Overview on conductometric solid-state gas dosimeters
I. Marr
Department of Functional Materials, University of Bayreuth, Bayreuth, Germany
A. Groß
Department of Functional Materials, University of Bayreuth, Bayreuth, Germany
R. Moos
Department of Functional Materials, University of Bayreuth, Bayreuth, Germany
Related authors
No articles found.
Thomas Wöhrl, Julia Herrmann, Jaroslaw Kita, Ralf Moos, and Gunter Hagen
J. Sens. Sens. Syst., 12, 205–214, https://doi.org/10.5194/jsss-12-205-2023, https://doi.org/10.5194/jsss-12-205-2023, 2023
Short summary
Short summary
Sensors for detecting various gases, such as nitrogen oxides, play a major role in times of climate change in protecting the environment from the possible toxic influences of such gases. Due to their usually complex design, gas sensors may react to changes in the operating temperature, which can occur due to different ambient influences. This article shows two methods for accurately measuring the temperature on the surface of a sensor under realistic conditions.
Robin Werner, Jaroslaw Kita, Michael Gollner, Florian Linseis, and Ralf Moos
J. Sens. Sens. Syst., 12, 69–84, https://doi.org/10.5194/jsss-12-69-2023, https://doi.org/10.5194/jsss-12-69-2023, 2023
Short summary
Short summary
A high-temperature gauge to simultaneously determine electrical conductivity, the Hall constant, and the Seebeck coefficient was developed. Screen-printed heating structures on a ceramic sample holder generate temperatures up to 800 °C. Heating structures were designed using FEM simulations. The temperature distribution was validated by thermal imaging. Measurements on constantan (reference material) and boron-doped silicon wafer confirm the functionality of the gauge up to 800 °C.
Johanna Distler, Thomas Wöhrl, Robin Werner, Michael Gerlach, Michael Gollner, Florian Linseis, Jaroslaw Kita, and Ralf Moos
J. Sens. Sens. Syst., 12, 9–19, https://doi.org/10.5194/jsss-12-9-2023, https://doi.org/10.5194/jsss-12-9-2023, 2023
Short summary
Short summary
Differential scanning calorimetry (DSC) is a widely used tool to analyze thermal material properties. This study focuses on the advancement of a miniaturized DSC chip as an alternative to conventional devices. The first development steps for the integration of a weighing system are shown, starting with model considerations and simulation-based optimization to initial measurements. Three different measurement methods are investigated and show promising results.
Robin Werner, Jaroslaw Kita, Michael Gollner, Florian Linseis, and Ralf Moos
J. Sens. Sens. Syst., 10, 71–81, https://doi.org/10.5194/jsss-10-71-2021, https://doi.org/10.5194/jsss-10-71-2021, 2021
Short summary
Short summary
A novel, low-cost measurement device for simultaneous high temperature measurements of the electrical conductivity and Hall coefficient has been developed. Simulations were used to design a suitable screen-printed planar platinum heating structure that generates temperatures of up to 600 °C. Simulations of the temperature distribution have been validated using thermal imaging. Measurements were compared with data from the literature to validate the functionality of the novel device.
Anastasiya Ruchets, Nils Donker, Jens Zosel, Daniela Schönauer-Kamin, Ralf Moos, Ulrich Guth, and Michael Mertig
J. Sens. Sens. Syst., 9, 355–362, https://doi.org/10.5194/jsss-9-355-2020, https://doi.org/10.5194/jsss-9-355-2020, 2020
Short summary
Short summary
A commercial solid electrolyte gas sensor of the type "Pt|YSZ|Pt, air" based on yttria-stabilized zirconia for colorimetric oxygen detection was operated in optimized dynamic electrochemical modes. Cyclic voltammetry and square-wave voltammetry were used for the detection of NO and O2 in N2 in the temperature range between 550 and 750 °C. Due to the differences of electrode kinetics of the single components it is possible to detect these redox active gases selectively and quasi-simultaneously.
Julia Herrmann, Gunter Hagen, Jaroslaw Kita, Frank Noack, Dirk Bleicker, and Ralf Moos
J. Sens. Sens. Syst., 9, 327–335, https://doi.org/10.5194/jsss-9-327-2020, https://doi.org/10.5194/jsss-9-327-2020, 2020
Short summary
Short summary
In this contribution, an inexpensive and robust impedimetric NOx sensor is presented. The impedance of a functional thick film depends selectively on the NOx concentration in the exhaust but shows a dependency on the oxygen concentration. Therefore, an additional temperature-independent resistive oxygen sensor structure was integrated on the same sensor platform. It serves not only to determine the oxygen concentration in the exhaust, but also to correct the oxygen dependency of the NOx sensor.
Nils Donker, Anastasiya Ruchets, Daniela Schönauer-Kamin, Jens Zosel, Ulrich Guth, and Ralf Moos
J. Sens. Sens. Syst., 9, 293–300, https://doi.org/10.5194/jsss-9-293-2020, https://doi.org/10.5194/jsss-9-293-2020, 2020
Short summary
Short summary
Symmetrical Pt | YSZ | Pt–NO gas sensors were produced with frit-containing and fritless Pt electrodes and fired between 950 and 1300 °C. The sensors were operated by pulsed polarization. With fritless pastes, the sensors responded significantly higher. The firing temperature affects the sensitivity only slightly. The low NO sensitivity of the frit-containing electrodes was attributed to a blocking effect at the triple-phase boundaries that inhibits the oxygen transport through the sensor.
Stefanie Walter, Andreas Bogner, Gunter Hagen, and Ralf Moos
J. Sens. Sens. Syst., 8, 49–56, https://doi.org/10.5194/jsss-8-49-2019, https://doi.org/10.5194/jsss-8-49-2019, 2019
Short summary
Short summary
A planar resonant radio-frequency gas sensor was equipped with an integrated heater. By simulative geometry optimization it now can be operated up to 700 °C. Sensitive materials with gas-dependent dielectric properties at higher temperatures can now be used. By coating the sensor with zeolite, ammonia could be detected. Depending on the working temperature, the sensor returns either a dosimeter signal (low temperatures) or a gas-concentration-dependent radio-frequency signal (high temperatures).
Murat Bektas, Thomas Stöcker, Angelika Mergner, Gunter Hagen, and Ralf Moos
J. Sens. Sens. Syst., 7, 289–297, https://doi.org/10.5194/jsss-7-289-2018, https://doi.org/10.5194/jsss-7-289-2018, 2018
Short summary
Short summary
We prepared BaFe(1-x)-0.01Al0.01TaxO3-δ (BFATx) thick films with x between 0.1 and 0.4 at room temperature using the aerosol deposition method and we measured Seebeck coefficients and conductivities between 600 and 800 °C at different oxygen concentrations. Deposited on a transducer that includes a heater, equipotential layers, and electrode structures, a dual thermoelectric–resistive oxygen sensor with almost temperature-independent characteristics of both measurands was realized using BFAT30.
Gunter Hagen, Antonia Harsch, and Ralf Moos
J. Sens. Sens. Syst., 7, 79–84, https://doi.org/10.5194/jsss-7-79-2018, https://doi.org/10.5194/jsss-7-79-2018, 2018
Short summary
Short summary
Monitoring hydrocarbon concentrations in automotive exhausts is affected by flow rate changes. The signal of thermoelectric gas sensors is a thermovoltage. Its origin is a temperature difference that depends on the flow rate. To avoid this noise effect, the sensor can be installed in a defined bypass position. As shown by simulation and experiments, the gas flow around the sensor is almost turbulence-free and the signal only depends on the hydrocarbon concentration and not on the flow rate.
Thomas Ritter, Sven Wiegärtner, Gunter Hagen, and Ralf Moos
J. Sens. Sens. Syst., 6, 395–405, https://doi.org/10.5194/jsss-6-395-2017, https://doi.org/10.5194/jsss-6-395-2017, 2017
Short summary
Short summary
A planar thermoelectric gas sensor is modeled. By coupling all influences (fluid flow, gas diffusion, heat transfer, chemical reactions, and electrical properties) a model was set up that mirrors the sensor behavior precisely, as the comparison with experimental data shows. The coupling of 3-D and 1-D geometry enables to calculate the temperature distribution, fluid flow, and the gas concentration distribution in the 3-D model, while the chemical reactions are very accurately calculated in 1-D.
Franz Schubert, Michael Gollner, Jaroslaw Kita, Florian Linseis, and Ralf Moos
J. Sens. Sens. Syst., 5, 381–388, https://doi.org/10.5194/jsss-5-381-2016, https://doi.org/10.5194/jsss-5-381-2016, 2016
Short summary
Short summary
An FEM model is used to improve the sensor design of a Tian–Calvet calorimeter. By modifying the basic part of the sensor (a sensor disc based on low temperature co-fired ceramics), the sensitivity was increased by a factor of 3. The model was validated and the sensors were calibrated. Indium and tin samples were measured. The melting temperatures show a deviation of 0.2 K while the enthalpy was measured with a precision better than 1 %. The values for tin deviate by less than 2 % from literature.
Franz Schubert, Michael Gollner, Jaroslaw Kita, Florian Linseis, and Ralf Moos
J. Sens. Sens. Syst., 5, 205–212, https://doi.org/10.5194/jsss-5-205-2016, https://doi.org/10.5194/jsss-5-205-2016, 2016
Short summary
Short summary
Initial steps to apply a new ceramic multi-layer sensor for a Tian–Calvet calorimeter are shown. The FEM-developed sensor consists of stacked ceramic discs and insulation rings. The functionality of the sensor disc was proven up to 600 °C and the entire stack was tested at room temperature. The resolution was 5 µW and the sensitivity was 8.5 µV mW−1. The new sensor shows similar specifications as commercial devices and presents a good starting point for future high temperature applications.
F. Schubert, S. Wollenhaupt, J. Kita, G. Hagen, and R. Moos
J. Sens. Sens. Syst., 5, 25–32, https://doi.org/10.5194/jsss-5-25-2016, https://doi.org/10.5194/jsss-5-25-2016, 2016
Short summary
Short summary
A manufacturing process for a planar binary lambda sensor is shown. By joining the heating and the sensing components via glass soldering with a joining temperature of 850 °C, a laboratory platform has been established that allows the manufacturing of two independent parts in HTCC technology with electrodes that are post-processed at lower temperatures, as is required for mixed-potential sensors. The concept has been proved by comparing the device with a commercial sensor.
S. Fischer, D. Schönauer-Kamin, R. Pohle, M. Fleischer, and R. Moos
J. Sens. Sens. Syst., 4, 321–329, https://doi.org/10.5194/jsss-4-321-2015, https://doi.org/10.5194/jsss-4-321-2015, 2015
Short summary
Short summary
Thimble-type lambda probes that are known for their robustness in harsh exhausts can also be used as an NOx sensor by applying the pulsed polarization technique. This study evaluates in detail the influence of temperature on the NO sensitivity, so that an optimum operating point can be derived. Stepwise NO concentration changes between 0 and 12.5 ppm in synthetic exhausts demonstrate the high potential of this concept.
M. Dietrich, D. Rauch, U. Simon, A. Porch, and R. Moos
J. Sens. Sens. Syst., 4, 263–269, https://doi.org/10.5194/jsss-4-263-2015, https://doi.org/10.5194/jsss-4-263-2015, 2015
Short summary
Short summary
The effect of stored ammonia on the complex dielectric permittivity of H-ZSM-5 zeolites with varying storage site density was observed between 200 and 300 °C under reaction conditions by microwave cavity perturbation. Polarization and dielectric losses were differently affected. The sensitivity of the polarization to stored ammonia is almost independent, the sensitivity of the dielectric losses strongly dependent on the storage site density. The results can be explained by proton hopping.
P. Fremerey, A. Jess, and R. Moos
J. Sens. Sens. Syst., 4, 143–149, https://doi.org/10.5194/jsss-4-143-2015, https://doi.org/10.5194/jsss-4-143-2015, 2015
Short summary
Short summary
A concept to measure in situ sulfidation of silica pellet catalysts loaded with nickel is evaluated. During sulfidation between 100 and 400°C nickel sulfides form. The electrical impedance of the pellets was recorded in situ. At first, the particles are highly insulating but during sulfidation their conductivity increases by decades. Since nickel sulfides are less conductive than nickel, the strong conductivity increase may be due to conducting percolation paths that form during sulfidation.
M. Bektas, D. Hanft, D. Schönauer-Kamin, T. Stöcker, G. Hagen, and R. Moos
J. Sens. Sens. Syst., 3, 223–229, https://doi.org/10.5194/jsss-3-223-2014, https://doi.org/10.5194/jsss-3-223-2014, 2014
P. Bartscherer and R. Moos
J. Sens. Sens. Syst., 2, 95–102, https://doi.org/10.5194/jsss-2-95-2013, https://doi.org/10.5194/jsss-2-95-2013, 2013
Related subject area
Sensor principles and phenomena: Chemical and biochemical sensors
Development of electrochemical sensors based on silver nanoparticles electrodeposited on gold screen-printed electrodes: application to nitrate trace analysis in water
Chemical hydrogel sensors based on the bimorph effect with short response time
Design of a dual electrochemical quartz crystal microbalance with dissipation monitoring
Surface plasmon assisted toxic chemical NO2 gas sensor by Au ∕ ZnO functional thin films
Studies on porosity in poly(N-isopropylacrylamide) hydrogels for fast-responsive piezoresistive microsensors
Ceramic multilayer technology as a platform for miniaturized sensor arrays for water analysis
Glass electrode half-cells for measuring unified pH in ethanol–water mixtures
Cyclic and square-wave voltammetry for selective simultaneous NO and O2 gas detection by means of solid electrolyte sensors
Multi-gas sensor to detect simultaneously nitrogen oxides and oxygen
Influence of Pt paste and the firing temperature of screen-printed electrodes on the NO detection by pulsed polarization
Siloxane treatment of metal oxide semiconductor gas sensors in temperature-cycled operation – sensitivity and selectivity
Determination of the mixing ratio of a flowing gas mixture with self-actuated microcantilevers
Enabling a new method of dynamic field-effect gas sensor operation through lithium-doped tungsten oxide
Optical and impedimetric study of genetically modified cells for diclofenac sensing
Novel radio-frequency-based gas sensor with integrated heater
Highly sensitive coulometric titration of oxygen for the characterization of solid materials at elevated temperatures
Trace determination of cadmium content in Malaysian herbs using graphene–ionic liquid-modified screen-printed carbon electrodes
Novel method for the detection of short trace gas pulses with metal oxide semiconductor gas sensors
A portable sensor system for bacterial concentration monitoring in metalworking fluids
Thin-film SnO2 and ZnO detectors of hydrogen peroxide vapors
Combined resistive and thermoelectric oxygen sensor with almost temperature-independent characteristics
Hydrogel-based piezoresistive sensor for the detection of ethanol
High-resolution ultrasonic spectroscopy
Design and evaluation of split-ring resonators for aptamer-based biosensors
Nanocomposite sensors of propylene glycol, dimethylformamide and formaldehyde vapors
Simulation of a thermoelectric gas sensor that determines hydrocarbon concentrations in exhausts and the light-off temperature of catalyst materials
Electron capture detector based on a non-radioactive electron source: operating parameters vs. analytical performance
Electrical impedance spectroscopy (EIS) for biological analysis and food characterization: a review
A DNA biosensor for molecular diagnosis of Aeromonas hydrophila using zinc sulfide nanospheres
H2S dosimeter with controllable percolation threshold based on semi-conducting copper oxide thin films
The concept of thin film bulk acoustic resonators as selective CO2 gas sensors
Biochemical piezoresistive sensors based on hydrogels for biotechnology and medical applications
Highly selective solid electrolyte sensor for the analysis of gaseous mixtures
Gas sensors based on plasma-electrochemically oxidized titanium foils
First steps to develop a sensor for a Tian–Calvet calorimeter with increased sensitivity
Selective detection of naphthalene with nanostructured WO3 gas sensors prepared by pulsed laser deposition
Flexible free-standing SU-8 microfluidic impedance spectroscopy sensor for 3-D molded interconnect devices application
Paradigm change in hydrogel sensor manufacturing: from recipe-driven to specification-driven process optimization
Platform to develop exhaust gas sensors manufactured by glass-solder-supported joining of sintered yttria-stabilized zirconia
Influence of operation temperature variations on NO measurements in low concentrations when applying the pulsed polarization technique to thimble-type lambda probes
Self-sufficient sensor for oxygen detection in packaging via radio-frequency identification
Influence of the substrate on the overall sensor impedance of planar H2 sensors involving TiO2–SnO2 interfaces
Defects and gas sensing properties of carbon nanotube-based devices
Development of a capacitive chemical sensor based on Co(II)-phthalocyanine acrylate-polymer/HfO2/SiO2/Si for detection of perchlorate
Room temperature carbon nanotube based sensor for carbon monoxide detection
Compensation for the influence of temperature and humidity on oxygen diffusion in a reactive polymer matrix
Devices based on series-connected Schottky junctions and β-Ga2O3/SiC heterojunctions characterized as hydrogen sensors
A simple method to recover the graphene-based chemi-resistor signal
Electrochemical analysis of water and suds by impedance spectroscopy and cyclic voltammetry
Gas identification based on bias induced hysteresis of a gas-sensitive SiC field effect transistor
Najib Ben Messaoud, Marília Barreiros dos Santos, Begoña Espiña, and Raquel Barbosa Queirós
J. Sens. Sens. Syst., 13, 135–145, https://doi.org/10.5194/jsss-13-135-2024, https://doi.org/10.5194/jsss-13-135-2024, 2024
Short summary
Short summary
High levels of nitrate can cause negative effects on aquatic plants, fishes and human health. A simple, reusable and sensitive electrochemical sensor based on silver nanoparticles with a modified gold screen-printed electrode has been developed for the detection of nitrate in water. The sensor exhibited good performances such as high sensitivity, reproducibility, repeatability and selectivity. The proposed approach was successfully used to determine nitrate in freshwater.
Stefan Schreiber, Nadja Steinke, and Gerald Gerlach
J. Sens. Sens. Syst., 12, 141–146, https://doi.org/10.5194/jsss-12-141-2023, https://doi.org/10.5194/jsss-12-141-2023, 2023
Short summary
Short summary
We have managed to reduce the measuring time of previously common hydrogel-based sensors from a few minutes to a few seconds. For this, the arrangement of the hydrogel in the sensor was changed so that the volume of the hydrogel could be reduced. The biggest challenge, apart from generating a very thin pattern, was to firmly bond the hydrogel to a silicon surface. This was to ensure that the resulting forces of the bimorph effect can be absorbed.
Rafael Ecker, Nikolaus Doppelhammer, Bernhard Jakoby, and Erwin Konrad Reichel
J. Sens. Sens. Syst., 11, 21–28, https://doi.org/10.5194/jsss-11-21-2022, https://doi.org/10.5194/jsss-11-21-2022, 2022
Short summary
Short summary
A setup for the characterization of liquids with the perspective of monitoring crystallization processes is presented. The novelty of this setup is the realization of viscosity and conductivity measurements using two quartz crystal microbalances. Additionally, there is the possibility to apply an electric field through the sample, enabling the manipulation of charged particles. The results show that the measured values are in reasonable agreement with values from the literature or standards.
Ravinder Gaur, Himanshu Mohan Padhy, and Manikandan Elayaperumal
J. Sens. Sens. Syst., 10, 163–169, https://doi.org/10.5194/jsss-10-163-2021, https://doi.org/10.5194/jsss-10-163-2021, 2021
Short summary
Short summary
We propose a surface plasmon resonance (SPR) sensor based on a ZnO / Au hybrid thin-film material structure and experimentally investigate its sensitivity improvement. The Kretschmann-based SPR sensor utilizes ZnO thin films and nanostructures for performance enhancement. The advancement in SPR technology relies on a low-cost, high-sensitivity, and high-selectivity sensor. Metal oxide (MO) has been incorporated into the SPR sensor to be used for detection of biological and chemical compounds.
Daniela Franke and Gerald Gerlach
J. Sens. Sens. Syst., 10, 93–100, https://doi.org/10.5194/jsss-10-93-2021, https://doi.org/10.5194/jsss-10-93-2021, 2021
Claudia Feller and Uwe Partsch
J. Sens. Sens. Syst., 10, 83–91, https://doi.org/10.5194/jsss-10-83-2021, https://doi.org/10.5194/jsss-10-83-2021, 2021
Short summary
Short summary
Ion-selective electrodes have been proven useful in water analysis. They are usually used as single-rod measuring chains in different designs, which are manufactured using precision mechanical manufacturing and assembling technologies. The paper describes a microsystem technology approach for the fabrication of miniaturized electrochemical sensors. Design, manufacture, and performance of the novel ceramic multilayer-based sensor array are presented in the paper using various examples.
Agnes Heering, Frank Bastkowski, and Steffen Seitz
J. Sens. Sens. Syst., 9, 383–389, https://doi.org/10.5194/jsss-9-383-2020, https://doi.org/10.5194/jsss-9-383-2020, 2020
Short summary
Short summary
The new concept of a unified pH scale can be used to compare acidities of different kinds of solvents and their mixtures. The aim of the work was to investigate the robustness of the measurement method with four commercially available glass electrodes for non-aqueous media in comparison with the rather specific type of cell used so far for this measurement. The measurement results in aqueous mixtures of ethanol show good agreement.
Anastasiya Ruchets, Nils Donker, Jens Zosel, Daniela Schönauer-Kamin, Ralf Moos, Ulrich Guth, and Michael Mertig
J. Sens. Sens. Syst., 9, 355–362, https://doi.org/10.5194/jsss-9-355-2020, https://doi.org/10.5194/jsss-9-355-2020, 2020
Short summary
Short summary
A commercial solid electrolyte gas sensor of the type "Pt|YSZ|Pt, air" based on yttria-stabilized zirconia for colorimetric oxygen detection was operated in optimized dynamic electrochemical modes. Cyclic voltammetry and square-wave voltammetry were used for the detection of NO and O2 in N2 in the temperature range between 550 and 750 °C. Due to the differences of electrode kinetics of the single components it is possible to detect these redox active gases selectively and quasi-simultaneously.
Julia Herrmann, Gunter Hagen, Jaroslaw Kita, Frank Noack, Dirk Bleicker, and Ralf Moos
J. Sens. Sens. Syst., 9, 327–335, https://doi.org/10.5194/jsss-9-327-2020, https://doi.org/10.5194/jsss-9-327-2020, 2020
Short summary
Short summary
In this contribution, an inexpensive and robust impedimetric NOx sensor is presented. The impedance of a functional thick film depends selectively on the NOx concentration in the exhaust but shows a dependency on the oxygen concentration. Therefore, an additional temperature-independent resistive oxygen sensor structure was integrated on the same sensor platform. It serves not only to determine the oxygen concentration in the exhaust, but also to correct the oxygen dependency of the NOx sensor.
Nils Donker, Anastasiya Ruchets, Daniela Schönauer-Kamin, Jens Zosel, Ulrich Guth, and Ralf Moos
J. Sens. Sens. Syst., 9, 293–300, https://doi.org/10.5194/jsss-9-293-2020, https://doi.org/10.5194/jsss-9-293-2020, 2020
Short summary
Short summary
Symmetrical Pt | YSZ | Pt–NO gas sensors were produced with frit-containing and fritless Pt electrodes and fired between 950 and 1300 °C. The sensors were operated by pulsed polarization. With fritless pastes, the sensors responded significantly higher. The firing temperature affects the sensitivity only slightly. The low NO sensitivity of the frit-containing electrodes was attributed to a blocking effect at the triple-phase boundaries that inhibits the oxygen transport through the sensor.
Caroline Schultealbert, Iklim Uzun, Tobias Baur, Tilman Sauerwald, and Andreas Schütze
J. Sens. Sens. Syst., 9, 283–292, https://doi.org/10.5194/jsss-9-283-2020, https://doi.org/10.5194/jsss-9-283-2020, 2020
Short summary
Short summary
We present a work on gas sensors that can for example be used for the assessment of indoor air quality. These sensors suffer from deterioration by siloxanes, so we investigated these effects by a distinct operation mode and exposition to this gas that allows us to interpret different reactions on the sensor surface. We found that all processes on the sensor surface are slowed down by this treatment and a self-compensation by the evaluation of oxygen adsorption processes is likely to be found.
Jaqueline Stauffenberg, Steve Durstewitz, Martin Hofmann, Tzvetan Ivanov, Mathias Holz, Waleed Ehrhardt, Wolf-Ulrich Riegel, Jens-Peter Zöllner, Eberhard Manske, and Ivo Rangelow
J. Sens. Sens. Syst., 9, 71–78, https://doi.org/10.5194/jsss-9-71-2020, https://doi.org/10.5194/jsss-9-71-2020, 2020
Short summary
Short summary
In this work, a self-actuated microcantilever is used as a flow sensor. Its resonance frequency, resonance amplitude and static deflection are measured. Most conventional flow sensors are often only calibrated for one type of gas and allow an analysis of gas mixtures only with increased effort. The work examines whether the volumetric flow and the mixing ratio of a binary gas mixture are possible simultaneously from these measured variables.
Marius Rodner, Manuel Bastuck, Andreas Schütze, Mike Andersson, Joni Huotari, Jarkko Puustinen, Jyrki Lappalainen, and Tilman Sauerwald
J. Sens. Sens. Syst., 8, 261–267, https://doi.org/10.5194/jsss-8-261-2019, https://doi.org/10.5194/jsss-8-261-2019, 2019
Short summary
Short summary
To fulfil today's requirements, gas sensors have to become more and more sensitive and selective. In this work, we present a novel method to significantly enhance the effect of gate bias on the response of a SiC field-effect transistor by placing a lithium-doped tungsten oxide film beneath the gate. This enhancement, compared to undoped samples, opens new perspectives for static and transient signal generation, e.g. gate bias-cycled operation, and, thus, increasing sensitivity and selectivity.
Margarita Guenther, Falko Altenkirch, Kai Ostermann, Gerhard Rödel, Ingo Tobehn-Steinhäuser, Steffen Herbst, Stefan Görlandt, and Gerald Gerlach
J. Sens. Sens. Syst., 8, 215–222, https://doi.org/10.5194/jsss-8-215-2019, https://doi.org/10.5194/jsss-8-215-2019, 2019
Short summary
Short summary
In this work, genetically modified cells of the yeast Saccharomyces cerevisiae BY4741 were confined in a four-chamber microfluidic cell, providing an optical monitoring of the cell behaviour and their supply with the nutrients. The measurements of the time-dependent fluorescence intensity were performed with different concentrations of the drug diclofenac, and the sensitivity of yeast cells to diclofenac was demonstrated. Cell viability was monitored by simultaneous impedance recording.
Stefanie Walter, Andreas Bogner, Gunter Hagen, and Ralf Moos
J. Sens. Sens. Syst., 8, 49–56, https://doi.org/10.5194/jsss-8-49-2019, https://doi.org/10.5194/jsss-8-49-2019, 2019
Short summary
Short summary
A planar resonant radio-frequency gas sensor was equipped with an integrated heater. By simulative geometry optimization it now can be operated up to 700 °C. Sensitive materials with gas-dependent dielectric properties at higher temperatures can now be used. By coating the sensor with zeolite, ammonia could be detected. Depending on the working temperature, the sensor returns either a dosimeter signal (low temperatures) or a gas-concentration-dependent radio-frequency signal (high temperatures).
Alexander Herms, Jingying Yao, Jens Zosel, Vladimir Vashook, Wolfram Oelßner, and Michael Mertig
J. Sens. Sens. Syst., 7, 621–625, https://doi.org/10.5194/jsss-7-621-2018, https://doi.org/10.5194/jsss-7-621-2018, 2018
Short summary
Short summary
For the understanding of new materials, especially oxides, oxygen exchange of such materials and its consequences for their properties are of high interest. For this purpose a new setup for oxygen solid electrolyte coulometry with electrochemical cells made of yttria-stabilized zirconia (YSZ) is presented. It could be shown that this setup enables the measurement of exchanged oxygen from the picomol up to the higher nanomol range with a precision which was not achieved so far.
Muhammad Syafiq Nordin, Yusairie Mohd, Noor Fitrah Abu Bakar, and Zainiharyati Mohd Zain
J. Sens. Sens. Syst., 7, 481–487, https://doi.org/10.5194/jsss-7-481-2018, https://doi.org/10.5194/jsss-7-481-2018, 2018
Short summary
Short summary
Cadmium is one of heavy metals that can cause serious health complications if humans are excessively exposed. This research was conducted to detect the amount of cadmium inside herbal plants using a new sensor modified with graphene and ionic liquid. The amount of cadmium inside herbs A, D, M and C were 0.0035, 0.0237, 0.0267 and 0.0251 milligrams/litre, respectively. The results showed that the herbs were safe to be consumed. The developed sensor was comparable to existing detection methods.
Tobias Baur, Caroline Schultealbert, Andreas Schütze, and Tilman Sauerwald
J. Sens. Sens. Syst., 7, 411–419, https://doi.org/10.5194/jsss-7-411-2018, https://doi.org/10.5194/jsss-7-411-2018, 2018
Short summary
Short summary
A novel method for the detection of short pulses of gas at very low concentrations is presented. Applying the method to a doped SnO2 detector, gas pulses down to a dosage of 1 ppb times seconds can be detected. The gas transport inside the detector is simulated using the finite element method (FEM) to optimize the gas transport and to keep response and recovery time as short as possible. With this approach, we have demonstrated a detection limit for ethanol below 47 fg.
Marco Grossi, Carola Parolin, Beatrice Vitali, and Bruno Riccò
J. Sens. Sens. Syst., 7, 349–357, https://doi.org/10.5194/jsss-7-349-2018, https://doi.org/10.5194/jsss-7-349-2018, 2018
Short summary
Short summary
The paper presents a portable sensor system that measures the bacterial concentration in metalworking fluids (MWFs) exploiting impedance microbiology. Good agreement has been found between the system response and that of the reference plate count technique (PCT). The proposed system allows automated bacterial concentration measurements with shorter response times than the PCT (4 to 24 h vs. 24 to 72 h) and is suitable for in-the-field MWF monitoring.
Vladimir Aroutiounian, Valeri Arakelyan, Mikayel Aleksanyan, Gohar Shahnazaryan, Petr Kacer, Pavel Picha, Jiri Kovarik, Jakub Pekarek, and Berndt Joost
J. Sens. Sens. Syst., 7, 281–288, https://doi.org/10.5194/jsss-7-281-2018, https://doi.org/10.5194/jsss-7-281-2018, 2018
Short summary
Short summary
Some results of the solid-state hydrogen peroxide vapor sensors made from semiconductor doped metal oxide nanostructured films have been presented during the international conference in Nuremberg. In this paper the extended version of our investigations of the detectors of hydrogen peroxide vapors are presented. The prepared sensors exhibit a response to very low concentration of hydrogen peroxide vapors. These detectors can be used in medicine, pharmacology, food and the textile industry.
Murat Bektas, Thomas Stöcker, Angelika Mergner, Gunter Hagen, and Ralf Moos
J. Sens. Sens. Syst., 7, 289–297, https://doi.org/10.5194/jsss-7-289-2018, https://doi.org/10.5194/jsss-7-289-2018, 2018
Short summary
Short summary
We prepared BaFe(1-x)-0.01Al0.01TaxO3-δ (BFATx) thick films with x between 0.1 and 0.4 at room temperature using the aerosol deposition method and we measured Seebeck coefficients and conductivities between 600 and 800 °C at different oxygen concentrations. Deposited on a transducer that includes a heater, equipotential layers, and electrode structures, a dual thermoelectric–resistive oxygen sensor with almost temperature-independent characteristics of both measurands was realized using BFAT30.
Jan Erfkamp, Margarita Guenther, and Gerald Gerlach
J. Sens. Sens. Syst., 7, 219–226, https://doi.org/10.5194/jsss-7-219-2018, https://doi.org/10.5194/jsss-7-219-2018, 2018
Short summary
Short summary
We describe a low-cost sensor for the detection of ethanol in alcoholic beverages. The reversible swelling of alcohol-sensitive hydrogels depends on the ethanol concentration. The resulting swelling pressure was detected via piezoresistive sensors. We have tested the swelling properties of the hydrogel (e.g. swelling kinetics, selectivity to other alcohols). Furthermore, the first sensor set-ups were tested and the reversibility of the hydrogel-based piezoresistive sensor was demonstrated.
Vitaly Buckin
J. Sens. Sens. Syst., 7, 207–217, https://doi.org/10.5194/jsss-7-207-2018, https://doi.org/10.5194/jsss-7-207-2018, 2018
Short summary
Short summary
The paper reviews the principles and applications of high-resolution ultrasonic spectroscopy in real-time, non-destructive analysis of molecular transformations, including transitions in polymers, ligand binding, self-assembly, crystallisation, gelation, phase diagrams, monitoring of chemical and biochemical reactions. High precision and useful capabilities of this technique enable its application in a broad range of systems, where other methods often fail or have high analytical cost.
Tobias Reinecke, Johanna-Gabriela Walter, Tim Kobelt, André Ahrens, Thomas Scheper, and Stefan Zimmermann
J. Sens. Sens. Syst., 7, 101–111, https://doi.org/10.5194/jsss-7-101-2018, https://doi.org/10.5194/jsss-7-101-2018, 2018
Short summary
Short summary
A systematic investigation of a split-ring resonator for application as a biosensor is presented. The parameters responsible for the sensitivity of the setup were determined using a new approach to determine the resonance frequency depending on the relative permittivity of the sample. Based on these parameters, the resonator structure was optimized. Subsequently, a split-ring resonator was functionalized with aptamers and a selective detection of CRP could be shown.
Zaven Adamyan, Artak Sayunts, Vladimir Aroutiounian, Emma Khachaturyan, Martin Vrnata, Přemysl Fitl, and Jan Vlček
J. Sens. Sens. Syst., 7, 31–41, https://doi.org/10.5194/jsss-7-31-2018, https://doi.org/10.5194/jsss-7-31-2018, 2018
Short summary
Short summary
In this paper, we have investigated ruthenated MWCNTs/SnO2 thick-film nanocomposite sensors in the presence of propylene glycol (PG), dimethylformamide (DMF) and formaldehyde (FA) vapors in the air. The minimal PG, DMF and FA gas concentrations at which the perceptible signal is registered are 13, 5 and 115 ppm, respectively. The optimal results are shown at 200 °C operating temperature. Dependence of the response on gas concentration is linear in all cases.
Thomas Ritter, Sven Wiegärtner, Gunter Hagen, and Ralf Moos
J. Sens. Sens. Syst., 6, 395–405, https://doi.org/10.5194/jsss-6-395-2017, https://doi.org/10.5194/jsss-6-395-2017, 2017
Short summary
Short summary
A planar thermoelectric gas sensor is modeled. By coupling all influences (fluid flow, gas diffusion, heat transfer, chemical reactions, and electrical properties) a model was set up that mirrors the sensor behavior precisely, as the comparison with experimental data shows. The coupling of 3-D and 1-D geometry enables to calculate the temperature distribution, fluid flow, and the gas concentration distribution in the 3-D model, while the chemical reactions are very accurately calculated in 1-D.
Erik Bunert, Ansgar T. Kirk, Jens Oermann, and Stefan Zimmermann
J. Sens. Sens. Syst., 6, 381–387, https://doi.org/10.5194/jsss-6-381-2017, https://doi.org/10.5194/jsss-6-381-2017, 2017
Short summary
Short summary
Electron capture detectors (ECDs) are widely used for the detection of electron affine substances such as pesticides or chlorofluorocarbons. In this work we present a new non-radioactive ECD and investigate the analytical performance depending on the operating parameters. We achieved limits of detection for 1,1,2-trichloroethane and sevoflurane, which are comparable to radioactive ECDs. Furthermore, a pulsed collector voltage mode was implemented, leading to an extended linear range.
Marco Grossi and Bruno Riccò
J. Sens. Sens. Syst., 6, 303–325, https://doi.org/10.5194/jsss-6-303-2017, https://doi.org/10.5194/jsss-6-303-2017, 2017
Short summary
Short summary
Electrical impedance spectroscopy, in which a sine-wave test voltage or current is applied to the sample under test to measure its impedance over a suitable frequency range, is a powerful technique to investigate the electrical properties of a large variety of materials. This paper presents an updated review of EIS main applications such as measure of bacterial concentration, analysis of human body composition and characterization of food products, as well as other non-biological applications.
Masoud Negahdary, Mahnaz Jafarzadeh, Roya Rahimzadeh, Ghasem Rahimi, and Hamideh Dehghani
J. Sens. Sens. Syst., 6, 259–267, https://doi.org/10.5194/jsss-6-259-2017, https://doi.org/10.5194/jsss-6-259-2017, 2017
Christoph Seitz, Giuliana Beck, Jörg Hennemann, Christian Kandzia, Karl P. Hering, Angelika Polity, Peter J. Klar, Andrej Paul, Thorsten Wagner, Stefanie Russ, and Bernd M. Smarsly
J. Sens. Sens. Syst., 6, 163–170, https://doi.org/10.5194/jsss-6-163-2017, https://doi.org/10.5194/jsss-6-163-2017, 2017
Romy Hoffmann, Matthias Schreiter, and Johannes Heitmann
J. Sens. Sens. Syst., 6, 87–96, https://doi.org/10.5194/jsss-6-87-2017, https://doi.org/10.5194/jsss-6-87-2017, 2017
Short summary
Short summary
Carbon dioxide is a main greenhouse gas and a gas that well-represents air quality. Therefore, it is important to monitor the CO2 concentration in air. Creating an affordable and reliable CO2 sensor is the purpose of this paper. Using a mass-sensitive acoustic sensor (FBAR) we can detect increasing CO2 concentration by a mass increase on the sensor surface. As humidity changes often interfere with these signals the selection of CO2 over humidity changes is another topic addressed in this paper.
Ulrike Schmidt, Carola Jorsch, Margarita Guenther, and Gerald Gerlach
J. Sens. Sens. Syst., 5, 409–417, https://doi.org/10.5194/jsss-5-409-2016, https://doi.org/10.5194/jsss-5-409-2016, 2016
Matthias Schelter, Jens Zosel, Wolfram Oelßner, Ulrich Guth, and Michael Mertig
J. Sens. Sens. Syst., 5, 319–324, https://doi.org/10.5194/jsss-5-319-2016, https://doi.org/10.5194/jsss-5-319-2016, 2016
Mhamed El Achhab and Klaus Schierbaum
J. Sens. Sens. Syst., 5, 273–281, https://doi.org/10.5194/jsss-5-273-2016, https://doi.org/10.5194/jsss-5-273-2016, 2016
Short summary
Short summary
We have developed a preparation technique to form graphite/TiO2/Ti and platinum-graphite/TiO2/Ti solid-state sensors based on plasma electrolytic oxidation (PEO) of titanium foils, whereby a porous titanium oxide layer is formed with well-defined phase composition and a reproducible microstructure. A printing method is used to deposit graphite or catalytically active graphite-platinum electrodes. Our design enables the application of many different detection principles such as calorimetry.
Franz Schubert, Michael Gollner, Jaroslaw Kita, Florian Linseis, and Ralf Moos
J. Sens. Sens. Syst., 5, 205–212, https://doi.org/10.5194/jsss-5-205-2016, https://doi.org/10.5194/jsss-5-205-2016, 2016
Short summary
Short summary
Initial steps to apply a new ceramic multi-layer sensor for a Tian–Calvet calorimeter are shown. The FEM-developed sensor consists of stacked ceramic discs and insulation rings. The functionality of the sensor disc was proven up to 600 °C and the entire stack was tested at room temperature. The resolution was 5 µW and the sensitivity was 8.5 µV mW−1. The new sensor shows similar specifications as commercial devices and presents a good starting point for future high temperature applications.
Martin Leidinger, Joni Huotari, Tilman Sauerwald, Jyrki Lappalainen, and Andreas Schütze
J. Sens. Sens. Syst., 5, 147–156, https://doi.org/10.5194/jsss-5-147-2016, https://doi.org/10.5194/jsss-5-147-2016, 2016
Short summary
Short summary
For the application of indoor air quality monitoring, two types of tungsten oxide gas sensor layers were prepared via pulsed laser deposition. Analysis of the structure of the produced layers showed that they consist of nanoparticles and agglomerates of nanoparticles. The sensors showed significant sensitivity and selectivity towards naphthalene in the ppb concentration range. The results were achieved using temperature cycled operation of the sensors and pattern recognition signal treatment.
Marc-Peter Schmidt, Aleksandr Oseev, Christian Engel, Andreas Brose, Bertram Schmidt, and Sören Hirsch
J. Sens. Sens. Syst., 5, 55–61, https://doi.org/10.5194/jsss-5-55-2016, https://doi.org/10.5194/jsss-5-55-2016, 2016
Short summary
Short summary
The article reports about the development of novel microfluidic sensors that are directly attachable on 3-D polymers. An ability to integrate electrical and fluidic parts into the 3-D platform brings the sensors to a new level of miniaturization. The sensor system is made of a flexible polymer featuring a system of metal electrodes and a rigid polymer carrier with all external macroconnections. To the concentration of ethanol in DI water the sensor system showed the desired sensitivity.
M. Windisch, K.-J. Eichhorn, J. Lienig, G. Gerlach, and L. Schulze
J. Sens. Sens. Syst., 5, 39–53, https://doi.org/10.5194/jsss-5-39-2016, https://doi.org/10.5194/jsss-5-39-2016, 2016
Short summary
Short summary
Hydrogels are swellable polymers, which exhibit superior sensor properties. However, the exploitation of these properties for innovative measurement technology has been prevented by the lack of a manufacturing technique for thin hydogel films that suits industrial needs. We suggest a paradigm change from the current recipe-driven sensor manufacturing to a specification-driven one. Our contributions are optimized processes for a controllable film formation and thermal curing of the hydrogels.
F. Schubert, S. Wollenhaupt, J. Kita, G. Hagen, and R. Moos
J. Sens. Sens. Syst., 5, 25–32, https://doi.org/10.5194/jsss-5-25-2016, https://doi.org/10.5194/jsss-5-25-2016, 2016
Short summary
Short summary
A manufacturing process for a planar binary lambda sensor is shown. By joining the heating and the sensing components via glass soldering with a joining temperature of 850 °C, a laboratory platform has been established that allows the manufacturing of two independent parts in HTCC technology with electrodes that are post-processed at lower temperatures, as is required for mixed-potential sensors. The concept has been proved by comparing the device with a commercial sensor.
S. Fischer, D. Schönauer-Kamin, R. Pohle, M. Fleischer, and R. Moos
J. Sens. Sens. Syst., 4, 321–329, https://doi.org/10.5194/jsss-4-321-2015, https://doi.org/10.5194/jsss-4-321-2015, 2015
Short summary
Short summary
Thimble-type lambda probes that are known for their robustness in harsh exhausts can also be used as an NOx sensor by applying the pulsed polarization technique. This study evaluates in detail the influence of temperature on the NO sensitivity, so that an optimum operating point can be derived. Stepwise NO concentration changes between 0 and 12.5 ppm in synthetic exhausts demonstrate the high potential of this concept.
C. Weigel, M. Schneider, J. Schmitt, M. Hoffmann, S. Kahl, and R. Jurisch
J. Sens. Sens. Syst., 4, 179–186, https://doi.org/10.5194/jsss-4-179-2015, https://doi.org/10.5194/jsss-4-179-2015, 2015
L. Ebersberger and G. Fischerauer
J. Sens. Sens. Syst., 4, 85–90, https://doi.org/10.5194/jsss-4-85-2015, https://doi.org/10.5194/jsss-4-85-2015, 2015
Short summary
Short summary
The current contribution reports on the substrate influence in multilayer metal-oxide chemical sensors. Measurements of the impedance are used to discuss the sensor performance with quartz substrates, (laboratory) glass substrates and substrates covered by silicon-dioxide insulating layers. Numerical experiments based on previous measurement results show that inexpensive glass substrates contribute up to 97% to the overall sensor responses.
S. Baldo, V. Scuderi, L. Tripodi, A. La Magna, S.G. Leonardi, N. Donato, G. Neri, S. Filice, and S. Scalese
J. Sens. Sens. Syst., 4, 25–30, https://doi.org/10.5194/jsss-4-25-2015, https://doi.org/10.5194/jsss-4-25-2015, 2015
M. Braik, C. Dridi, M. Ben Ali, M. Ali, M. Abbas, M. Zabala, J. Bausells, N. Zine, N. Jaffrezic-Renault, and A. Errachid
J. Sens. Sens. Syst., 4, 17–23, https://doi.org/10.5194/jsss-4-17-2015, https://doi.org/10.5194/jsss-4-17-2015, 2015
A. Hannon, Y. Lu, J. Li, and M. Meyyappan
J. Sens. Sens. Syst., 3, 349–354, https://doi.org/10.5194/jsss-3-349-2014, https://doi.org/10.5194/jsss-3-349-2014, 2014
P. Marek, J. J. Velasco-Veléz, T. Doll, and G. Sadowski
J. Sens. Sens. Syst., 3, 291–303, https://doi.org/10.5194/jsss-3-291-2014, https://doi.org/10.5194/jsss-3-291-2014, 2014
Short summary
Short summary
A time-monitoring oxygen sensor based on a diffusion-controlled oxygen reaction of the indicator system methylene blue (MB)/leuco methylene blue (LMB) and riboflavin was embedded in a water-loaded poly(vinyl alcohol) (PVA) matrix. It can be used in packaging, sensors, and biotechnology applications. Since the oxygen diffusion coefficient in the PVA matrix strongly depends on temperature and humidity, two different approaches were developed within this work to compensate for these two effects.
S. Nakagomi, K. Yokoyama, and Y. Kokubun
J. Sens. Sens. Syst., 3, 231–239, https://doi.org/10.5194/jsss-3-231-2014, https://doi.org/10.5194/jsss-3-231-2014, 2014
F. Fedi, F. Ricciardella, M. L. Miglietta, T. Polichetti, E. Massera, and G. Di Francia
J. Sens. Sens. Syst., 3, 241–244, https://doi.org/10.5194/jsss-3-241-2014, https://doi.org/10.5194/jsss-3-241-2014, 2014
Short summary
Short summary
We present the development of a simple and fast method for restoring exhaust graphene-based chemi-resistors used for NO2 detection. Exposing the devices repeatedly to gases or to air for more than two days, an overall worsening of the sensing signal is observed. Starting from this hypothesis and from the observation that nitrogen dioxide is soluble in water, we performed a recovery method consisting in the dipping of exhaust devices into ultrapure water at 100°C for 60 sec.
R. Gruden, A. Buchholz, and O. Kanoun
J. Sens. Sens. Syst., 3, 133–140, https://doi.org/10.5194/jsss-3-133-2014, https://doi.org/10.5194/jsss-3-133-2014, 2014
M. Bastuck, C. Bur, A. Lloyd Spetz, M. Andersson, and A. Schütze
J. Sens. Sens. Syst., 3, 9–19, https://doi.org/10.5194/jsss-3-9-2014, https://doi.org/10.5194/jsss-3-9-2014, 2014
Cited articles
Andringa, A.-M., Vlietstra, N., Smits, E. C. P., Spijkman, M.-J., Gomes, H. L., Klootwijk, J. H., Blom, P. W. M., and de Leeuw, D. M.: Dynamics of charge carrier trapping in NO2 sensors based on ZnO field-effect transistors, Sensor. Actuator. B: Chemical, 171–172, 1172–1179, https://doi.org/10.1016/j.snb.2012.06.062, 2012.
Angelini, E., Grassini, S., Neri, A., Parvis, M., and Perrone, G.: Plastic Optic Fiber Sensor for Cumulative Measurements, in: Proceedings of the International Instrumentation and Measurement Technology Conference – I2MTC 2009, Singapore, 5–7 May 2009, 1666–1670, https://doi.org/10.1109/IMTC.2009.5168723, 2009.
Bai, H. and Shi, G.: Gas Sensors Based on Conducting Polymers, Sensors, 7, 267–307, https://doi.org/10.3390/s7030267, 2007.
Barsan, N., Koziej, D., and Weimar, U.: Metal oxide-based gas sensor research: How to?, Sensor. Actuator. B: Chemical, 121, 18–35, https://doi.org/10.1016/j.snb.2006.09.047, 2007.
Bartscherer, P. and Moos, R.: Improvement of the sensitivity of a conductometric soot sensor by adding a conductive cover layer, Journal of Sensors and Sensor Systems, 2, 95–102, https://doi.org/10.5194/jsss-2-95-2013, 2013.
Beer, S., Helwig, A., Müller, G., Garrido, J., and Stutzmann, M.: Water adsorbate mediated accumulation gas sensing at hydrogenated diamond surfaces, Sensor. Actuator. B: Chemical, 181, 894–903, https://doi.org/10.1016/j.snb.2013.02.072, 2013.
Beulertz, G., Geupel, A., Moos, R., Kubinski, D. J., and Visser, J. H.: Accumulating gas sensor principle – how to come from concentration integration to real amount measurements, Procedia Engineering, 25, 1109–1112, https://doi.org/10.1016/j.proeng.2011.12.273, 2011.
Beulertz, G., Groß, A., Moos, R., Kubinski, D. J., and Visser, J. H.: Determining the total amount of NOx in a gas stream – Advances in the accumulating gas sensor principle, Sensor. Actuator. B: Chemical, 175, 157–162, https://doi.org/10.1016/j.snb.2012.02.017, 2012.
Bhalla, V., Singh, H., and Kumar, M.: Facile Cyclization of Terphenyl to Triphenylene: A New Chemodosimeter for Fluoride Ions, Organic Lett., 12, 628–631, https://doi.org/10.1021/ol902861b, 2010.
Brandenburg, A., Kita, J., Groß, A., and Moos, R.: Novel tube-type LTCC transducers with buried heaters and inner interdigitated electrodes as a platform for gas sensing at various high temperatures, Sensor. Actuator. B: Chemical, 189, 80–88, https://doi.org/10.1016/j.snb.2012.12.119, 2013.
Brunet, J., Talazac, L., Battut, V., Pauly, A., Blanc, J. P., Germain, J. P., Pellier, S., and Soulier, C.: Evaluation of atmospheric pollution by two semiconductor gas sensors, Thin Solid Films, 391, 308–313, https://doi.org/10.1016/S0040-6090(01)01001-X, 2001.
Brunet, J., Garcia Parra, V., Pauly, A., Varenne, C., and Lauron, B.: An optimized gas sensor microsystem for accurate and real-time measurement of nitrogen dioxide at ppb level, Sensor. Actuator. B: Chemical, 134, 632–639, https://doi.org/10.1016/j.snb.2008.06.010, 2008.
Chen, R., Morris, H. R., and Whitmore, P. M.: Fast Detection of Hydrogen Sulfide Gas in the ppmv Range with Silver Nanoparticles Films at Ambient Conditions, Sensor. Actuator. B: Chemical, 186, 431–438, https://doi.org/10.1016/j.snb.2013.05.075, 2013.
Corcoran, P. and Shurmer, H. V.: An intelligent gas sensor, Sensor. Actuator. A: Physical, 41–42, 192–197, https://doi.org/10.1016/0924-4247(94)80110-X, 1994.
Dasgupta, P. K., Genfa, Z., Poruthoor, S. K., Caldwell, S., Dong, S., and Liu, S.-Y.: High-Sensitive Gas Sensors Based on Gas-Permeable Liquid Core Waveguides and Long-Path Absorbance Detection, Anal. Chem., 70, 4661–4669, https://doi.org/10.1021/ac980803t, 1998.
Eigenmann, F., Maciejewski, and Baiker, A.: Gas adsorption studied by pulse thermal analysis, Thermochimica Acta, 359, 131–141, https://doi.org/10.1016/S0040-6031(00)00516-5, 2000.
Franke, M. E., Simon, U., Moos, R., Knezevic, A., Müller, R., and Plog, C.: Development and working principle of an ammonia gas sensor based on a refined model for solvate supported proton transport in zeolites, Phys. Chem. Chem. Phy., 5, 5195–5198, https://doi.org/10.1039/B307502H, 2003.
Fremerey, P., Jess, A., and Moos, R.: Direct in-situ detection of sulfur loading on fixed bed catalysts, in: Proceedings of the 14th International Meeting on Chemical Sensors – IMCS 2012, Nuremberg, Germany, 20–23 May 2012, 76–79, https://doi.org/10.5162/IMCS2012/1.1.5, 2012.
Geupel, A., Schönauer, D., Röder-Roith, U., Kubinski, D. J., Mulla, S., Ballinger, T. H., Chen, H.-Y., Visser, J. H., and Moos, R.: Integrating nitrogen oxide sensor: A novel concept for measuring low concentrations in the exhaust gas, Sensor. Actuator. B: Chemical, 145, 756–761, https://doi.org/10.1016/j.snb.2010.01.036, 2010.
Geupel, A., Kubinski, D. J., Mulla, S., Ballinger, T. H., Chen, H.-Y., Visser, J. H., and Moos, R.: Integrating NOx Sensor for Automotive Exhausts – A Novel Concept, Sensor Letters, 9, 311–315, https://doi.org/10.1166/sl.2011.1471, 2011.
Göpel, W.: New materials and transducers for chemical sensors, Sensor. Actuator. B: Chemical, 18–19, 1–21, https://doi.org/10.1016/0925-4005(94)87049-7, 1994.
Groß, A., Beulertz, G., Marr, I., Kubinski, D. J., Visser, J. H., and Moos, R.: Dual Mode NOx Sensor: Measuring Both the Accumulated Amount and Instantaneous Level at Low Concentrations, Sensors, 12, 2831–2850, https://doi.org/10.3390/s120302831, 2012a.
Groß, A., Richter, M., Kubinski, D. J., Visser, J. H., and Moos, R.: The Effect of the Thickness of the Sensitive Layer on the Performance of the Accumulating NOx Sensor, Sensors, 12, 12329–12346, https://doi.org/10.3390/s120912329, 2012b.
Groß, A., Bishop, S. R., Yang, D. J., Tuller, H. L., and Moos, R.: The electrical properties of NOx-storing carbonates during NOx exposure, Solid State Ionics, 225, 317–323, https://doi.org/10.1016/j.ssi.2012.05.009, 2012c.
Groß, A., Hanft, D., Beulertz, G., Marr, I., Kubinski, D. J., Visser, J. H., and Moos, R.: The effect of SO2 on the sensitive layer of a NOx dosimeter, Sensor. Actuator. B: Chemical, 187, 153–161, https://doi.org/10.1016/j.snb.2012.10.039, 2012d.
Groß, A., Kremling, M., Marr, I., Kubinski, D. J., Visser, J. H., Tuller, H. L., and Moos, R.: Dosimeter-Type NOx Sensing Properties of KMnO4 and Its Electrical Conductivity during Temperature Programmed Desorption, Sensors, 13, 4428–4449, https://doi.org/10.3390/s130404428, 2013a.
Groß, A., Weller, T., Tuller, H. L., and Moos, R.: Electrical conductivity study on NOx trap materials BaCO3 and K2CO3/La-Al2O3 during NOx exposure, Sensor. Actuator. B: Chemical, 187, 461–470, https://doi.org/10.1016/j.snb.2013.01.083, 2013b.
Hagen, G., Feistkorn, C., Wiegärtner, S., Heinrich, A., Brüggemann, D., and Moos, R.: Conductometric Soot Sensor for Automotive Exhausts: Initial Studies, Sensors, 10, 1589–1598, https://doi.org/10.3390/s100301589, 2010.
Helwig, A., Müller, G., Weidemann, O., Härtl, A., Garrido, J. A., and Eickhoff, M.: Gas Sensing Interactions at Hydrogenated Diamond Surfaces, IEEE Sensors Journal, 7, 1349–1353, https://doi.org/10.1109/JSEN.2007.905019, 2007.
Helwig, A., Müller, G., Garrido, J. A., and Eickhoff, M.: Gas sensing properties of hydrogen-terminated diamond, Sensor. Actuator. B: Chemical, 133, 156–165, https://doi.org/10.1016/j.snb.2008.02.007, 2008.
Helwig, A., Beer, S., and Müller, G.: Breathing mode gas detection, Sensor. Actuator. B: Chemical, 179, 131–139, https://doi.org/10.1016/j.snb.2012.07.088, 2013.
Hennemann, J., Sauerwald, T., Kohl, C.-D., Wagner, T., Bognitzki, M., and Greiner, A.: Electrospun copper oxide nanofibers for H2S dosimetry, Phys. Status Solidi A, 209, 911–916, https://doi.org/10.1002/pssa.201100588, 2012a.
Hennemann, J., Sauerwald, T., Wagner, T., Kohl, C.-D., Dräger, J., and Russ, S.: Electrospun Copper(II)oxide Fibers as Highly Sensitive and Selective Sensor for Hydrogen Sulfide Utilizing Percolation Effects, in: Proceedings of the 14th International Meeting on Chemical Sensors – IMCS 2012, Nuremberg, Germany, 20–23 May 2012, 197–200, https://doi.org/10.5162/IMCS2012/2.3.4, 2012b.
Hennemann, J., Sauerwald, T., Wagner, T., Kohl, C.-D., Dräger, J., and Russ, S.: Gassensoren für Schwefelwasserstoff mit integrierender Funktion, in: Proceedings of the XXVI. Messtechnisches Symposium des Arbeitskreises der Hochschullehrer für Messtechnik, Aachen, Germany, 20–22 September 2012, 5–16, 2012c.
Husted, H., Roth, G., Nelson, S., Hocken, L., Fulks, G., and Racine, D.: Sensing of Particulate Matter for On-Board Diagnosis of Particulate Filters, SAE paper 2012-01-0372, https://doi.org/10.4271/2012-01-0372, 2012.
Jung, W., Sahner, K., Leung, A., and Tuller, H. L.: Acoustic wave-based NO2 sensor: Ink-jet printed active layer, Sensor. Actuator. B: Chemical, 141, 485–490, https://doi.org/10.1016/j.snb.2009.07.010, 2009.
Katayama, S., Yamada, N., and Awano, M.: Preparation of alkaline-earth metal silicates from gels and their NOx-adsorption behavior, Journal of the European Ceramic Society, 24, 421–425, https://doi.org/10.1016/S0955-2219(03)00211-5, 2004.
Kita, J., Brandenburg, A., Groß, A., and Moos, R.: Novel tube-type LTTC transducers with buried heaters and inner interdigitated electrodes for high-temperatures gas sensors, Proc. Eng., 47, 60–63, https://doi.org/10.1016/j.proeng.2012.09.084, 2012.
Klug, A., Denk, M., Bauer, T., Sandholzer, M., Scherf, U., Slugovc, C., and List, E. J. W.: Organic field-effect transistor based sensors with sensitive gate dielectrics used for low-concentration ammonia detection, Organic Electronics, 14, 500–504, https://doi.org/10.1016/j.orgel.2012.11.030, 2013.
Kohl, D.: Function and applications of gas sensors, J. Phys. D: Applied Physics, 34, R125–R149, https://doi.org/10.1088/0022-3727/34/19/201, 2001.
Kondo, A., Yokoi, S., Sakurai, T., Nishikawa, S., Egami, T., Tokuda, M., and Sakuma, T.: New Particulate Matter Sensor for On Board Diagnosis, SAE paper 2011-01-0302, https://doi.org/10.4271/2011-01-0302, 2011.
Kubinski, D. J. and Visser J. H.: Sensor and method for determining the ammonia loading of a zeolite SCR catalyst, Sensor. Actuator. B: Chemical, 130, 425–429, https://doi.org/10.1016/j.snb.2007.09.007, 2008.
Li, J., Lu, Y., Ye, Q., Cinke, M., Han, J., and Meyyappan, M.: Carbon Nanotube Sensors for Gas and Organic Vapor Detection, Nano Letters, 3, 929–933, https://doi.org/10.1021/nl034220x, 2003.
Liu, X., Cheng, S., Liu, H., Hu, S., Zhang, D., and Ning, H.: A Survey on Gas Sensing Technology, Sensors, 12, 9635–9665, https://doi.org/10.3390/s120709635, 2012.
Mangu, R., Rajaputra, S., Clore, P., Qian, D., Andrews, R., and Singh, V. P.: Ammonia sensing properties of multiwalled carbon nanotubes embedded in porous alumina templates, Materials Science and Engineering B, 174, 2–8, https://doi.org/10.1016/j.mseb.2010.03.003, 2010.
Marr, I., Stöcker, T., and Moos, R.: Resistives Gasdosimeter auf Basis von PEDOT:PSS zur Detektion von NO und NO2, in: Proceedings of the 11th Dresdner Sensor-Symposium, Dresden, Germany, 9–11 December 2013, 317–320, https://doi.org/10.5162/11dss2013/F3, 2013.
Martin, S. J., Frye, G. C., Spates, J. J., and Butler, M. A.: Gas Sensing with Acoustic Devices, in: Proceedings of the IEEE Ultrasonics Symposium 1996, 1, San Antonio, Texas/USA, 3–6 November 1996, 423–434, https://doi.org/10.1109/ULTSYM.1996.584005, 1996.
Maruo, Y. Y.: Measurement of ambient ozone using newly developed porous glass sensor, Sensor. Actuator. B: Chemical, 126, 485–491, https://doi.org/10.1016/j.snb.2007.03.041, 2007.
Maruo, Y. Y., Kunioka, T., Akaoka, K., and Nakamura, J.: Development and evaluation of ozone detection paper, Sensor. Actuator. B: Chemical, 135, 575–580, https://doi.org/10.1016/j.snb.2008.09.016, 2009.
Mathieu, Y., Tzanis, L., Soulard, M., Patarin, J., Vierling, M., and Molière, M.: Adsorption of SOx by oxide materials: A review, Fuel Proc. Technol., 114, 81–100, https://doi.org/10.1016/j.fuproc.2013.03.019, 2013.
Matsuguchi, M., Kadowaki, Y., and Tanaka, M.: A QCM-based NO2 gas detector using morpholine-functional cross-linked copolymer coatings, Sensor. Actuator. B: Chemical, 108, 572–575, https://doi.org/10.1016/j.snb.2004.11.044, 2005.
Mattoli, V., Mazzolai, B., Raffa, V., Mondini, A., and Dario, P.: Design of a new real-time dosimeter to monitor personal exposure to elemental gaseous mercury, Sensor. Actuator. B: Chemical, 123, 158–167, https://doi.org/10.1016/j.snb.2006.08.004, 2007.
Moos, R., Geupel, A., Visser, J. H., and Kubinski, D. J.: Vorrichtung und Verfahren zur Detektion einer Menge einer Gaskomponente, German Patent Application, DE 10 2010 023 523 A1, 2010.
Moos, R., Beulertz, G., Geupel, A., Visser, J. H., and Kubinski, D. J.: Vorrichtung und Verfahren zur Detektion der Menge und der Konzentration einer Gaskomponente, German Patent Application, DE 10 2012 206 788 A1, 2012.
Mubeen, S., Lai, M., Zhang, T., Lim, J.-H., Mulchandani, A., Deshusses, M. A., and Myung, N. V.: Hybrid tin oxide-SWNT nanostructures based gas sensor, Electrochimica Acta, 92, 484–490, https://doi.org/10.1016/j.electacta.2013.01.029, 2013.
Mukherjee, K., Gaur, A. P. S., and Majumder, S. B.: Investigations on irreversible- and reversible-type gas sensing for ZnO and Mg0.5Zn0.5Fe2O4 chemi-resistive sensors, J. Phys. D: Applied Physics, 45, 505306, https://doi.org/10.1088/0022-3727/45/50/505306, 2012.
Nieuwenhuizen, M. S. and Harteveld, J. L. N.: Studies on a surface acoustic wave (SAW) dosimeter sensor for organophosphorous nerve agents, Sensor. Actuator. B: Chemical, 40, 167–173, https://doi.org/10.1016/S0925-4005(97)80257-2, 1997.
Ochs, T., Schittenhelm, H., Genssle, A., and Kamp, B.: Particulate matter sensor for on board diagnostics (OBD) of diesel particulate filters (DPF), SAE paper 2010-01-0307, https://doi.org/10.4271/2010-01-0307, 2010.
Ong, K. G., Zeng, K, and Grimes, C. A.: A Wireless, Passive Carbon Nanotube-Based Gas Sensor, IEEE Sensors Journal, 2, 82–88, https://doi.org/10.1109/JSEN.2002.1000247, 2002.
Padilla, M., Perera, A., Montoliu, I., Chaudry, A., Persaud, K., and Marco, S.: Drift compensation of gas sensor array data by Orthogonal Signal Correction, Chemometrics and Intelligent Laboratory Systems, 100, 28–35, https://doi.org/10.1016/j.chemolab.2009.10.002, 2010.
Padma, N., Joshi, A., Singh, A., Deshpande, S. K., Aswal, D. K., Gupta, S. K., and Yakhmi, J. V.: NO2 sensors with room temperature operation and long term stability using copper phthalocyanine thin films, Sensor. Actuator. B: Chemical, 143, 246–252, https://doi.org/10.1016/j.snb.2009.07.044, 2009.
Rettig, F., Moos, R., and Plog, C.: Sulfur adsorber for thick-film exhaust gas sensors, Sensor. Actuator. B: Chemical, 93, 36–42, https://doi.org/10.1016/S0925-4005(03)00334-4, 2003.
Reyes, L. F., Hoel, A., Saukko, S., Heszler, P., Lantto, V., and Granqvist, C. G.: Gas sensor response of pure and activated WO3 nanoparticle films made by advanced reactive gas deposition, Sensor. Actuator. B: Chemical, 117, 128–134, https://doi.org/10.1016/j.snb.2005.11.008, 2006.
Roadman, M. J., Scudlark, J. R., Meisinger, J. J., and Ullman, W. J.: Validation of Ogawa passive samplers for the determination of gaseous ammonia concentrations in agricultural settings, Atmos. Environ., 37, 2317–2325, https://doi.org/10.1016/S1352-2310(03)00163-8, 2003.
Rodríguez-González, L. and Simon, U.: NH3-TPD measurements using a zeolite-based sensor, Measurement Science and Technology, 21, 027003, https://doi.org/10.1088/0957-0233/21/2/027003, 2010.
Rodríguez-González, L., Rodríguez-Castellón, E., Jiménez-López, A., and Simon, U.: Correlation of TPD and impedance measurements on the desorption of NH3 from zeolite H-ZSM-5, Solid State Ionics, 179, 1968–1973, https://doi.org/10.1016/j.ssi.2008.06.007, 2008.
Rossé, G., Raoult, F., and Fortin, B.: Regeneration of CdSe Thin Films After Oxygen Chemisorption, Thin Solid Films, 111, 175–181, https://doi.org/10.1016/0040-6090(84)90485-1, 1984.
Sahner, K., Hagen, G., Schönauer, D., Reiß, S., and Moos, R.: Zeolites – Versatile materials for gas sensors, Solid State Ionics, 179, 2416–2423, https://doi.org/10.1016/j.ssi.2008.08.012, 2008.
Sasaki, D. Y., Singh, S., Cox, J. D, and Pohl, P. I.: Fluorescence detection of nitrogen dioxide with perylene/PMMA thin films, Sensor. Actuator. B: Chemical, 72, 51–55, https://doi.org/10.1016/S0925-4005(00)00632-8, 2001.
Sauerwald, T., Hennemann, J., Kohl, C.-D., Wagner, T., and Russ, S.: H2S detection utilizing percolation effects in copper oxide, in: Proceedings of Sensor 2013, Nuremberg, Germany, 14–16 May 2013, E6.4, https://doi.org/10.5162/sensor2013/E6.4, 2013.
Schütze, A., Pieper, N., and Zacheja, J.: Quantitative ozone measurement using a phthalocyanine thin-film sensor and dynamic signal evaluation, Sensor. Actuator. B: Chemical, 23, 215–217, https://doi.org/10.1016/0925-4005(94)01281-L, 1995.
Seethapathy, S., Górecki, T., and Li, X.: Passive sampling in environmental analysis, J. Chromatogr. A, 1184, 234–253, https://doi.org/10.1016/j.chroma.2007.07.070, 2008.
Semancik, S., Cavicchi, R. E., Wheeler, M. C., Tiffany, J. E., Poirier, G. E., Walton, R. M., Suehle, J. S., Panchapakesan, B., and DeVoe, D. L.: Microhotplate platforms for chemical sensor research, Sensor. Actuator. B: Chemical, 77, 579–591, https://doi.org/10.1016/S0925-4005(01)00695-5, 2001.
Shu, J. H.: Passive Chemiresistor Sensor Based on Iron (II) Phthalocyanine Thin Films for Monitoring of Nitrogen Dioxide, Dissertation, Auburn University, Auburn, Alabama/USA, 13 December 2010.
Shu, J. H., Wikle, H. C., and Chin, B. A.: Passive chemiresistor sensor based on iron (II) phthalocyanine thin films for monitoring of nitrogen dioxide, Sensor. Actuator. B: Chemical, 148, 498–503, https://doi.org/10.1016/j.snb.2010.05.017, 2010.
Shu, J. H., Wikle, H. C., and Chin, B. A.: Passive Detection of Nitrogen Dioxide Gas by Relative Resistance Monitoring of Iron (II) Phthalocyanine Thin Films, IEEE Sensors Journal, 11, 56–61, https://doi.org/10.1109/JSEN.2010.2051024, 2011.
Simon, I., Bârsan, N., Bauer, M., and Weimar, U.: Micromachined metal oxide gas sensors: opportunities to improve sensor performance, Sensor. Actuator. B: Chemical, 73, 1–26, https://doi.org/10.1016/S0925-4005(00)00639-0, 2001.
Simon, U., Flesch, U., Maunz, W., Müller, R., and Plog, C.: The effect of NH3 on the ionic conductivity of dehydrated zeolites Na beta and H beta, Microporous and Mesoporous Materials, 21, 111–116, https://doi.org/10.1016/S1387-1811(97)00056-5, 1998.
Simons, T. and Simon, U.: Zeolite H-ZSM-5: A Microporous Proton Conductor for the in situ Monitoring of DeNOx-SCR, in: Proceedings of the Materials Research Society Spring Meeting 2011, 1330, San Francisco, California/USA, 25–29 April 2011, mrss11-1330-j01-03-k03-03, https://doi.org/10.1557/opl.2011.1337, 2011.
Simons, T. and Simon, U.: Zeolites as nanoporous, gas-sensitive materials for in situ monitoring of DeNOx-SCR, Beilstein Journal of Nanotechnology, 3, 667–673, https://doi.org/10.3762/bjnano.3.76, 2012.
Sircar, A., Mallik, B., and Misra, T. N.: Effect of Adsorption of Vapours on the Electrical Conductivity of a Series of Some Naphthyl Polyenes: Adsorption and Desorption Kinetics, J. Phys. Chem. Solids, 44, 401–405, https://doi.org/10.1016/0022-3697(83)90067-7, 1983.
Small IV, W., Maitland, D. J., Wilson, T. S., Bearinger, J. P., Letts, S. A., and Trebes, J. E.: Development of a prototype optical hydrogen gas sensor using a getter-doped polymer transducer for monitoring cumulative exposure: Preliminary results, Sensor. Actuator. B: Chemical, 139, 375–379, https://doi.org/10.1016/j.snb.2009.03.020, 2009.
Stamires, D. N.: Effect of Adsorbed Phases on the Electrical Conductivity of Synthetic Crystalline Zeolites, J. Chem. Phys., 36, 3174–3181, https://doi.org/10.1063/1.1732446, 1962.
Tamaki, J., Fujimori, K., Miura, N., and Yamazoe, N.: Sensing characteristics of semiconductor barium carbonate sensor to nitrogen oxides at elevated temperature, in: Proceedings of the 2nd East Asian Conference on Chemical Sensors, Xian, China, 5–8 October 1995, 1995.
Tanaka, T., Ohyama, T., Maruo, Y. Y., and Hayashi, T.: Coloration reactions between NO2 and organic compounds in porous glass for cumulative gas sensor, Sensor. Actuator. B: Chemical, 47, 65–69, https://doi.org/10.1016/S0925-4005(98)00051-3, 1998.
Tanaka, T., Guilleux, A., Ohyama, T., Maruo, Y. Y., and Hayashi, T.: A ppb-level NO2 gas sensor using coloration reactions in porous glass, Sensor. Actuator. B: Chemical, 56, 247–253, https://doi.org/10.1016/S0925-4005(99)00185-9, 1999.
Ulrich, M., Bunde, A., and Kohl, C.-D.: Percolation and gas sensitivity in nanocrystalline metal oxide films, Appl. Phys. Lett., 85, 242–244, https://doi.org/10.1063/1.1769071, 2004.
Varghese, O. K., Kichambre, P. D., Gong, D., Ong, K. G., Dickey, E. C., and Grimes, C. A.: Gas sensing characteristics of multi-wall carbon nanotubes, Sensor. Actuator. B: Chemical, 81, 32–41, https://doi.org/10.1016/S0925-4005(01)00923-6, 2001.
Varshney, C. K. and Singh, A. P.: Passive Samplers for NOx Monitoring: A Critical Review, The Environmentalist, 23, 127–136, https://doi.org/10.1023/A:1024883620408, 2003.
Wagner, T., Haffer, S., Weinberger, C., Klaus, D., and Tiemann, M.: Mesoporous materials as gas sensors, Chem. Soc. Rev., 42, 4036–4053, https://doi.org/10.1039/c2cs35379b, 2013.
Weigl, M., Roduner, C., and Lauer, T.: Particle-Filter-Onboard-Diagnosis by Means of a Soot-Sensor Downstream of the Particle-Filter, in: Proceedings of the 6th International Exhaust Gas and Particulate Emissions Forum, Ludwigsburg, Germany, 9–10 March 2010, 62–69, 2010.
Williams, D. E.: Semiconducting oxides as gas-sensitive resistors, Sensor. Actuator. B: Chemical, 57, 1–16, https://doi.org/10.1016/S0925-4005(99)00133-1, 1999.
Yamazoe, N.: Toward innovations of gas sensor technology, Sensor. Actuator. B: Chemical, 108, 2–14, https://doi.org/10.1016/j.snb.2004.12.075, 2005.
Yamazoe, N. and Shimanoe, K.: Overview of Gas Sensor Technology, in: Science and Technology of Chemiresistor Gas Sensors, edited by: Aswal, D. K. and Gupta, S. K., Nova Science Publishers Inc., New York, 2007.
Yamazoe, N., Fuchigami, J., Kishikawa, M., and Seiyama, T.: Interactions of Tin Oxide Surface with O2, H2O and H2, Surface Science, 86, 335–344, https://doi.org/10.1016/0039-6028(79)90411-4, 1979.
Yamazoe, N., Sakai, G., and Shimanoe, K.: Oxide Semiconductor Gas Sensors, Catalysis Surveys from Asia, 7, 63–75, https://doi.org/10.1023/A:1023436725457, 2003.