Continuous in-line monitoring of electrolyte concentrations in extracorporeal circuits for individualization of dialysis treatment

Marc Berger, Michael Faulstich, Thorsten Perl, and Stefan Zimmermann

Related authors

In-line monitoring of electrolytes and urea during continuous renal replacement therapy
Marc Berger, Merle Sehlmeyer, Flora Sellering, Hannes Röhrich, Thorsten Perl, Hussam Mansour, Daniel Baasner, and Stefan Zimmermann
J. Sens. Sens. Syst., 9, 251–262, https://doi.org/10.5194/jsss-9-251-2020,https://doi.org/10.5194/jsss-9-251-2020, 2020
Short summary

Related subject area

Applications: Medical
In-line monitoring of electrolytes and urea during continuous renal replacement therapy
Marc Berger, Merle Sehlmeyer, Flora Sellering, Hannes Röhrich, Thorsten Perl, Hussam Mansour, Daniel Baasner, and Stefan Zimmermann
J. Sens. Sens. Syst., 9, 251–262, https://doi.org/10.5194/jsss-9-251-2020,https://doi.org/10.5194/jsss-9-251-2020, 2020
Short summary
A novel non-invasive, non-conductive method for measuring respiration
Jan Ringkamp, Philipp Radler, Philipp Lebhardt, and Jens Langejürgen
J. Sens. Sens. Syst., 9, 27–32, https://doi.org/10.5194/jsss-9-27-2020,https://doi.org/10.5194/jsss-9-27-2020, 2020
Short summary
Task-specific uncertainty estimation for medical CT measurements
Judith Bredemann and Robert H. Schmitt
J. Sens. Sens. Syst., 7, 627–635, https://doi.org/10.5194/jsss-7-627-2018,https://doi.org/10.5194/jsss-7-627-2018, 2018
Short summary
The influence of intraocular pressure on the damping of a coupled speaker–air–eye system
Jan Osmers, Ágnes Patzkó, Oskar Hoppe, Michael Sorg, Axel von Freyberg, and Andreas Fischer
J. Sens. Sens. Syst., 7, 123–130, https://doi.org/10.5194/jsss-7-123-2018,https://doi.org/10.5194/jsss-7-123-2018, 2018
Short summary
Hyperspectral imaging for monitoring oxygen saturation levels during normothermic kidney perfusion
Florian Tetschke, Wenke Markgraf, Marian Gransow, Susanne Koch, Christine Thiele, Axel Kulcke, and Hagen Malberg
J. Sens. Sens. Syst., 5, 313–318, https://doi.org/10.5194/jsss-5-313-2016,https://doi.org/10.5194/jsss-5-313-2016, 2016
Short summary

Cited articles

Bagshaw, S. M., George, C., and Bellomo, R.: Early acute kidney injury and sepsis: A multicentre evaluation, Crit. Care, 12, R47, https://doi.org/10.1186/cc6863, 2008. 
Baue, A. E., Faist, E., and Fry, D. E.: Multiple Organ Failure: Pathophysiology, Prevention, and Therapy, N, Springer New York, New York, 1, online resource 722, 2000. 
Bellomo, R., Kellum, J. A., and Ronco, C.: Acute kidney injury, The Lancet, 380, 756–766, https://doi.org/10.1016/S0140-6736(11)61454-2, 2012. 
Buemi, M., Aloisi, E., Coppolino, G., Loddo, S., Crascì, E., Aloisi, C., Barillà, A., Cosentini, V., Nostro, L., Caccamo, C., Floccari, F., Romeo, A., Frisina, N., and Teti, D.: The effect of two different protocols of potassium haemodiafiltration on QT dispersion, Nephrol. Dial. Transpl., 20, 1148–1154, https://doi.org/10.1093/ndt/gfh770, 2005. 
Bundesärztekammer: Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen, Deutsches Ärzteblatt, 111, A 1583–A 1618, 2014. 
Download
Short summary
A dialysis treatment with an individual dialysis fluid composition can prevent certain complications during treatment. For this purpose, it is necessary to know the exact electrolyte concentrations in the blood. In this work, we present a concept for continuous in-line monitoring of electrolyte concentrations using ion-selective electrodes separated from the blood flow by a dialysis membrane. First investigations of this concept show no hemolysis and a relative error of less than 0.5 %.