Articles | Volume 3, issue 1
https://doi.org/10.5194/jsss-3-77-2014
https://doi.org/10.5194/jsss-3-77-2014
Regular research article
 | 
10 Apr 2014
Regular research article |  | 10 Apr 2014

Capacitive strain gauges on flexible polymer substrates for wireless, intelligent systems

R. Zeiser, T. Fellner, and J. Wilde

Related authors

Assembly and interconnection technology for high-temperature bulk acoustic wave resonators
Fabian Kohler, Monika Farina, Michal Schulz, Holger Fritze, and Jürgen Wilde
J. Sens. Sens. Syst., 11, 83–97, https://doi.org/10.5194/jsss-11-83-2022,https://doi.org/10.5194/jsss-11-83-2022, 2022
Short summary
High-temperature behavior of housed piezoelectric resonators based on CTGS
Michal Schulz, Rezvan Ghanavati, Fabian Kohler, Jürgen Wilde, and Holger Fritze
J. Sens. Sens. Syst., 10, 271–279, https://doi.org/10.5194/jsss-10-271-2021,https://doi.org/10.5194/jsss-10-271-2021, 2021
Short summary

Related subject area

Sensor principles and phenomena: Mechanical and inertial sensors
Telemetric angle and position sensing using millimeter-wave metamaterial and a frequency-modulated continuous-wave (FMCW) chip
Alexander Schossmann, Michael Töfferl, Christoph Schmidt, and Alexander Bergmann
J. Sens. Sens. Syst., 13, 31–39, https://doi.org/10.5194/jsss-13-31-2024,https://doi.org/10.5194/jsss-13-31-2024, 2024
Short summary
Measurement uncertainty analysis of a measurement flexure hinge in a torque standard machine
Kai Geva, Holger Kahmann, Christian Schlegel, and Rolf Kumme
J. Sens. Sens. Syst., 11, 201–209, https://doi.org/10.5194/jsss-11-201-2022,https://doi.org/10.5194/jsss-11-201-2022, 2022
Short summary
Creep adjustment of strain gauges based on granular NiCr-carbon thin films
Maximilian Mathis, Dennis Vollberg, Matthäus Langosch, Dirk Göttel, Angela Lellig, and Günter Schultes
J. Sens. Sens. Syst., 10, 53–61, https://doi.org/10.5194/jsss-10-53-2021,https://doi.org/10.5194/jsss-10-53-2021, 2021
Short summary
A tactile sensor based on magneto-sensitive elastomer to determine the position of an indentation
Simon Gast and Klaus Zimmermann
J. Sens. Sens. Syst., 9, 319–326, https://doi.org/10.5194/jsss-9-319-2020,https://doi.org/10.5194/jsss-9-319-2020, 2020
Short summary
Novel method to reduce the transverse sensitivity of granular thin film strain gauges by modification of strain transfer
Maximilian Mathis, Dennis Vollberg, Matthäus Langosch, Dirk Göttel, Angela Lellig, and Günter Schultes
J. Sens. Sens. Syst., 9, 219–226, https://doi.org/10.5194/jsss-9-219-2020,https://doi.org/10.5194/jsss-9-219-2020, 2020
Short summary

Cited articles

Aebersold, J., Walsh, K., Crain, M., Voor, M., Martin, M., Hnat, W., Lin, J., Jackson, D., and Naber, J.: Design, modeling, fabrication and testing of a MEMS capacitive bending strain sensor, J. Phys. Conf. Ser., 34, 124–129, 2006.
Arshak, K. I., McDonagh, D., Durcan, and M. A.: Development of new capacitive strain sensors based on thick film polymer and cermet technologies, Sensor. Actuator., 79, 102–114, 2000.
DuPont: Kapton polyimide film – summary of properties, DuPont, 24, p. 5, 2008.
Igreja, R. and Dias, C. J.: Analytical evaluation of the interdigital electrodes capacitance for a multi-layered structure, Sensor. Actuator. A-Phys., 112, 291–301, 2004.
Joerger, T.: Wireless sensor-systems with energy-optimized strain measurement, B.Sc. thesis, Dept. Micro-systems Eng., Univ. of Freiburg, Freiburg, Germany, 2010.
Download

The requested paper has a corresponding corrigendum published. Please read the corrigendum first before downloading the article.