ref-type="bibr" rid="bib1.bibx13" id="paren.7"/>. Besides all these
efforts, there is still a high demand for low-cost, selective and real-time
monitoring systems to determine pH values <xref ref-type="bibr" rid="bib1.bibx15" id="paren.8"/>, which
combines all of these attributes.</p>
      <p>The measurement principles of optodes are well suited to overcome the
challenges of monitoring small sample volumes. According to the current
literature in the field of optical pH sensing, a broad range of applications,
measurement techniques and pH indicators are under development
<xref ref-type="bibr" rid="bib1.bibx14" id="paren.9"/>. Measurement techniques are mainly focused on the
utilization of UV–VIS spectra, fluorescence lifetimes and colorimetric
measurements. On the basis of the individual measurement technique, a special
indicating element is chosen such as chemicals or physical phenomena. Some
chemicals for example change their color when encountering different pH
values (pH indicators) while other substances exhibit fluorescent properties.
These chemicals have to come into contact with the sample to give information
about the respective pH value. Therefore, different immobilization techniques
are used to specify the area and time of contact between indicating
chemicals and the sample itself. Moreover, the immobilization technique and
the chosen measurement technique determine the field of use for the
developed pH optodes. The utilization of indicators entrapped in membranes or
the use of fiber optics coated with indicating elements are only a small
scope of the research done in the field of pH sensing optodes. A simplified
concept of optodes in general is displayed in Fig. <xref ref-type="fig" rid="Ch1.F1"/>.
The light-emitting source can vary from high-power lasers to specifically
colored LEDs or common white LEDs with a very broad spectral range. In most
cases, the spectra are sharpened with the aid of monochromatic filters before
reaching the sample. Within the sample, specific effects like absorbance
<xref ref-type="bibr" rid="bib1.bibx11" id="paren.10"/>, fluorescence <xref ref-type="bibr" rid="bib1.bibx25" id="paren.11"/> or
phosphorescent emission may occur. These effects are used in many research
approaches as sensing elements. Additionally, evanescence-field measurements
can also be used for optode concepts <xref ref-type="bibr" rid="bib1.bibx6" id="paren.12"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><caption><p>Sketch of the components of a simplified optode concept.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f01.png"/>

      </fig>

      <p>The aim of this research is the development of a non-destructive, contact-free and cost-effective pH optode for samples with working volumes
less than 150 <inline-formula><mml:math id="M5" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>L. Therefore, a sensor system based on transmitted light is
developed, which can be easily used for micro-structured microfluidic
arrangements. The presented pH optode determines the color change of phenol
red (PhR), bromothymol blue (BTB) and Dulbecco's Modified Eagle's Medium (DMEM) depending on different pH values.</p>
      <p><xref ref-type="bibr" rid="bib1.bibx17" id="text.13"/> presented a possibility to
determine the pH with nanoliter volumes within a microfluidic cell culture
system. They used a standard laboratory microscope combined with a
scientific-grade digital camera and two band-pass filters. In comparison to
our prototype, they achieved very good signals in a complectly
different quantity of working volume but with a more expensive and complex
setup.</p>
      <p><xref ref-type="bibr" rid="bib1.bibx1" id="text.14"/> reported a pH monitoring system for
100 <inline-formula><mml:math id="M6" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>L samples in a 384-well plate using a digital camera. The
captured RGB values of the pictures are converted into HSV or HSL color
space. As shown in this paper, an optical approach for the determination of
pH values can be versatile, efficient and provide a new method of
application. Nevertheless, a similar yet different approach is reported,
which is primarily focused on the use of more cost-effective sensor elements
and a smaller footprint size. The use of membranes doped with indicators or
fiber optics coated with indicating elements such as those reported by
<xref ref-type="bibr" rid="bib1.bibx16" id="text.15"/> are not sufficient for the aimed approach,
due to problems in biofouling and cross contamination of the cells with the
contact area. <xref ref-type="bibr" rid="bib1.bibx20" id="text.16"/> worked in parallel to this
report on a quite similar approach for a non-contact real-time pH
measurement system. In contrary to the used RGB sensor patches, Rajan et al. (2016)
established a transmission-based LED as light source and a specific
photodiode to obtain a spectra of a specific wavelength. They were
also able to achieve a small footprint with an easy
integration in different cell culture systems.</p>
</sec>
<sec id="Ch1.S2">
  <title>Experimental setup</title>
      <p>PhR (0.04 g, P3532 Sigma-Aldrich) was dissolved in 1.13 mL of NaOH
(0.1 <inline-formula><mml:math id="M7" display="inline"><mml:mi mathvariant="normal">M</mml:mi></mml:math></inline-formula>) and filled with purified water up to 100 mL. The stock
solution of BTB was made by diluting 0.1009 <inline-formula><mml:math id="M8" display="inline"><mml:mi mathvariant="normal">g</mml:mi></mml:math></inline-formula> of the
reagent in 20 mL of EtOH and filled with deionized H<inline-formula><mml:math id="M9" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O up to 100 mL.</p>
      <p>Measurements were accomplished with sodium–potassium phosphate buffers
(SPPBs) in different concentrations to get a stable array of pH values
ranging from 5 to 8 in 0.1 pH steps. The pH indicators and the specific
SPPBs were mixed in different dilutions. All applied pH values were observed
with a pH electrode (Mettler Toledo InLab 490) in a 10 mL solution of each
sample. Then, 150 <inline-formula><mml:math id="M10" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>L of each solution was spread into each of the
eight micro-bioreactor mock-ups on the polycarbonate
slide as shown in Fig. <xref ref-type="fig" rid="Ch1.F2"/>.</p>
      <p>Furthermore, experimental results using DMEM (Dulbecco's Modified Eagle's
Medium, Thermo-Fisher Scientific, catalog number: 11965092) are reported. For
these experiments, pH shifts were achieved by adding HCl to the DMEM.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><caption><p>Diagram of the experimental procedure.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f02.png"/>

      </fig>

</sec>
<sec id="Ch1.S3">
  <title>Results</title>
<sec id="Ch1.S3.SS1">
  <title>Prototype</title>
      <p>For transmittance measurements of pH dependent color changing effects of
PhR and BTB, the light is directly passing through the
sample. Therefore, a light source is placed underneath the sample and the
light is collected by the RGB sensor patch. The idea was initially visualized
in a CAD sketch as shown in Fig. <xref ref-type="fig" rid="Ch1.F3"/>, and later manufactured by rapid prototyping
via micro-milling and 3-D printing. This approach leads to a very cost-effective measurement system,
which in general depends only on the RGB sensor and a control board, e.g., an
Arduino Uno board. The expenses for both of these parts is in total EUR 30.
Further costs only arise depending on the framework used around these two
parts. For this prototype, the overall costs were less than EUR 50.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><caption><p>CAD explosion sketch of the optode: (i) base
layer for better handling and a solid positioning, (ii) reactor mock-up
placed on top of the slide, (iii) placeholder for reactor mock-ups with
different thicknesses, (iv) top layer and (v) RGB sensor and an incorporated
lens.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f03.png"/>

        </fig>

      <p>The manufactured prototype is shown in Fig. <xref ref-type="fig" rid="Ch1.F4"/>. Within the
figure a simple sketch is included, which illustrates the working principle
and the adaption of this prototype in comparison to the common optode
concepts shown in Fig. <xref ref-type="fig" rid="Ch1.F1"/>. As mentioned before, optodes
usually contain modified fiber optics or membrane technologies and
monochromatic filters. Within this prototype none of these techniques are
required. Instead of changing the geometrical dimension of the micro-bioreactors to implement membranes or fiber optics, the pH indicators are
already included in the nutrition media and thus can be utilized to measure
the pH. Secondly, no additional monochromatic filter is necessary since the
RGB unit has chromatic filters on top of the respective photodiodes.</p>
      <p>The LED originally mounted close to the top of the RGB detection unit
(Fig. <xref ref-type="fig" rid="Ch1.F4"/>a) was desoldered, incorporated underneath the
sample holder as indicated in Fig. <xref ref-type="fig" rid="Ch1.F4"/>c and reconnected
electrically with the RGB sensor via small wires. Data acquisition and
the control of the light source was achieved by an
Arduino<sup>©</sup> micro-controller. The user interface
and the data storage were created using a
LabVIEW<sup>©</sup> program.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><caption><p>Picture of the prototype for transmitted light measurements consisting of
<bold>(a)</bold> RGB detection unit, <bold>(b)</bold> a sample holder and
<bold>(c)</bold> a LED. The diagram on the right shows the measurement principle.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f04.png"/>

        </fig>

      <p>The basic idea behind the colorimetric measurement with the RGB sensor is
shown in Fig. <xref ref-type="fig" rid="Ch1.F5"/> for the example of PhR. In
acidic pH regions (<inline-formula><mml:math id="M11" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 6) PhR indicates the pH through a yellow color.
Following chromatic rules, high signals of green, less of red and least of
blue are expected. In near-neutral pH regions, PhR changes the color
from yellow to orange because the amount of protonated PhR increases.
Thus, the RGB unit should measure decreasing signals of green and increasing signals of red and blue. With even higher pH values of more than
7.3 the protonated form of PhR dominates and gives the solution a
magenta shade with a tendency towards red. The signals detected should change
to high amounts of red and blue and very low amounts of green. In
consideration of the explained example, the transformed hue values for PhR and additionally for BTB are summarized in
Table <xref ref-type="table" rid="Ch1.T1"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><caption><p>Diagram for the measurement principle of the transmitted light
prototype with the color changing effect of PhR and the corresponding red,
green and blue signals.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f05.png"/>

        </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><caption><p>Estimated color angles of BTB (bromothymol blue) and PhR (phenol red)
in different pH values based on the HSV color space model with hue values
in brackets indicating the corresponding negative hue value.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="right"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">pH</oasis:entry>  
         <oasis:entry colname="col2">PhR color</oasis:entry>  
         <oasis:entry colname="col3">PhR hue</oasis:entry>  
         <oasis:entry colname="col4">BTB color</oasis:entry>  
         <oasis:entry colname="col5">BTB hue</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">(<inline-formula><mml:math id="M12" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">(<inline-formula><mml:math id="M13" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">4</oasis:entry>  
         <oasis:entry colname="col2">yellow/red</oasis:entry>  
         <oasis:entry colname="col3">60</oasis:entry>  
         <oasis:entry colname="col4">yellow/green</oasis:entry>  
         <oasis:entry colname="col5">70</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">7–8</oasis:entry>  
         <oasis:entry colname="col2">orange</oasis:entry>  
         <oasis:entry colname="col3">30</oasis:entry>  
         <oasis:entry colname="col4">green/cyan</oasis:entry>  
         <oasis:entry colname="col5">140</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">10</oasis:entry>  
         <oasis:entry colname="col2">magenta</oasis:entry>  
         <oasis:entry colname="col3">300 (<inline-formula><mml:math id="M14" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">60</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col4">blue</oasis:entry>  
         <oasis:entry colname="col5">240</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p>Different measurements with various concentrations of PhR and
BTB were carried out. BTB was used as a control
chemical for evaluation purposes. Furthermore, experiments containing nutrition
media were carried out and will be presented in Sect. <xref ref-type="sec" rid="Ch1.S3.SS6"/>.</p>
      <p>The following data show sigmoidal shaped functions, which is a result of the
color change of indicators. This can be either related to changes of the pH
value <xref ref-type="bibr" rid="bib1.bibx2" id="paren.17"/> or to concentrations of specific analytes
<xref ref-type="bibr" rid="bib1.bibx9" id="paren.18"/>. In general, the data fitting can be achieved with
different sigmoidal models such as the Boltzmann equation, the logistic
equation or the Hill function. However, within this work the fittings were
achieved with the dose-response equation utilized by programs like Origin or
R. A modified dose-response equation containing a hill slope coefficient
showed the best fitting results regarding the least root-square sum and the
double standard deviation (<inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">σ</mml:mi></mml:mrow></mml:math></inline-formula>).</p>
      <p>Two different models were used to describe the sigmoidal shaped function of
PhR (Eq. <xref ref-type="disp-formula" rid="Ch1.E1"/>) and BTB
(Eq. <xref ref-type="disp-formula" rid="Ch1.E2"/>).</p>
      <p><disp-formula specific-use="align" content-type="numbered"><mml:math id="M16" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E1"><mml:mtd/><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mi>H</mml:mi><mml:mtext>Sig</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>(</mml:mo><mml:mtext>pH</mml:mtext><mml:mo>-</mml:mo><mml:msub><mml:mtext>pK</mml:mtext><mml:mi>a</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mi mathvariant="italic">α</mml:mi></mml:mrow></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E2"><mml:mtd/><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>H</mml:mi><mml:mtext>Sig</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>(</mml:mo><mml:msub><mml:mtext>pK</mml:mtext><mml:mi>a</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:mtext>pH</mml:mtext><mml:mo>)</mml:mo><mml:mi mathvariant="italic">α</mml:mi></mml:mrow></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            <inline-formula><mml:math id="M17" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M18" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are the respective hue values for the top
and bottom plateau, <inline-formula><mml:math id="M19" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>Sig</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the measured hue value given for a specific
pH value, <inline-formula><mml:math id="M20" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is used to describe the slope steepness (hill coefficient)
and pK<inline-formula><mml:math id="M21" display="inline"><mml:msub><mml:mi/><mml:mi>a</mml:mi></mml:msub></mml:math></inline-formula> is the logarithmic acid dissociation constant of the indicator used.</p>
      <p>On the basis of this mathematical approach, the calibration data, and thus the
pH value, depend on four different parameters, which have to be fitted
first. <inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M23" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> should be determined experimentally
at very high and low pH values because they indicate the maximum of the
protonated and deprotonated form of the indicator used. It is said that most
common indicators reach their respective maximum and minimum at about
pH <inline-formula><mml:math id="M24" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> pK<inline-formula><mml:math id="M25" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub><mml:mo>±</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>
<xref ref-type="bibr" rid="bib1.bibx10 bib1.bibx27 bib1.bibx3" id="paren.19"/>.
Therefore, all experiments were carried out in a pH range from 4 to 10 to
fulfill these requirements for both PhR and BTB.</p>
      <p>Although the pK<inline-formula><mml:math id="M26" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula> is commonly said to be constant, it depends on
temperature, ionic strength and the solvent dielectric constant
<xref ref-type="bibr" rid="bib1.bibx21" id="paren.20"/>. PhR changes its color from
yellow to magenta/red in the pH range between 6.4 and 8.2 with a
pK<inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">7.4</mml:mn></mml:mrow></mml:math></inline-formula>–7.9 <xref ref-type="bibr" rid="bib1.bibx22 bib1.bibx24" id="paren.21"/>.
The color change of BTB appears at the limits of pH in between
approximately 5.8 and 7.6 with a pK<inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">7.1</mml:mn></mml:mrow></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx8 bib1.bibx4" id="paren.22"/>.
Taking this into account, the pK<inline-formula><mml:math id="M29" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula> value is one of two parameters
needed to be fitted mathematically. The second parameter is the so-called
hill slope coefficient <inline-formula><mml:math id="M30" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> (often referred as <inline-formula><mml:math id="M31" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>,
<xref ref-type="bibr" rid="bib1.bibx5" id="altparen.23"/>, or <inline-formula><mml:math id="M32" display="inline"><mml:mi>d</mml:mi></mml:math></inline-formula>,
<xref ref-type="bibr" rid="bib1.bibx7" id="altparen.24"/>).</p>
      <p>Considering the different approaches of pK<inline-formula><mml:math id="M33" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula> and <inline-formula><mml:math id="M34" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>, these parameters have
to be fitted within a calibration. Thus, the mathematical model is fitted on
the experimental data based on the method of the least root-square sum
without weighting as shown in Eq. (<xref ref-type="disp-formula" rid="Ch1.E4"/>):

                <disp-formula specific-use="align" content-type="numbered"><mml:math id="M35" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E3"><mml:mtd/><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mtext>Distance</mml:mtext></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mo>=</mml:mo><mml:mo movablelimits="false">∑</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:msub><mml:mtext>Y</mml:mtext><mml:mtext>Data</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mtext>Y</mml:mtext><mml:mtext>Curve</mml:mtext></mml:msub></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E4"><mml:mtd/><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mtext>RSS</mml:mtext></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mo>=</mml:mo><mml:msqrt><mml:mtext>Distance</mml:mtext></mml:msqrt><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            where RSS is the root-square sum, <inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:msub><mml:mi>Y</mml:mi><mml:mtext>Data</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the measured hue value
and <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:msub><mml:mi>Y</mml:mi><mml:mtext>Curve</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the hue value calculated with the model
<xref ref-type="bibr" rid="bib1.bibx18" id="paren.25"/>. The fitting itself is done by the solver
function of MS Excel using the GRG-solver algorithm. This algorithm changes
the pK<inline-formula><mml:math id="M38" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula> and <inline-formula><mml:math id="M39" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> values starting at pK<inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">7.1</mml:mn></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> to minimize the RSS value. As long as the pK<inline-formula><mml:math id="M42" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula> is within
a range of 7 to 8 and <inline-formula><mml:math id="M43" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is within a range between 0.85 and 1.5,
the data were determined to be fitted well.</p>
</sec>
<sec id="Ch1.S3.SS2">
  <?xmltex \opttitle{Phenol red (PhR) 1\,:\,10 in SPPB}?><title>Phenol red (PhR) 1 : 10 in SPPB</title>
      <p>Regarding the data shown in Fig. <xref ref-type="fig" rid="Ch1.F6"/>, the measured color
angle of PhR ranges from <inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mi>H</mml:mi><mml:mo>∼</mml:mo><mml:msup><mml:mn mathvariant="normal">40</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> at pH <inline-formula><mml:math id="M45" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 2 to
<inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:mi>H</mml:mi><mml:mo>∼</mml:mo><mml:mo>-</mml:mo><mml:msup><mml:mn mathvariant="normal">7</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> at pH <inline-formula><mml:math id="M47" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 11. Therefore, PhR should be
yellow with a slightly red shift in alkaline pH regions, whereas it
should be red with a tendency to magenta in acidic pH regions. Observations
with the naked eye estimated hue values between 60<inline-formula><mml:math id="M48" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> (yellow) and
<inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">40</mml:mn></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="M50" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> (magenta, slightly red shifted). Although these data display a
discrepancy between estimated (shown in Table <xref ref-type="table" rid="Ch1.T1"/>)
and measured signals, the fitting results show stable measurement results.
However, in acidic pH regions the discrepancy is quiet significant. The hue
value in basic pH regions implies a strong red color, whereas the observable
color contains much more magenta. This effect can be explained with an
existing effect of the LED on the measurement. Therefore, two different
experiments were carried out to validate this effect. First the concentration
of PhR was increased to achieve a higher interaction between
the dye and the light. Secondly, the hue of the LED without any dye included
was determined.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><caption><p>Hue data (mean value of 10 measurements) depending on
pH values. PhR diluted in a ratio of 1 : 10 in SPPB. The fitting parameters are the following: pK<inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">7.13</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.20</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">4.55</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f06.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS3">
  <?xmltex \opttitle{Phenol red 1\,:\,5 in SPPB}?><title>Phenol red 1 : 5 in SPPB</title>
      <p>A PhR : SPPB ratio of 1 : 5 was chosen to be measured using the developed
prototype. The results, in the form of hue values, are shown in
Fig. <xref ref-type="fig" rid="Ch1.F7"/>. The included error bars indicate the double standard
deviation of the distance between the measured hue and the fitted data point.
Within these results a double standard deviation of 1.5<inline-formula><mml:math id="M54" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> was
achieved. In comparison to the data shown before, a higher accuracy was
obtained with a higher concentration of the indicator. This is basically
induced by the stronger color which enables a higher level of light–matter
interaction. An increase in excited indicator molecules consequently results
in more distinct hue values. Additionally, the influence of the LED is
decreased, because reduced non-interacted light emitted by the LED shines
through the sample. Although the H<inline-formula><mml:math id="M55" display="inline"><mml:msub><mml:mi/><mml:mtext>max</mml:mtext></mml:msub></mml:math></inline-formula> value obtained is nearly the
same, <inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is different with <inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:msup><mml:mn mathvariant="normal">19.02</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>.
This hue value still displays a discrepancy to the expected hue value of about
<inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:msup><mml:mn mathvariant="normal">40</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, but shows a far better tendency towards magenta. Considering this information, a change of the concentration of PhR did not result
in a change of the maximum hue value, but resulted in a change of the obtained
minimum.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><caption><p>Hue data (mean value of 10 measurements) depending on
pH values measured in a single chamber. PhR diluted in a ratio of
1 : 5 in SPPB. The fitting parameters are the following:
pK<inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">7.43</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.04</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">1.21</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f07.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS4">
  <title>Influence of the LED</title>
      <p>Different hue measurements of PhR imply a possible influence of the
LED on these measurements. For evaluation purposes, the color angle of the
used LED was obtained and compared with hue values measured in two different
PhR concentrations. The results of this experiment are reported in
Fig. <xref ref-type="fig" rid="Ch1.F8"/>. In fact, the hue value of the LED (<inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:mi>H</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">34.33</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) and the hue values of PhR in very acidic pH regions
(<inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>:</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">10</mml:mn><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">37.57</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>:</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">5</mml:mn><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">38.04</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) are very similar to each other. Currently, the results seem
to indicate that the difference within acidic pH regions is not
significantly influenced by a higher concentration of PhR. In contrast to the acidic pH regions, the difference between the color of the LED and the
color of PhR in alkaline pH regions (<inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>:</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">10</mml:mn><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:msup><mml:mn mathvariant="normal">7.83</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>:</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">5</mml:mn><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:msup><mml:mn mathvariant="normal">19.02</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) is much higher, and
the hue values of the two PhR concentrations vary from each other.
PhR has an absorbance maximum in the wavelength region of yellow light
between 550 and 580 <inline-formula><mml:math id="M67" display="inline"><mml:mi mathvariant="normal">nm</mml:mi></mml:math></inline-formula>. With increasing pH
values, more yellow light of the LED is absorbed, which results in
the color change from yellow to magenta. Due to this absorption
characteristic of PhR, the difference of the hue value between the LED
and PhR in acidic pH regions is not influenced by the concentration of
the dye. However, the effect of the absorbance of yellow light is
much higher within alkaline pH regions and therefore dependent on the
concentration.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8"><caption><p>Direct comparison of the results of PhR : SPPB with ratios 1 : 10 and
1 : 5. Hue value of the LED and the probable
influence of the LED on the results are indicated by the black arrow.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f08.png"/>

        </fig>

      <p>In addition to the effect caused by the color spectrum of the LED,
the position of the LED with respect to the sample is said to have a high
influence on the measurement results. A matrix of pictures of PhR and
BTB (1 : 10) at pH 3 and pH 10 was made and is shown in
Fig. <xref ref-type="fig" rid="Ch1.F9"/>. To achieve this, the top layer of the second prototype
was dismounted. From the edge to the center of the chamber, the intensity of
the LED becomes stronger. This is mainly caused by the semicircular angle of
radiation of the LED, thus yielding different path lengths and reflection
angles of the light, which result in a specific light cone. The nearly
unaffected light of the LED takes up about one-third of the complete chamber.
Despite that, the experimental results show stable and reproducible signal
sequences.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9"><caption><p>Pictures of the LED shining through the reactor mock-up filled with
PhR <bold>(a, b)</bold> and BTB <bold>(c, d)</bold> in pH 3 (Left column) and pH 10 (right column). Pictures were taken from
above while the RGB sensor of prototype II was dismounted.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f09.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS5">
  <title>Bromothymol blue (BTB)</title>
      <p>For a better comparison of the effect of different concentrations of BTB in
SPPB, the results for two different dilution ratios are reported within one
diagram shown in Fig. <xref ref-type="fig" rid="Ch1.F10"/>. Both curves for <inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:mi>H</mml:mi><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>:</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mn mathvariant="normal">10</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M69" display="inline"><mml:mrow><mml:mi>H</mml:mi><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>:</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">5</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> share almost the same lower limit of
<inline-formula><mml:math id="M70" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>:</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mn mathvariant="normal">10</mml:mn><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">32.24</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>:</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">5</mml:mn><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">29.93</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. Additionally, the maximum
plateaus with <inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>:</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mn mathvariant="normal">10</mml:mn><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">221.51</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>:</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">5</mml:mn><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">226.38</mml:mn><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> are also nearly the same. The main
parts of the curves are mostly identical, although a small difference can be
seen.</p>
      <p>Conversely to the initial assumption and comparing these results with the
results of different concentrations of PhR, no differences between the
two used concentrations of BTB were obtained. One possible
explanation could be that both of the utilized BTB concentrations
already show the maximum of the obtainable signals. In conclusion, BTB can be diluted even further in comparison to PhR because even
with a dilution ratio of 1 : 10 the solution is still saturated with
BTB. Therefore, BTB is more suitable for pH monitoring in even
smaller micro-reactors in comparison to PhR. Only very small
deviations are detected for the two dilutions of 1 : 10 and
1 : 5 in Fig. <xref ref-type="fig" rid="Ch1.F10"/>. These minor deviations are due to the mechanical manufacturing of the chambers resulting in slightly
different surfaces (flatness, roughness, micro-scratches etc.) and the
subsequent different optical properties of the chambers (transparency,
scattering etc.). In the case of industrial manufacturing routines, even such small differences may be
eliminated resulting in very precise determinations for the pH values.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10"><caption><p>Hue data (mean value of 10 measurements) depending on
pH values measured in the same chamber. BTB diluted in ratios
of 1 : 10 and 1 : 5 in SPPB. Fitting parameters are the following:
pK<inline-formula><mml:math id="M74" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula>(1 : 10) <inline-formula><mml:math id="M75" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 6.99, <inline-formula><mml:math id="M76" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>(1 : 10) <inline-formula><mml:math id="M77" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1.53,
<inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">σ</mml:mi></mml:mrow></mml:math></inline-formula>(1 : 10) <inline-formula><mml:math id="M79" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 2.97<inline-formula><mml:math id="M80" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>, pK<inline-formula><mml:math id="M81" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula>(1 : 5) <inline-formula><mml:math id="M82" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 6.96,
<inline-formula><mml:math id="M83" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>(1 : 5) =1.46 and <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">σ</mml:mi></mml:mrow></mml:math></inline-formula>(1 : 5) <inline-formula><mml:math id="M85" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 4.32<inline-formula><mml:math id="M86" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f10.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS6">
  <title>Nutrition media</title>
      <p>Results reported beforehand were aiming for a characterization of PhR
and BTB in pH ranging from about 3 to 10. Nevertheless,
the following section is more focused on a defined pH range from pH <inline-formula><mml:math id="M87" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 4
to pH <inline-formula><mml:math id="M88" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 7.5. During cell culture, it is very uncommon for the solution to
become alkaline. In most cases, dying cells produce specific acids
which change the pH value of the nutrition media towards lower pH.
Taking this into account, the non-diluted DMEM nutrition media with a basis
pH of about 7.5 is used as the starting point. By using 1 <inline-formula><mml:math id="M89" display="inline"><mml:mi mathvariant="normal">M</mml:mi></mml:math></inline-formula> HCl,
the pH values were set to acidic pH ranges. But conversely to pure PhR and BTB, the nutrition media is a far more complex solution.
Besides different salts, liquids and nutrients such as glucose, it contains a
pH buffer system to stabilize the pH in certain ranges for a better cell
growth. The DMEM used has a sodium bicarbonate buffer included. This buffer
system leads to a rising bubble formation within the solution at low pH
values. These bubbles are caused by CO<inline-formula><mml:math id="M90" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, which is produced during the
following chemical reaction:
            <disp-formula id="Ch1.Ex1"><mml:math id="M91" display="block"><mml:mrow><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NaHCO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:mi mathvariant="normal">HCl</mml:mi></mml:mrow><mml:mo>→</mml:mo><mml:mrow class="chem"><mml:mi mathvariant="normal">NaCl</mml:mi></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>A good example for this chemical reaction can be found within the human
digestive system. However, within very small working volumes of
100–150 <inline-formula><mml:math id="M92" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>L, these bubbles can have a high influence on the
measured hue value because of additional scattering effects and local changes
of the dye concentration.</p>
      <p>The hue data of four different chambers are reported in
Fig. <xref ref-type="fig" rid="Ch1.F11"/>. The curve has to be read from the near-neutral pH
value backwards to the acidic pH range. With each experimental step, more HCl
was added and therefore, the pH value shifted from 7.5 to 4. It was not
possible to obtain any kind of usable data if nutrition media and HCl were
pipetted together within the 150 <inline-formula><mml:math id="M93" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>L chambers. The CO<inline-formula><mml:math id="M94" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> bubbles
developing within the chamber had a strong negative influence on the
measurements. Therefore, the pH was set in a beaker glass containing the
stock solution of the nutrition media by adding small amounts of HCl. The
developing bubbles were stirred out within this beaker glass. Meanwhile, the
pH value is controlled with a pH glass electrode. After specific pH values
were reached, the solution was taken from the beaker glass into specific
reactor mock-up chambers. Although most of the evolving gas was stirred out,
it was not possible to release all of the bubbles. The remaining CO<inline-formula><mml:math id="M95" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> bubbles were
expected to have a high influence. However, no significant additional
scattering was detected.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11"><caption><p>Hue data (mean value of 10 measurements) of non-diluted nutrition
media as a function of pH values measured in four different
chambers at once.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://jsss.copernicus.org/articles/6/351/2017/jsss-6-351-2017-f11.png"/>

        </fig>

      <p>Although just small amounts of PhR are included within the used DMEM,
the reported data display a high accuracy and stability within the hue value.
The color change of PhR can be detected as a function of the pH.</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <title>Conclusions</title>
      <p>This prototype was designed and manufactured as a transmission setup using an
RGB color sensor patch to observe the color change of specific pH indicators.
While the RGB data already achieved good results, an even greater improvement
was obtained by utilizing the HSV color space. Therefore, the red, green and
blue signals were transformed into the hue value, which had two major
benefits. On the one hand, the hue value is a perception-based color model
and simplifies the signal estimation. Therefore, it is easier to compare the
measured data with the real data. On the other hand, the hue value showed
better results in terms of stability and accuracy. The accuracy was measured
with the double standard deviation of the differences between fitted curve
and real measurement data. This very robust fitting procedure, which used
<inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, the pK<inline-formula><mml:math id="M98" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula> value and the <inline-formula><mml:math id="M99" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>
coefficient, can be adapted for different pH indicator dyes. The values for
<inline-formula><mml:math id="M100" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are determined experimentally, while
pK<inline-formula><mml:math id="M102" display="inline"><mml:msub><mml:mi/><mml:mtext>a</mml:mtext></mml:msub></mml:math></inline-formula> and <inline-formula><mml:math id="M103" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> are fitted mathematically.</p>
      <p>The validation of this prototype included two pH indicator dyes. These were
analyzed under different conditions, such as changes in concentration. PhR was used with two different concentrations: 113 <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> (1 : 10)
and 226 <inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> (1 : 5).</p>
      <p>Further validation experiments were carried out using BTB
with concentrations of 161 <inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> (1 : 10) and 322 <inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula>
(1 : 5). Conversely to PhR, BTB changes the color
from yellow (acidic) to blue (alkaline) and did not indicate a concentration
dependency on the hue measurement. A possible explanation was found in the
saturation of the solution with BTB.</p>
      <p>Although measurements of low PhR concentrations (11.3 <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula>,
not reported) did not result in obtainable color changes, experiments with
DMEM including similar PhR concentrations between 20 and 40 <inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> were successful. DMEM is a very complex solution
incorporating amino acids, inorganic salts and many other nutrients. These
additional components increase the amount of scattered light significantly. A
higher amount of light–matter interaction occurs due to this additional
scattering within the solution. Therefore, more PhR molecules are
excited and thus more light is absorbed.</p>
      <p>Further experiments revealed two major shortcomings when using the second
prototype to determine the pH in DMEM. On the one hand, DMEM includes a
sodium bicarbonate buffer to stabilize the cell culture, which induces the
building of CO<inline-formula><mml:math id="M110" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> with decreasing pH values. These CO<inline-formula><mml:math id="M111" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> bubbles have a
negative influence on the hue determination. Considering the use of this
system within a flow-through cell culture system for micro-sized bioreactors,
CO<inline-formula><mml:math id="M112" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> bubbles are not a relevant factor. Even if the formation of bubbles
takes place, they will be flushed out by the liquid flow. A second negative
aspect of using DMEM is based on missing data for basic (alkaline) pH regions.
The fitting procedure has the necessity for <inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>max</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, which have to be determined experimentally by using pH
calibrated standards. Normally, cells in the study of necrosis or apoptosis produce
specific acids, which lower the pH. It is very uncommon that nutrition media
during a cell culture becomes basic. Because of the imprecisely determined
<inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> value, the fitting of the data becomes more complex and more
imprecise. However, the overall system was designed as a cost-effective
easy-to-handle pH monitoring system to determine the vitality of the cells.
Therefore, no high-precision analysis of the pH is required and the system
can be used perfectly for this approach.</p>
      <p>Considering all experimental results, this prototype showed remarkable
properties in terms of signal stability and accuracy; moreover, it offers the
possibility for online measurements. In consideration of the later use of the
micro-bioreactor system, the prototype was designed to fit within micro-sized
flow-through cell culture systems. Therefore, disadvantages such as bubble
formation or missing <inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mtext>min</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> baselines have to be taken into account
in the experimental environment but are less important in the real use. The
achieved advantages of this pH optode can be found within the easy-to-handle
and very cost-effective approach. The system can be miniaturized and
incorporated into the micro-bioreactor system with less effort. Furthermore,
the calibration of the complete setup can be made for any type of pH
indicator dye, enhancing the usability of the system for a wide range of cell
culture experiments. Considering the desired precision of the pH analysis, it
is possible to enhance the accuracy of the measurement data by using light
sources with specific wavelengths, incorporating monochromatic filters and
with further improvement of the calibration standard.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability">

      <p>Data are available upon request by contacting the author Christian Rogge (rogge@th-wildau.de).</p>
  </notes><notes notes-type="competinginterests">

      <p>The authors declare that they have no conflict of
interest.</p>
  </notes><notes notes-type="sistatement">

      <p>This article is part of the special issue “Sensors and
Measurement Systems 2016”. It is a result of the 18th GMA/ITG Fachtagung
Sensoren und Messsysteme 2016, Nuremberg, Germany, 10–11 May 2016.</p>
  </notes><ack><title>Acknowledgements</title><p>We thank Analytical Control Instruments GmbH for the productive
cooperation in the ZIM Cooperation project KF2014167AK4. This project was
financially supported in the framework of the Central Innovation Programme
for SME by the AiF Projekt GmbH under the auspices of the Federal Ministry
for Economic Affairs and Energy (BMWi). <?xmltex \hack{\newline}?><?xmltex \hack{\newline}?>
Edited by: Albert Romano-Rodriguez<?xmltex \hack{\newline}?> Reviewed by: three
anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Brown et al.(2014)</label><mixed-citation>
Brown, J. D., Bell, N., Li, V., and Cantrell, K.: Quantitative pH assessment
of small-volume samples using a universal pH indicator, Anal. Biochem., 462,
29–31, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Capel-Cuevas et al.(2010)</label><mixed-citation>
Capel-Cuevas, S., Cuéllar, M., de Orbe-Payá, I., Pegalajar, M., and
Capitán-Vallvey, L.: Full-range optical pH sensor based on imaging
techniques, Anal. Chim. Acta, 681, 71–81, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Chen et al.(2010)</label><mixed-citation>
Chen, H.-X., Wang, X.-D., Song, X.H., Zhou, T.-Y., Jiang, Y.-Q., and Chen,
X.: Colorimetric optical pH sensor production using a dual-color system,
Sensor. Actuat. B-Chem., 146, 278–282, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Dean(1992)</label><mixed-citation>
Dean, J.: Lange's Handbook of Chemistry, McGraw-Hill, 14th Edn., chap. 8,
8.115–8.116, 1992.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>Di Veroli et al.(2015)</label><mixed-citation>Di Veroli, G. Y., Fornari, C., Goldlust, I., Mills, G., Koh, S. B., Bramhall,
J. L., Richards, F. M., and Jodrell, D. I.: An automated fitting procedure
and software for dose-response curves with multiphasic features, Sci.
Rep.-UK, 5, 14701, <ext-link xlink:href="https://doi.org/10.1038/srep14701" ext-link-type="DOI">10.1038/srep14701</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Flannery et al.(1997)</label><mixed-citation>
Flannery, D., James, S. W., Tatam, R. P., and Ashwell, G. J.: pH sensor using
Langmuir–Blodgett overlays on polished optical fibers, Opt. Lett., 22,
567–569, 1997.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Gadagkar and Call(2015)</label><mixed-citation>
Gadagkar, S. R. and Call, G. B.: Computational tools for fitting the Hill
equation to dose–response curves, J. Pharmacol. Toxicol., 71, 68–76, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Jeffery et al.(1991)</label><mixed-citation>
Jeffery, G. H., Bassett J., Mendham, J., and Denney, R. C.: Vogel's Textbook
of Quantitative Chemical Analysis, Wiley, 668–670, 1991.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Hong and Chang(2014)</label><mixed-citation>
Hong, J. I. and Chang, B.-Y.: Development of the smartphone-based colorimetry
for multi-analyte sensing arrays, Lab Chip, 14, 1725–1732, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Jander(1933)</label><mixed-citation>
Jander, G.: Die colorimetrische und potentiometrische PH-Bestimmung, Angew.
Chem.-Ger. Edit., 46, 83–83, 1933.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Jin et al.(2000)</label><mixed-citation>
Jin, Z., Su, Y., and Duan, Y.: An improved optical pH sensor based on
polyaniline, Sensor. Actuat. B-Chem., 71, 118–122, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Kick and Mertig(2015)</label><mixed-citation>
Kick, A. and Mertig, M.: Characterization of pH-sensitive polymer layers by
surface plasmon resonance and quartz crystal microbalance, Phys. Status
Solidi A, 212, 1249–1253, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Lau et al.(2004)</label><mixed-citation>
Lau, K. T., Baldwin, S., Shepherd, R. L., Dietz, P. H., Yerzunis, W. S., and
Diamond, D.: Novel fused-LEDs devices as optical sensors for colorimetric
analysis, Talanta, 63, 167–173, 2004.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Lin(2000)</label><mixed-citation>
Lin, J.: Recent development and applications of optical and fiber-optic pH
sensors, TRAC-Trend Anal. Chem., 19, 541–552, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx15"><label>Liu et al.(2014)</label><mixed-citation>
Liu, L., Guo, P., Chai, L., Shi, Q., Xu, B., Yuan, J., Wang, X., Shi, X., and
Zhang, W.: Fluorescent and colorimetric detection of pH by a rhodamine-based
probe, Sensor. Actuat. B-Chem., 194, 498–502, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>Maclin et al.(2015)</label><mixed-citation>
Maclin, A. Q., Kim, M. D., Dergunov, S. A., Pinkhassik, E., and Lindner, E.:
Small-Volume pH Sensing with a Capillary Optode Utilizing Dye-Loaded Porous
Nanocapsules in a Hydrogel Matrix, Electroanalysis, 27, 733–744, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Magnusson et al.(2013)</label><mixed-citation>
Magnusson, E. B., Halldorsson, S., Fleming, R. M., and Leosson, K.: Real-time
optical pH measurement in a standard microfluidic cell culture system,
Biomed. Opt. Express, 4, 1749–1758, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>Motulsky and Christopoulos(2004)</label><mixed-citation>
Motulsky, H. and Christopoulos, A.: Fitting models to biological data using
linear and nonlinear regression: a practical guide to curve fitting, OUP USA,
2004.</mixed-citation></ref>
      <ref id="bib1.bibx19"><label>Offenbacher et al.(1986)</label><mixed-citation>
Offenbacher, H., Wolfbeis, O. S., and Fürlinger, E.: Fluorescence optical
sensors for continuous determination of near-neutral pH values, Sensor.
Actuat., 9, 73–84, 1986.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Rajan et al.(2016)</label><mixed-citation>
Rajan, D. K., Patrikoski, M., Verho, J., Sivula, J., Ihalainen, H.,
Miettinen, S., and Lekkala, J.: Optical non-contact pH measurement in cell
culture with sterilizable, modular parts, Talanta, 161, 755–761, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx21"><label>Reijenga et al.(2013)</label><mixed-citation>
Reijenga, J., Van Hoof, A., Van Loon, A., and Teunissen, B.: Development of
methods for the determination of pKa values, Anal. Chem. Insights, 8, 53–71,
2013.</mixed-citation></ref>
      <ref id="bib1.bibx22"><label>Robert-Baldo et al.(1985)</label><mixed-citation>
Robert-Baldo, G. L., Morris, M. J., and Byrne, R. H.: Spectrophotometric
determination of seawater pH using phenol red, Anal. Chem., 57, 2564–2567,
1985.</mixed-citation></ref>
      <ref id="bib1.bibx23"><label>Safavi and Bagheri(2003)</label><mixed-citation>Safavi, A. and Bagheri, M.: Novel optical pH sensor for high and low pH
values, Sensor. Actuat. B-Chem., 90, 143–150, 2003.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bibx24"><label>Salk et al.(1954)</label><mixed-citation>
Salk, J. E., Youngner, J., and Ward, E. N.: Use of color change of phenol red
as the indicator in titrating poliomyelitis virus or its antibody in a
tissue-culture system, Am. J. Hyg., 60, 214–30, 1954.</mixed-citation></ref>
      <ref id="bib1.bibx25"><label>Song et al.(1997)</label><mixed-citation>
Song, A., Parus, S., and Kopelman, R.: High-performance fiber-optic pH
microsensors for practical physiological measurements using a dual-emission
sensitive dye, Anal. Chem., 69, 863–867, 1997.</mixed-citation></ref>
      <ref id="bib1.bibx26"><label>Stahl et al.(2006)</label><mixed-citation>
Stahl, H., Glud, A., Schröder, C. R., Klimant, I., Tengberg, A., and
Glud, R. N.: Time-resolved pH imaging in marine sediments with a luminescent
planar optode, Limnol. Oceanogr.-Meth., 4, 336–345, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx27"><label>Tucker et al.(1989)</label><mixed-citation>
Tucker, S., Robinson, R., Keane, C., Boff, M., Zenko, M., Batish, S., and
Street, K. W.: Colorimetric determination of pH, J. Chem. Educ., 66, 769 pp.,
1989.</mixed-citation></ref>
      <ref id="bib1.bibx28"><label>Weigl et al.(1994)</label><mixed-citation>
Weigl, B. H., Holobar, A., Trettnak, W., Klimant, I., Kraus, H., O'Leary, P.,
and Wolfbeis, O. S.: Optical triple sensor for measuring pH, oxygen and
carbon dioxide, J. Biotechnol., 32, 127–138, 1994.</mixed-citation></ref>
      <ref id="bib1.bibx29"><label>Yacynych et al.(1990)</label><mixed-citation>
Yacynych, A. M., Twork, J. V., and McGregor, W. C.: Sensors in bioprocess
control, Dekker New York, 1990.</mixed-citation></ref>

  </ref-list><app-group content-type="float"><app><title/>

    </app></app-group></back>
    <!--<article-title-html>Transmitted light pH optode for small sample volumes</article-title-html>
<abstract-html><p class="p">An innovative concept of a low-cost pH optode with working volumes of less
than 150 µL is presented. The pH monitoring is based on the color
changing effect of pH indicators. The optode includes an RGB color sensor
patch TCS34725 from Adafruit, a controllable LED and reactor slides and is
addressed by a self-written LabVIEW<span style="position:relative; bottom:0.5em; " class="text">©</span> software.
Utilizing the hue value of the HSV color model, it is possible to analyze the
color change of the indicator and estimate the pH value of the analyzed
samples by exploiting sigmoidal fit models. Measurements carried out with
phenol red and DMEM (Dulbecco's Modified Eagle's Medium) reported a standard
error of calibration in the physiologic pH range (6.5–7.5) of ±0.04 pH
units.</p></abstract-html>
<ref-html id="bib1.bib1"><label>Brown et al.(2014)</label><mixed-citation>
Brown, J. D., Bell, N., Li, V., and Cantrell, K.: Quantitative pH assessment
of small-volume samples using a universal pH indicator, Anal. Biochem., 462,
29–31, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Capel-Cuevas et al.(2010)</label><mixed-citation>
Capel-Cuevas, S., Cuéllar, M., de Orbe-Payá, I., Pegalajar, M., and
Capitán-Vallvey, L.: Full-range optical pH sensor based on imaging
techniques, Anal. Chim. Acta, 681, 71–81, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Chen et al.(2010)</label><mixed-citation>
Chen, H.-X., Wang, X.-D., Song, X.H., Zhou, T.-Y., Jiang, Y.-Q., and Chen,
X.: Colorimetric optical pH sensor production using a dual-color system,
Sensor. Actuat. B-Chem., 146, 278–282, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Dean(1992)</label><mixed-citation>
Dean, J.: Lange's Handbook of Chemistry, McGraw-Hill, 14th Edn., chap. 8,
8.115–8.116, 1992.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Di Veroli et al.(2015)</label><mixed-citation>
Di Veroli, G. Y., Fornari, C., Goldlust, I., Mills, G., Koh, S. B., Bramhall,
J. L., Richards, F. M., and Jodrell, D. I.: An automated fitting procedure
and software for dose-response curves with multiphasic features, Sci.
Rep.-UK, 5, 14701, <a href="https://doi.org/10.1038/srep14701" target="_blank">https://doi.org/10.1038/srep14701</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Flannery et al.(1997)</label><mixed-citation>
Flannery, D., James, S. W., Tatam, R. P., and Ashwell, G. J.: pH sensor using
Langmuir–Blodgett overlays on polished optical fibers, Opt. Lett., 22,
567–569, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Gadagkar and Call(2015)</label><mixed-citation>
Gadagkar, S. R. and Call, G. B.: Computational tools for fitting the Hill
equation to dose–response curves, J. Pharmacol. Toxicol., 71, 68–76, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Jeffery et al.(1991)</label><mixed-citation>
Jeffery, G. H., Bassett J., Mendham, J., and Denney, R. C.: Vogel's Textbook
of Quantitative Chemical Analysis, Wiley, 668–670, 1991.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Hong and Chang(2014)</label><mixed-citation>
Hong, J. I. and Chang, B.-Y.: Development of the smartphone-based colorimetry
for multi-analyte sensing arrays, Lab Chip, 14, 1725–1732, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Jander(1933)</label><mixed-citation>
Jander, G.: Die colorimetrische und potentiometrische PH-Bestimmung, Angew.
Chem.-Ger. Edit., 46, 83–83, 1933.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Jin et al.(2000)</label><mixed-citation>
Jin, Z., Su, Y., and Duan, Y.: An improved optical pH sensor based on
polyaniline, Sensor. Actuat. B-Chem., 71, 118–122, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Kick and Mertig(2015)</label><mixed-citation>
Kick, A. and Mertig, M.: Characterization of pH-sensitive polymer layers by
surface plasmon resonance and quartz crystal microbalance, Phys. Status
Solidi A, 212, 1249–1253, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Lau et al.(2004)</label><mixed-citation>
Lau, K. T., Baldwin, S., Shepherd, R. L., Dietz, P. H., Yerzunis, W. S., and
Diamond, D.: Novel fused-LEDs devices as optical sensors for colorimetric
analysis, Talanta, 63, 167–173, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Lin(2000)</label><mixed-citation>
Lin, J.: Recent development and applications of optical and fiber-optic pH
sensors, TRAC-Trend Anal. Chem., 19, 541–552, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Liu et al.(2014)</label><mixed-citation>
Liu, L., Guo, P., Chai, L., Shi, Q., Xu, B., Yuan, J., Wang, X., Shi, X., and
Zhang, W.: Fluorescent and colorimetric detection of pH by a rhodamine-based
probe, Sensor. Actuat. B-Chem., 194, 498–502, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Maclin et al.(2015)</label><mixed-citation>
Maclin, A. Q., Kim, M. D., Dergunov, S. A., Pinkhassik, E., and Lindner, E.:
Small-Volume pH Sensing with a Capillary Optode Utilizing Dye-Loaded Porous
Nanocapsules in a Hydrogel Matrix, Electroanalysis, 27, 733–744, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Magnusson et al.(2013)</label><mixed-citation>
Magnusson, E. B., Halldorsson, S., Fleming, R. M., and Leosson, K.: Real-time
optical pH measurement in a standard microfluidic cell culture system,
Biomed. Opt. Express, 4, 1749–1758, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Motulsky and Christopoulos(2004)</label><mixed-citation>
Motulsky, H. and Christopoulos, A.: Fitting models to biological data using
linear and nonlinear regression: a practical guide to curve fitting, OUP USA,
2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Offenbacher et al.(1986)</label><mixed-citation>
Offenbacher, H., Wolfbeis, O. S., and Fürlinger, E.: Fluorescence optical
sensors for continuous determination of near-neutral pH values, Sensor.
Actuat., 9, 73–84, 1986.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Rajan et al.(2016)</label><mixed-citation>
Rajan, D. K., Patrikoski, M., Verho, J., Sivula, J., Ihalainen, H.,
Miettinen, S., and Lekkala, J.: Optical non-contact pH measurement in cell
culture with sterilizable, modular parts, Talanta, 161, 755–761, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Reijenga et al.(2013)</label><mixed-citation>
Reijenga, J., Van Hoof, A., Van Loon, A., and Teunissen, B.: Development of
methods for the determination of pKa values, Anal. Chem. Insights, 8, 53–71,
2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Robert-Baldo et al.(1985)</label><mixed-citation>
Robert-Baldo, G. L., Morris, M. J., and Byrne, R. H.: Spectrophotometric
determination of seawater pH using phenol red, Anal. Chem., 57, 2564–2567,
1985.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Safavi and Bagheri(2003)</label><mixed-citation>
Safavi, A. and Bagheri, M.: Novel optical pH sensor for high and low pH
values, Sensor. Actuat. B-Chem., 90, 143–150, 2003.

</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Salk et al.(1954)</label><mixed-citation>
Salk, J. E., Youngner, J., and Ward, E. N.: Use of color change of phenol red
as the indicator in titrating poliomyelitis virus or its antibody in a
tissue-culture system, Am. J. Hyg., 60, 214–30, 1954.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Song et al.(1997)</label><mixed-citation>
Song, A., Parus, S., and Kopelman, R.: High-performance fiber-optic pH
microsensors for practical physiological measurements using a dual-emission
sensitive dye, Anal. Chem., 69, 863–867, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Stahl et al.(2006)</label><mixed-citation>
Stahl, H., Glud, A., Schröder, C. R., Klimant, I., Tengberg, A., and
Glud, R. N.: Time-resolved pH imaging in marine sediments with a luminescent
planar optode, Limnol. Oceanogr.-Meth., 4, 336–345, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Tucker et al.(1989)</label><mixed-citation>
Tucker, S., Robinson, R., Keane, C., Boff, M., Zenko, M., Batish, S., and
Street, K. W.: Colorimetric determination of pH, J. Chem. Educ., 66, 769 pp.,
1989.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Weigl et al.(1994)</label><mixed-citation>
Weigl, B. H., Holobar, A., Trettnak, W., Klimant, I., Kraus, H., O'Leary, P.,
and Wolfbeis, O. S.: Optical triple sensor for measuring pH, oxygen and
carbon dioxide, J. Biotechnol., 32, 127–138, 1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Yacynych et al.(1990)</label><mixed-citation>
Yacynych, A. M., Twork, J. V., and McGregor, W. C.: Sensors in bioprocess
control, Dekker New York, 1990.
</mixed-citation></ref-html>--></article>
