Articles | Volume 7, issue 2
https://doi.org/10.5194/jsss-7-587-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.
the Creative Commons Attribution 4.0 License.
https://doi.org/10.5194/jsss-7-587-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.
the Creative Commons Attribution 4.0 License.
Static behavior of weighing cells
Maximilian Darnieder
CORRESPONDING AUTHOR
Precision Engineering Group, Institute for Design and Precision Engineering, Department of Mechanical Engineering,
Technische Universität Ilmenau, Germany
Markus Pabst
Process Measurement Group, Institute of Process Measurement and Sensor Technology, Department of Mechanical Engineering,
Technische Universität Ilmenau, Germany
Ronny Wenig
Process Measurement Group, Institute of Process Measurement and Sensor Technology, Department of Mechanical Engineering,
Technische Universität Ilmenau, Germany
Lena Zentner
Compliant Systems Group, Department of Mechanical Engineering, Technische Universität Ilmenau, Germany
René Theska
Precision Engineering Group, Institute for Design and Precision Engineering, Department of Mechanical Engineering,
Technische Universität Ilmenau, Germany
Thomas Fröhlich
Process Measurement Group, Institute of Process Measurement and Sensor Technology, Department of Mechanical Engineering,
Technische Universität Ilmenau, Germany
Related authors
Markus Pabst, Maximilian Darnieder, René Theska, and Thomas Fröhlich
J. Sens. Sens. Syst., 11, 109–116, https://doi.org/10.5194/jsss-11-109-2022, https://doi.org/10.5194/jsss-11-109-2022, 2022
Short summary
Short summary
An adjustment concept for high-precision weighing cells has been developed and experimentally investigated. It allows for minimization of uncertainty contributions due to tilt while maximizing sensitivity to mass. By applying the adjustment capabilities to new weighing cells, the devices can simultaneously become more accurate, more adaptable and more robust.
Markus Pabst, Maximilian Darnieder, René Theska, and Thomas Fröhlich
J. Sens. Sens. Syst., 11, 109–116, https://doi.org/10.5194/jsss-11-109-2022, https://doi.org/10.5194/jsss-11-109-2022, 2022
Short summary
Short summary
An adjustment concept for high-precision weighing cells has been developed and experimentally investigated. It allows for minimization of uncertainty contributions due to tilt while maximizing sensitivity to mass. By applying the adjustment capabilities to new weighing cells, the devices can simultaneously become more accurate, more adaptable and more robust.
Stefan Henning, Sebastian Linß, and Lena Zentner
Mech. Sci., 9, 389–404, https://doi.org/10.5194/ms-9-389-2018, https://doi.org/10.5194/ms-9-389-2018, 2018
Short summary
Short summary
A novel computational design tool to calculate the elasto-kinematic flexure hinge properties is presented. Four hinge contours are implemented. It is shown, that FEM results correlate well with the analytical design tool results. For a given deflection angle of 10° and a corner-filleted contour, the deviations of the bending stiffness are between 0.1 % and 9.4 %. The design tool can be beneficial for the accelerated and systematic synthesis of compliant mechanisms with optimized flexure hinges.
Silke Augustin, Thomas Fröhlich, Marc Schalles, and Stefan Krummeck
J. Sens. Sens. Syst., 7, 331–337, https://doi.org/10.5194/jsss-7-331-2018, https://doi.org/10.5194/jsss-7-331-2018, 2018
Short summary
Short summary
In the data sheets of the thermometer manufacturers, different specifications can be found to describe the dynamic properties of contact thermometers. The present paper describes the results of a bilateral comparison made for the first time for determining dynamic parameters for two thermocouples in the laboratories of the JUMO GmbH & Co. KG Fulda company and at the Institute of Process Measurement and Sensor Technology of the TU Ilmenau with similar facilities, but different results.
Sebastian Linß, Philipp Schorr, and Lena Zentner
Mech. Sci., 8, 29–49, https://doi.org/10.5194/ms-8-29-2017, https://doi.org/10.5194/ms-8-29-2017, 2017
Short summary
Short summary
Notch flexure hinges are often used as revolute joints in high-precise compliant mechanisms. Therefore, this paper presents design equations for the calculation of the rotational stiffness, maximal angular elastic deflection and rotational precision of various notch flexure hinges in dependence of the hinge parameters and the load. Four flexure hinge contours are investigated, the semi-circular, the corner-filleted, the elliptical, and the recently introduced bi-quadratic polynomial contour.
Related subject area
Sensor principles and phenomena: Mechanical and inertial sensors
Telemetric angle and position sensing using millimeter-wave metamaterial and a frequency-modulated continuous-wave (FMCW) chip
Measurement uncertainty analysis of a measurement flexure hinge in a torque standard machine
Creep adjustment of strain gauges based on granular NiCr-carbon thin films
A tactile sensor based on magneto-sensitive elastomer to determine the position of an indentation
Novel method to reduce the transverse sensitivity of granular thin film strain gauges by modification of strain transfer
Multi-parameter sensing using thickness shear mode (TSM) resonators – a feasibility analysis
Cylinder pressure sensors for smart combustion control
Flexible piezoresistive sensor matrix based on a carbon nanotube PDMS composite for dynamic pressure distribution measurement
Measuring the wheel-rail forces of a roller coaster
Frequency response and self-noise of the MET hydrophone
3-D-printed smart screw: functionalization during additive fabrication
Employing electro-mechanical analogies for co-resonantly coupled cantilever sensors
Offset stable piezoresistive high-temperature pressure sensors based on silicon
Silicon micro-levers and a multilayer graphene membrane studied via laser photoacoustic detection
Thin film sensors for measuring small forces
Capacitive strain gauges on flexible polymer substrates for wireless, intelligent systems
Ultrasound-based density determination via buffer rod techniques: a review
Driving modes and material stability of a double membrane rheometer and density sensor
Compensation method in sensor technology: a system-based description
Alexander Schossmann, Michael Töfferl, Christoph Schmidt, and Alexander Bergmann
J. Sens. Sens. Syst., 13, 31–39, https://doi.org/10.5194/jsss-13-31-2024, https://doi.org/10.5194/jsss-13-31-2024, 2024
Short summary
Short summary
We present a concept for angle and position measurement based on metamaterials. The distance between the sensor and the rotating or moving metamaterial target is not limited to a precise value. We use state-of-the-art millimeter wave radar chip technology for read-out, initially intended for applications such as gesture recognition or contactless switches. We implement a demonstrator test setup and show the proof of principle.
Kai Geva, Holger Kahmann, Christian Schlegel, and Rolf Kumme
J. Sens. Sens. Syst., 11, 201–209, https://doi.org/10.5194/jsss-11-201-2022, https://doi.org/10.5194/jsss-11-201-2022, 2022
Short summary
Short summary
The measurement principle shows how to measure calibration torque moment shunts in a 5 MN m torque standard machine using an interferometer and hinge flexure stiffness. The analysis of the measurement uncertainty influences shows that the measurement uncertainty of transversal force measurement ranges from 0.61 % to 3.04 % and stays constant at 1.7 % for torque measurement. A FE validation was performed. The measurement uncertainty of the calibration torque moment sank from 0.106 % to 0.100 %.
Maximilian Mathis, Dennis Vollberg, Matthäus Langosch, Dirk Göttel, Angela Lellig, and Günter Schultes
J. Sens. Sens. Syst., 10, 53–61, https://doi.org/10.5194/jsss-10-53-2021, https://doi.org/10.5194/jsss-10-53-2021, 2021
Short summary
Short summary
NiCr-carbon thin-film strain gauges offer the outstanding characteristic of a very high strain sensitivity. This can be very advantageous for many high-precision mechanical sensors like load cells. A downside of sensors based on these NiCr-carbon strain gauges is a rather large creep error, meaning reversible signal deviations at a constant load. We present two applicable methods for adjustment of the creep error: a modification of the film composition and a modification of the strain transfer.
Simon Gast and Klaus Zimmermann
J. Sens. Sens. Syst., 9, 319–326, https://doi.org/10.5194/jsss-9-319-2020, https://doi.org/10.5194/jsss-9-319-2020, 2020
Short summary
Short summary
In this paper, we present a tactile sensor based on the interaction of coils with a magnetic elastomer. The first experimental approach is sampling the sensor with indentations of constant depth at different positions. A mathematical model is used to reproduce the data. Afterwards, this model is applied to random indentations at the same depth. As a result, we provide conceptual proof for position determination in one direction as a basis for a refined sensor design and further model approaches.
Maximilian Mathis, Dennis Vollberg, Matthäus Langosch, Dirk Göttel, Angela Lellig, and Günter Schultes
J. Sens. Sens. Syst., 9, 219–226, https://doi.org/10.5194/jsss-9-219-2020, https://doi.org/10.5194/jsss-9-219-2020, 2020
Short summary
Short summary
This paper introduces a new method to drastically reduce the anisotropic strain sensitivity of granular thin film strain gauges. As a result, these improved strain gauges produce a much higher sensor signal when used for force transducers with biaxial strain fields. This gauge type is also more advantageous for uniaxial stress measurements. The method is based on the creation of a certain topographic structure of the strain gauges; in our case, this was realized by a picosecond laser system.
Manfred Weihnacht
J. Sens. Sens. Syst., 8, 133–147, https://doi.org/10.5194/jsss-8-133-2019, https://doi.org/10.5194/jsss-8-133-2019, 2019
Short summary
Short summary
Multi-parameter sensing is examined for thickness shear mode resonators that are in mechanical contact with thin films and half-spaces on both sides. A formula is derived that delivers insight into a set of material and geometry parameters accessible by measurement. Further analysis addresses the problem of accuracy of extracted parameters at a given experimental uncertainty. The demonstrated procedure is suitable for developing experimental strategy for highly efficient multi-parameter sensing.
Dennis Vollberg, Dennis Wachter, Thomas Kuberczyk, and Günter Schultes
J. Sens. Sens. Syst., 8, 75–85, https://doi.org/10.5194/jsss-8-75-2019, https://doi.org/10.5194/jsss-8-75-2019, 2019
Short summary
Short summary
The basis of our work presented in this paper stems from the research on new materials, especially temperature-stable thin films that transform strain into a resistance change very effectively, allowing higher sensitivity and higher operating temperatures. Different sensor concepts for time-resolved cylinder pressure monitoring of combustion engines are realized and evaluated. Reliable sensors with a minimum of internal components are provided.
Rajarajan Ramalingame, Zheng Hu, Carina Gerlach, Dhivakar Rajendran, Tatiana Zubkova, Reinhard Baumann, and Olfa Kanoun
J. Sens. Sens. Syst., 8, 1–7, https://doi.org/10.5194/jsss-8-1-2019, https://doi.org/10.5194/jsss-8-1-2019, 2019
Short summary
Short summary
An advanced-material-based thin, flexible sensor mat has been synthesized to record and visualize both the position and pressure of applied load. Such a pressure measurement system bears great potential in human health monitoring applications like long-term patient monitoring mattresses or insoles for gait monitoring.
Andreas Simonis and Christian Schindler
J. Sens. Sens. Syst., 7, 469–479, https://doi.org/10.5194/jsss-7-469-2018, https://doi.org/10.5194/jsss-7-469-2018, 2018
Dmitry L. Zaitsev, Svetlana Y. Avdyukhina, Maksim A. Ryzhkov, Iliya Evseev, Egor V. Egorov, and Vadim M. Agafonov
J. Sens. Sens. Syst., 7, 443–452, https://doi.org/10.5194/jsss-7-443-2018, https://doi.org/10.5194/jsss-7-443-2018, 2018
Short summary
Short summary
An electrochemical hydrophone based on the principles of molecular electronic transfer (MET) is described. The paper presents theoretical and experimental results for the sensitivity and the level of self-noise determination for METH in the frequency range of 0.02–200 Hz, which determines the fields of acceptance of the devices being developed. An experimental model has been developed by using a force-balancing feedback. Different methods and techniques for its calibration have been developed.
Daniel Gräbner, Simon Dödtmann, Gerrit Dumstorff, and Frieder Lucklum
J. Sens. Sens. Syst., 7, 143–151, https://doi.org/10.5194/jsss-7-143-2018, https://doi.org/10.5194/jsss-7-143-2018, 2018
Short summary
Short summary
We combine two modern trends in component fabrication, namely, the integration of sensors into machine parts and the 3-D-printing technology, which is rapidly emerging in the fabrication of standardized and customized components and prototypes. We present a 3-D-printed ‘smart’ screw with an integrated strain gauge. The signal of the sensor can be used to monitor the fastening process of the screw as well as the reduction in strength of the screw joint over time.
Julia Körner, Christopher F. Reiche, Bernd Büchner, Thomas Mühl, and Gerald Gerlach
J. Sens. Sens. Syst., 5, 245–259, https://doi.org/10.5194/jsss-5-245-2016, https://doi.org/10.5194/jsss-5-245-2016, 2016
Short summary
Short summary
The presented work gives insight into the behaviour of co-resonantly coupled oscillating cantilever beams by means of electro-mechanical analogies. An electric circuit model is analysed with various stages of complexity, and conclusions are drawn regarding the applicability of the co-resonant concept for sensors. Furthermore, this is validated by a comparison between the theoretical predictions and experimental data.
Robert Täschner, Erik Hiller, and Michael Blech
J. Sens. Sens. Syst., 5, 197–203, https://doi.org/10.5194/jsss-5-197-2016, https://doi.org/10.5194/jsss-5-197-2016, 2016
Short summary
Short summary
The exploitation of new application fields and the drive to size reduction even in highly stable pressure sensing systems makes the extension of the operating temperature range of the microelectromechanical sensors (MEMS) essential. For this reason, a silicon-based pressure sensor with an application temperature ranging up to 300 °C and the associated manufacturing technology was developed. The evolved sensor has an excellent stability and is uncomplicated to mount due to its stress insensitivity.
Z. Zelinger, P. Janda, J. Suchánek, M. Dostál, P. Kubát, V. Nevrlý, P. Bitala, and S. Civiš
J. Sens. Sens. Syst., 4, 103–109, https://doi.org/10.5194/jsss-4-103-2015, https://doi.org/10.5194/jsss-4-103-2015, 2015
Short summary
Short summary
We tested two types of home-made sensing elements – four coupled silicon micro-levers and a multilayer graphene membrane – which have the potential to further enhance the sensitivity of laser photoacoustic spectroscopy. Graphene sheets possess outstanding electromechanical properties and demonstrate impressive sensitivity as mass detectors. Their mechanical properties make them suitable for use as micro-/nano-levers or membranes, which could function as extremely sensitive pressure sensors.
F. Schmaljohann, D. Hagedorn, and F. Löffler
J. Sens. Sens. Syst., 4, 91–95, https://doi.org/10.5194/jsss-4-91-2015, https://doi.org/10.5194/jsss-4-91-2015, 2015
R. Zeiser, T. Fellner, and J. Wilde
J. Sens. Sens. Syst., 3, 77–86, https://doi.org/10.5194/jsss-3-77-2014, https://doi.org/10.5194/jsss-3-77-2014, 2014
S. Hoche, M. A. Hussein, and T. Becker
J. Sens. Sens. Syst., 2, 103–125, https://doi.org/10.5194/jsss-2-103-2013, https://doi.org/10.5194/jsss-2-103-2013, 2013
B. Weiss, M. Heinisch, E. K. Reichel, and B. Jakoby
J. Sens. Sens. Syst., 2, 19–26, https://doi.org/10.5194/jsss-2-19-2013, https://doi.org/10.5194/jsss-2-19-2013, 2013
V. Schulz, G. Gerlach, and K. Röbenack
J. Sens. Sens. Syst., 1, 5–27, https://doi.org/10.5194/jsss-1-5-2012, https://doi.org/10.5194/jsss-1-5-2012, 2012
Cited articles
Bacher, J.-P., Joseph, C., and Clavel, R.: Flexures for high precision
robotics, Ind. Robot, 29, 349–353,
https://doi.org/10.1108/01439910210432911, 2002. a
Baumann, H., Eichenberger, A., Cosandier, F., Jeckelmann, B., Clavel, R.,
Reber, D., and Tommasini, D.: Design of the new METAS watt balance experiment
Mark II, Metrologia, 50, 235–242, https://doi.org/10.1088/0026-1394/50/3/235, 2013. a
Baumgartl, H., Hilbrunner, F., Fröhlich, T., and Jäger, G.: Parametric
mechatronic model of a load cell with electromagnetic force compensation,
IMEKO TC3 & TC5 & TC22 International Conference: [IMEKO 2010 held
in Pattaya, Thailand from 21 to 25 November 2010; Metrology in modern
context], 29–32, 2010. a
Darnieder, M., Theska, R., Fröhlich, T., Pabst, M., Wenig, R., and
Hilbrunner, F.: Design of high-precision weighing cells based on static
analysis, Engineering for a changing world: 59th IWK, Ilmenau Scientific
Colloquium, Technische Universität Ilmenau, 11–15 September 2017:
proceedings, 2017. a
Darnieder, M., Fröhlich, T., and Theska, R.: Tilt sensitivity modeling of a
monolithic weighing cell structure, in: Interdisciplinary Applications of
Kinematics, edited by: Kecskeméthy, A. and Geu Flores, F., Springer
International Publishing, 2018. a
Eastman, F. S.: The Design of Flexure Pivots, J. Aeronaut.
Sci., 5, 16–21, https://doi.org/10.2514/8.499, 1937. a
Gläser, M. and Borys, M.: Precision mass measurements, Rep. Prog.
Phys., 72, 126101, https://doi.org/10.1088/0034-4885/72/12/126101, 2009. a, b, c
Gräser, P., Linß, S., Zentner, L., and Theska, R.: On the influence of
the flexure hinge orientation in planar compliant mechanisms for
ultra-precision applications, Engineering for a changing world: 59th IWK,
Ilmenau Scientific Colloquium, Technische Universität Ilmenau, 11–15
September 2017: proceedings, 2017. a
Henein, S., Aymon, C., Bottinelli, S., and Clavel, R.: Fatigue failure of thin
wire-electrodischarge-machined flexure hinges, in: Proc. SPIE 3834,
Microrobotics and Microassembly, edited by: Nelson, B. J. and Breguet, J.-M.,
SPIE Proceedings, 110–121, SPIE, https://doi.org/10.1117/12.357815, 1999. a
Hilbrunner, F., Baumgartl, H., Fröhlich, T., and Jäger, G.: Comparison
of different load changers for EMFC-balances, IMEKO TC3 & TC5 & TC22
International Conference: [IMEKO 2010 held in Pattaya, Thailand from
21st to 25th November 2010; Metrology in modern context], 65–68, 2010. a
Hilbrunner, F., Baumgartl, H., Petzold, R., Fröhlich, T., and Jäger,
G.: Investigation on the impedance-frequency-response for a dynamic behaviour
description of elecromagnetic force compensated load-cells, Proceedings of XX
IMEKO World Congress: 9–14 September 2012, Bexco, Busan,
Republic of Korea, 2012. a
Hilbrunner, F., Weis, H., and Fröhlich, T.: Parameterization and
optimisation of EMC balances based on the frequency response of the
impedance, Measurement, 51, 349–355,
https://doi.org/10.1016/j.measurement.2014.01.032, 2014. a
Hilbrunner, F., Rahneberg, I., and Fröhlich, T.: Watt balance with lever
transmission based on commercial EMFC load cell, Tech. Mess.,
85, 658–679, https://doi.org/10.1515/teme-2017-0065, 2017. a
Kochsiek, M. and Gläser, M.: Comprehensive mass metrology, Wiley-VCH,
Weinheim and New York, https://doi.org/10.1002/3527602992, 2000. a
Kühnel, M., Rivero, M., Diethold, C., Hilbrunner, F., and Fröhlich, T.:
Dual axis tiltmeter with nanorad resolution based on commercial force
compensation weigh cells, Shaping the future by engineering: 58th IWK,
Ilmenau Scientific Colloquium, Technische Universität Ilmenau, 8–12
September 2014; proceedings, 2014. a, b
Kühnel, M., Fern, F., and Fröhlich, T.: Novel monolithic pendulum
tiltmeter with Nanorad resolution, Tech. Mess., 85, 244–251,
https://doi.org/10.1515/teme-2017-0097, 2018. a
Linß, S., Schorr, P., and Zentner, L.: General design equations for the rotational stiffness,
maximal angular deflection and rotational precision of various notch flexure hinges, Mech. Sci., 8, 29–49, https://doi.org/10.5194/ms-8-29-2017, 2017. a
Marangoni, R. R., Rahneberg, I., Hilbrunner, F., Theska, R., and Fröhlich,
T.: Analysis of weighing cells based on the principle of electromagnetic
force compensation, Meas. Sci. Technol., 28, 75101,
https://doi.org/10.1088/1361-6501/aa6bcd, 2017. a, b
Quinn, T. J.: The beam balance as an instrument for very precise weighing,
Meas. Sci. Technol., 3, 141–159, https://doi.org/10.1088/0957-0233/3/2/001,
1992. a, b
Quinn, T. J., Speake, C. C., and Davis, R. S.: A 1 kg Mass Comparator Using
Flexure-Strip Suspensions: Preliminary Results, Metrologia, 23, 87, https://doi.org/10.1088/0026-1394/23/2/002,
1986. a
Richard, P., Fang, H., and Davis, R.: Foundation for the redefinition of the
kilogram, Metrologia, 53, A6–A11, https://doi.org/10.1088/0026-1394/53/5/A6, 2016. a
Rothleitner, C., Schleichert, J., Rogge, N., Günther, L., Vasilyan, S.,
Hilbrunner, F., Knopf, D., Fröhlich, T., and Härtig, F.: The
Planck-Balance–using a fixed value of the Planck constant to calibrate
E1/E2-weights, Meas. Sci. Technol., 29, 074003,
https://doi.org/10.1088/1361-6501/aabc9e, 2018. a
Smith, S. T. and Chetwynd, D. G.: Foundations of ultraprecision mechanism
design, vol. v. 2 of Developments in nanotechnology, Gordon and
Breach Science Publishers, Yverdon, Switzerland, 1992. a
Stock, M., Barat, P., Davis, R. S., Picard, A., and Milton, M. J. T.:
Calibration campaign against the international prototype of the kilogram in
anticipation of the redefinition of the kilogram part I: Comparison of the
international prototype with its official copies, Metrologia, 52, 310–316,
https://doi.org/10.1088/0026-1394/52/2/310, 2015. a