Articles | Volume 3, issue 2
https://doi.org/10.5194/jsss-3-355-2014
© Author(s) 2014. This work is distributed under
the Creative Commons Attribution 3.0 License.
the Creative Commons Attribution 3.0 License.
https://doi.org/10.5194/jsss-3-355-2014
© Author(s) 2014. This work is distributed under
the Creative Commons Attribution 3.0 License.
the Creative Commons Attribution 3.0 License.
Development of a portable active long-path differential optical absorption spectroscopy system for volcanic gas measurements
Istituto Nazionale di Geofisica e Vulcanologia – Sezione di Palermo – Via Ugo La Malfa, 153, 90146 Palermo, Italy
U.S. Geological Survey, Cascades Volcano Observatory, 1300 SE Cardinal Ct S100, Vancouver, Washington 98683, USA
S. Inguaggiato
Istituto Nazionale di Geofisica e Vulcanologia – Sezione di Palermo – Via Ugo La Malfa, 153, 90146 Palermo, Italy
Related authors
Santiago Arellano, Bo Galle, Fredy Apaza, Geoffroy Avard, Charlotte Barrington, Nicole Bobrowski, Claudia Bucarey, Viviana Burbano, Mike Burton, Zoraida Chacón, Gustavo Chigna, Christian Joseph Clarito, Vladimir Conde, Fidel Costa, Maarten De Moor, Hugo Delgado-Granados, Andrea Di Muro, Deborah Fernandez, Gustavo Garzón, Hendra Gunawan, Nia Haerani, Thor H. Hansteen, Silvana Hidalgo, Salvatore Inguaggiato, Mattias Johansson, Christoph Kern, Manne Kihlman, Philippe Kowalski, Pablo Masias, Francisco Montalvo, Joakim Möller, Ulrich Platt, Claudia Rivera, Armando Saballos, Giuseppe Salerno, Benoit Taisne, Freddy Vásconez, Gabriela Velásquez, Fabio Vita, and Mathieu Yalire
Earth Syst. Sci. Data, 13, 1167–1188, https://doi.org/10.5194/essd-13-1167-2021, https://doi.org/10.5194/essd-13-1167-2021, 2021
Short summary
Short summary
This study presents a dataset of volcanic sulfur dioxide (SO2) emissions from 2005–2017. Measurements were obtained by Network for Observation of Volcanic and Atmospheric Change (NOVAC) scanning differential optical absorption spectrometer (ScanDOAS) instruments at 32 volcanoes and processed using a standardized procedure. We show statistics of volcanic gas emissions under a variety of conditions and compare them with averages derived from measurements from space and historical inventories.
Santiago Arellano, Bo Galle, Fredy Apaza, Geoffroy Avard, Charlotte Barrington, Nicole Bobrowski, Claudia Bucarey, Viviana Burbano, Mike Burton, Zoraida Chacón, Gustavo Chigna, Christian Joseph Clarito, Vladimir Conde, Fidel Costa, Maarten De Moor, Hugo Delgado-Granados, Andrea Di Muro, Deborah Fernandez, Gustavo Garzón, Hendra Gunawan, Nia Haerani, Thor H. Hansteen, Silvana Hidalgo, Salvatore Inguaggiato, Mattias Johansson, Christoph Kern, Manne Kihlman, Philippe Kowalski, Pablo Masias, Francisco Montalvo, Joakim Möller, Ulrich Platt, Claudia Rivera, Armando Saballos, Giuseppe Salerno, Benoit Taisne, Freddy Vásconez, Gabriela Velásquez, Fabio Vita, and Mathieu Yalire
Earth Syst. Sci. Data, 13, 1167–1188, https://doi.org/10.5194/essd-13-1167-2021, https://doi.org/10.5194/essd-13-1167-2021, 2021
Short summary
Short summary
This study presents a dataset of volcanic sulfur dioxide (SO2) emissions from 2005–2017. Measurements were obtained by Network for Observation of Volcanic and Atmospheric Change (NOVAC) scanning differential optical absorption spectrometer (ScanDOAS) instruments at 32 volcanoes and processed using a standardized procedure. We show statistics of volcanic gas emissions under a variety of conditions and compare them with averages derived from measurements from space and historical inventories.
S. Beirle, C. Hörmann, M. Penning de Vries, S. Dörner, C. Kern, and T. Wagner
Atmos. Chem. Phys., 14, 8309–8322, https://doi.org/10.5194/acp-14-8309-2014, https://doi.org/10.5194/acp-14-8309-2014, 2014
P. Lübcke, N. Bobrowski, S. Illing, C. Kern, J. M. Alvarez Nieves, L. Vogel, J. Zielcke, H. Delgado Granados, and U. Platt
Atmos. Meas. Tech., 6, 677–696, https://doi.org/10.5194/amt-6-677-2013, https://doi.org/10.5194/amt-6-677-2013, 2013
Related subject area
Sensor principles and phenomena: Optical and infrared sensors
Miniaturized two-chamber photoacoustic CO2 sensor with a wafer-bonded MEMS (micro-electro-mechanical systems) detector
Concatenated Bragg grating fiber-optic sensors for simultaneous measurement of curvature, temperature, and axial pressure
Optical and tactile measurements on SiC sample defects
Investigation of the degree of cross-linking of polyethylene and thermosets using absolute optical spectroscopy and Raman microscopy
Compact silicon-based attenuated total reflection (ATR) sensor module for liquid analysis
Real-time active-gas imaging of small gas leaks
Non-invasive blood sugar detection by cost-effective capacitance spectroscopy
Resonant photoacoustic cells for laser-based methane detection
Fabrication of integrated polysilicon waveguides for mid-infrared absorption sensing
Near-infrared LED system to recognize road surface conditions for autonomous vehicles
Characterization of specular freeform surfaces from reflected ray directions using experimental ray tracing
Iterative feature detection of a coded checkerboard target for the geometric calibration of infrared cameras
The size-of-source effect in thermography
Method for fast determination of the angle of ionizing radiation incidence from data measured by a Timepix3 detector
Comparison of laser-based photoacoustic and optical detection of methane
Metrological characterization and calibration of thermographic cameras for quantitative temperature measurement
Detection of plastics in water based on their fluorescence behavior
Analysis of photoelastic properties of monocrystalline silicon
Evaluation of optical fibre sensors in the electrical domain
Infrared-based sensor system for contactless monitoring of wetness and ice
Miniaturized photoacoustic detection of organofluorine-based refrigerants
Characterization, calibration and validation of an industrial emissometer
Measurement of the absolute spectral responsivity in the mid-infrared based on the cryogenic electrical substitution radiometer and an optimized thermopile detector
Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy
Validation of three-component wind lidar sensor for traceable highly resolved wind vector measurements
Comparison between different fiber coatings and adhesives on steel surfaces for distributed optical strain measurements based on Rayleigh backscattering
Crack luminescence as an innovative method for detection of fatigue damage
Temperature sensing in underground facilities by Raman optical frequency domain reflectometry using fiber-optic communication cables
Evaluation of the pH-sensitive swelling of a hydrogel by means of a plasmonic sensor substrate
Temperature reconstruction of infrared images with motion deblurring
TSA infrared measurements for stress distribution on car elements
Transmitted light pH optode for small sample volumes
Purity monitoring in medical gas supply lines with quantum cascade laser technology
Efficient thermal infrared emitter with high radiant power
Refractive index sensing of gases based on a one-dimensional photonic crystal nanocavity
Thermal imaging as a modern form of pyrometry
Multi-channel IR sensor system for determination of oil degradation
Simon Gaßner, Simon Essing, David Tumpold, Katrin Schmitt, and Jürgen Wöllenstein
J. Sens. Sens. Syst., 13, 219–226, https://doi.org/10.5194/jsss-13-219-2024, https://doi.org/10.5194/jsss-13-219-2024, 2024
Short summary
Short summary
This article describes a small prototype sensor designed to sense carbon dioxide (CO2) levels for indoor air quality monitoring. The device uses a photoacoustic detector fabricated using a wafer-bonding process. This allows for high-volume production of the sensors. The prototype presented is small in size and can detect CO2 levels as low as 81 ppm with a response time of 53 s. Our results show suitability for application in indoor air quality control systems.
Sohrab Shojaei Khatouni, Sven Zakowski, Reza Hosseini Vedad, Mustafa Masjedi, Akram Askar, Jan Christian Eli Ewald, and Hoc Khiem Trieu
J. Sens. Sens. Syst., 13, 147–155, https://doi.org/10.5194/jsss-13-147-2024, https://doi.org/10.5194/jsss-13-147-2024, 2024
Short summary
Short summary
This study introduces four sensors utilizing multiple fiber Bragg grating constellations embedded in a silicon dioxide single-mode fiber for simultaneous pressure, temperature, and bending curvature measurement. By varying grating constellation, dimensions, and materials, researchers optimized sensor performance. Results indicate that the optimal configuration involves a high cladding-to-coating ratio, less-stiff coating, and the combination of two gratings to form a Fabry–Pérot interferometer.
Jana Grundmann, Bernd Bodermann, Elena Ermilova, Matthias Weise, Andreas Hertwig, Petr Klapetek, Jila Rafighdoost, and Silvania F. Pereira
J. Sens. Sens. Syst., 13, 109–121, https://doi.org/10.5194/jsss-13-109-2024, https://doi.org/10.5194/jsss-13-109-2024, 2024
Short summary
Short summary
In power electronics, materials like silicon carbide (SiC) are increasingly being used instead of silicon. They have a lot of advantages but also require defect inspection with high accuracy. Different defect types on SiC samples are measured with various methods to determine which one is most suitable for which defect. In conclusion, each examined measurement method is sensitive to the studied defects, although they differ in speed and specialized application fields.
Florian Bergmann, Norbert Halmen, Claudia Scalfi-Happ, Dominik Reitzle, Alwin Kienle, Linda Mittelberg, Benjamin Baudrit, Thomas Hochrein, and Martin Bastian
J. Sens. Sens. Syst., 12, 175–185, https://doi.org/10.5194/jsss-12-175-2023, https://doi.org/10.5194/jsss-12-175-2023, 2023
Short summary
Short summary
In this work, the determination of the degree of cross-linking was investigated using absolute optical measurements with an integrating sphere and Raman spectroscopy. PE-Xc, on the basis of HDPE and UHMWPE and various thermosets, was examined. Laboratory methods (e.g. wet chemical analysis, DSC, and DEA) were used for comparison. A good correlation of the results of the optical methods with those of the laboratory methods could be shown and serves as a basis for further investigations.
Armin Lambrecht, Carsten Bolwien, Hendrik Fuhr, Gerd Sulz, Annett Isserstedt-Trinke, André Magi, Steffen Biermann, and Jürgen Wöllenstein
J. Sens. Sens. Syst., 12, 123–131, https://doi.org/10.5194/jsss-12-123-2023, https://doi.org/10.5194/jsss-12-123-2023, 2023
Short summary
Short summary
Infrared spectroscopy is great for determining the composition of liquids. Combined with attenuated total reflection (ATR), one can just put the sample on the sensitive surface. We made a compact device with a diamond-coated silicon ATR crystal to protect the surface against aggressive fluids. Silicon crystal, light source and detector are hermetically sealed in a housing. Our tests show that the diamond coating enhanced the sensitivity compared to uncoated ATR elements as predicted by theory.
Max Bergau, Thomas Strahl, Benjamin Scherer, and Jürgen Wöllenstein
J. Sens. Sens. Syst., 12, 61–68, https://doi.org/10.5194/jsss-12-61-2023, https://doi.org/10.5194/jsss-12-61-2023, 2023
Short summary
Short summary
Imaging of greenhouse gases is of great interest due to global warming. A spectroscopic method, using an active illumination of the scene, is presented. It allows for imaging and concentration measurements of much smaller gas plumes and leaks than current state-of-the-art gas cameras (optical gas imaging cameras). A real-time camera is realized and validated using known methane concentrations.
Shazzad Rassel, Md Rejvi Kaysir, Abdulrahman Aloraynan, and Dayan Ban
J. Sens. Sens. Syst., 12, 21–36, https://doi.org/10.5194/jsss-12-21-2023, https://doi.org/10.5194/jsss-12-21-2023, 2023
Short summary
Short summary
Diabetes Mellitus (DM) is one of the very common diseases with no viable cure. However, it can be controlled by regulating the daily sugar intake. Diabetic patients need to prick their fingers a few times a day for monitoring sugar levels. To find an alternative, researchers have been working for decades on the development of a true non-invasive technique. In this effort, we developed a cost-effective non-invasive technique for measuring blood sugar levels using capacitance spectroscopy.
Katrin Schmitt, Mara Sendelbach, Christian Weber, Jürgen Wöllenstein, and Thomas Strahl
J. Sens. Sens. Syst., 12, 37–44, https://doi.org/10.5194/jsss-12-37-2023, https://doi.org/10.5194/jsss-12-37-2023, 2023
Short summary
Short summary
We present a photoacoustic sensor enabling fast, inexpensive, and highly sensitive methane detection in environmental monitoring applications. Six different T-cell designs were both theoretically and experimentally investigated. The aim was to understand the photoacoustic signal generation and resonances in relation to the different cell geometries, and determine the long-term stability and the detection limits for methane. These were below the methane background concentration in air of 1.8 ppm.
Gerald Stocker, Cristina Consani, Pooja Thakkar, Clement Fleury, Andreas Tortschanoff, Khaoula-Farah Ourak, Gerald Pühringer, Reyhaneh Jannesari, Parviz Saeidi, Elmar Aschauer, Ulf Bartl, Christoph Kovatsch, Thomas Grille, and Bernhard Jakoby
J. Sens. Sens. Syst., 11, 225–231, https://doi.org/10.5194/jsss-11-225-2022, https://doi.org/10.5194/jsss-11-225-2022, 2022
Short summary
Short summary
We motivate how integrated waveguides (WGs) can be part of an on-chip non-dispersive infrared sensor system for environmental sensing. We report the hurdles in maintaining WG quality when integrating emitter and detector structures on the same chip. Thus, we introduce the concept of how to determine the intrinsic loss and a process scheme to protect WG structures from damage caused during fabrication. This could pave the way to systems for environmental sensing with a minimal footprint.
Hongyi Zhang, Shéhérazade Azouigui, Rabia Sehab, and Moussa Boukhnifer
J. Sens. Sens. Syst., 11, 187–199, https://doi.org/10.5194/jsss-11-187-2022, https://doi.org/10.5194/jsss-11-187-2022, 2022
Short summary
Short summary
In this paper, a near-infrared LED system is proposed for autonomous vehicles to distinguish between weather-induced road surface conditions (dry, wet, snow, ice, water). For the LED spectra, the influence of the LED bandwidth is investigated. To assess the performance of the system for a long detection range, experiments with large incident angles are conducted. The feasibility of this system is proved via a laboratory experiment with three near-infrared LEDs and a camera.
Tobias Binkele, David Hilbig, Mahmoud Essameldin, Thomas Henning, Friedrich Fleischmann, and Walter Lang
J. Sens. Sens. Syst., 10, 261–270, https://doi.org/10.5194/jsss-10-261-2021, https://doi.org/10.5194/jsss-10-261-2021, 2021
Short summary
Short summary
The development of optical design is characterized by the desire for more applications and better performance. The latest result of this development is freeform optics offering almost unlimited possibilities for the designers. However, an optical component has also to be manufactured and tested by metrology. We propose a measurement technique for the surface characterization of freeform optical components and highlight the possible error sources and their influence on the measurement result.
Sebastian Schramm, Jannik Ebert, Johannes Rangel, Robert Schmoll, and Andreas Kroll
J. Sens. Sens. Syst., 10, 207–218, https://doi.org/10.5194/jsss-10-207-2021, https://doi.org/10.5194/jsss-10-207-2021, 2021
Short summary
Short summary
During the geometric calibration of infrared cameras, the parameters that describe where object points are mapped onto thermal images are determined. The required reference data is obtained by capturing so-called calibration targets. In established approaches, it is difficult to estimate the lens distortions precisely. A newly developed target and its evaluation algorithm make it possible to increase the sensitivity of the calibration by finding reference points close to image borders.
Helmut Budzier and Gerald Gerlach
J. Sens. Sens. Syst., 10, 179–184, https://doi.org/10.5194/jsss-10-179-2021, https://doi.org/10.5194/jsss-10-179-2021, 2021
Short summary
Short summary
In thermometry, the displayed temperature value of an object depends on the size of the object. This behaviour, the size-of-source effect, might be a major cause of measurement uncertainty in a thermoscene. The influence of diffraction and digitization can be described advantageously with the modulation transfer function. Especially with very small objects the displayed temperatures are too low. When imaging large objects, not only the edge areas are affected, but also the entire image.
Felix Lehner, Jürgen Roth, Oliver Hupe, Marc Kassubeck, Benedikt Bergmann, Petr Mánek, and Marcus Magnor
J. Sens. Sens. Syst., 10, 63–70, https://doi.org/10.5194/jsss-10-63-2021, https://doi.org/10.5194/jsss-10-63-2021, 2021
Thomas Strahl, Johannes Herbst, Eric Maier, Sven Rademacher, Christian Weber, Hans-Fridtjof Pernau, Armin Lambrecht, and Jürgen Wöllenstein
J. Sens. Sens. Syst., 10, 25–35, https://doi.org/10.5194/jsss-10-25-2021, https://doi.org/10.5194/jsss-10-25-2021, 2021
Short summary
Short summary
For safety, environmental and economic reasons, methane leak detection is one of the most requested tasks for gas measurement devices. This paper compares the performance of a laser-based optical and acoustical detection scheme at different wavelengths and laser types, respectively. This forms a good basis for further developments of methane leak detection devices or can help to choose the right configuration for a certain methane leak detection application.
Sebastian König, Berndt Gutschwager, Richard Dieter Taubert, and Jörg Hollandt
J. Sens. Sens. Syst., 9, 425–442, https://doi.org/10.5194/jsss-9-425-2020, https://doi.org/10.5194/jsss-9-425-2020, 2020
Short summary
Short summary
We present the metrological characterization and calibration of three different types of thermographic cameras for quantitative temperature measurement traceable to the International Temperature Scale (ITS-90). Relevant technical specifications are determined according to the requirements given in the series of Technical Directives VDI/VDE 5585. For the IETD and the NU, we also show how a significant improvement in the parameters can be achieved with the help of the data reference method.
Maximilian Wohlschläger and Martin Versen
J. Sens. Sens. Syst., 9, 337–343, https://doi.org/10.5194/jsss-9-337-2020, https://doi.org/10.5194/jsss-9-337-2020, 2020
Markus Stoehr, Gerald Gerlach, Thomas Härtling, and Stephan Schoenfelder
J. Sens. Sens. Syst., 9, 209–217, https://doi.org/10.5194/jsss-9-209-2020, https://doi.org/10.5194/jsss-9-209-2020, 2020
Short summary
Short summary
Photoelasticity is considered a useful measurement tool for non-destructive and contactless determination of mechanical stresses or strains in the production of silicon wafers. In this work, a detailed derivation for the anisotropic stress-optic law is presented, and the corresponding stress-optical parameters are measured.
Ulrich Nordmeyer, Niels Neumann, Xiaozhou Wang, Dirk Plettemeier, Torsten Thiel, and Konstantin Kojucharow
J. Sens. Sens. Syst., 9, 199–208, https://doi.org/10.5194/jsss-9-199-2020, https://doi.org/10.5194/jsss-9-199-2020, 2020
Short summary
Short summary
A completely new evaluation method for optical sensors is investigated in this paper. It originates from research that integrates optical sensors into radio-over-fibre networks. The laboratory-based experimental set-up is explained, and the findings are validated by a comparison to the conventional evaluation scheme. Finally, the work provides a detailed mathematical model to understand the implications of this new read-out method for practical applications.
Lakshan Tharmakularajah, Jakob Döring, and Karl-Ludwig Krieger
J. Sens. Sens. Syst., 9, 133–141, https://doi.org/10.5194/jsss-9-133-2020, https://doi.org/10.5194/jsss-9-133-2020, 2020
Short summary
Short summary
In order to differentiate between a wet and a dry road surface, the water film height should be measured by using an infrared-based sensor system. By means of different wavelengths, it is also possible to distinguish between ice and water. In this article, a sensor system for the determination of the physical state of water on different surfaces using infrared LEDs and one photodiode is presented. This shall serve as a basis for the calculation of the road condition.
Mahmoud El-Safoury, Christian Weber, Olaf Kiesewetter, Yvonne Hespos, André Eberhardt, Katrin Schmitt, and Jürgen Wöllenstein
J. Sens. Sens. Syst., 9, 89–97, https://doi.org/10.5194/jsss-9-89-2020, https://doi.org/10.5194/jsss-9-89-2020, 2020
Short summary
Short summary
The refrigerant R134a is classified as a greenhouse gas and was banned from use (in vehicles) by the European Union in 2017 due to its contribution to global warming. The more expensive alternative refrigerant R1234yf is considered an environmentally less harmful alternative owing to its significantly lower global warming potential. Our newly developed gas detector can detect both refrigerants separately and, thus, help prevent the use of illegal gas mixtures that contain both refrigerants.
Elena Kononogova, Albert Adibekyan, Christian Monte, and Jörg Hollandt
J. Sens. Sens. Syst., 8, 233–242, https://doi.org/10.5194/jsss-8-233-2019, https://doi.org/10.5194/jsss-8-233-2019, 2019
Tobias Pohl, Peter Meindl, Uwe Johannsen, Dieter Taubert, and Lutz Werner
J. Sens. Sens. Syst., 8, 195–205, https://doi.org/10.5194/jsss-8-195-2019, https://doi.org/10.5194/jsss-8-195-2019, 2019
Short summary
Short summary
The Physikalisch-Technische Bundesanstalt (PTB) expanded its capabilities in the International System of Units (SI)-traceable absolute measurement of radiant power into the spectral range of the mid-infrared (MIR) by implementing additional MIR laser radiation sources at one of the PTB's cryogenic electrical substitution radiometer facilities. This extension enables absolute calibrations of the spectral responsivity of detectors in the MIR with low uncertainty.
Christian Niklas, Stephan Bauke, Fabian Müller, Kai Golibrzuch, Hainer Wackerbarth, and Georgios Ctistis
J. Sens. Sens. Syst., 8, 123–132, https://doi.org/10.5194/jsss-8-123-2019, https://doi.org/10.5194/jsss-8-123-2019, 2019
Short summary
Short summary
We present in our paper two types of optical sensors that are capable of measuring the environmentally significant gases such as carbon oxide and dioxide as well as methane and water through absorption of light even in harsh environments of high temperature and pressure. Thus the sensors render it possible to measure inside combustion engines or in civilian fireplaces, which is necessary to meet the increasing demands of environmental protection regulations.
Stefan Oertel, Michael Eggert, Christian Gutsmuths, Paul Wilhelm, Harald Müller, and Helmut Többen
J. Sens. Sens. Syst., 8, 9–17, https://doi.org/10.5194/jsss-8-9-2019, https://doi.org/10.5194/jsss-8-9-2019, 2019
Short summary
Short summary
Traceable wind velocity measurements with high resolution play a critical role in the field of wind energy. In this article we present a novel bistatic wind lidar system that has a high spatial and temporal resolution and a reduced measurement uncertainty compared to conventional systems as evidenced by comparison measurements. A first validation measurement in a wind tunnel with a laser Doppler anemometer as a flow velocity reference confirms the high accuracy of the bistatic lidar system.
Martin Weisbrich and Klaus Holschemacher
J. Sens. Sens. Syst., 7, 601–608, https://doi.org/10.5194/jsss-7-601-2018, https://doi.org/10.5194/jsss-7-601-2018, 2018
Short summary
Short summary
The study describes how distributed optical strain measurement can be applied to steel surfaces. With the method presented, strain transfers from the substrate to the fiber core can be achieved that are almost identical to those of the reference measurement, especially with Ormocer® and polyimide coating.
The research results are to be used in the future for strain measurement in concrete construction on reinforcing steel.
Ruben Makris, Falk Hille, Marc Thiele, Dirk Kirschberger, and Damian Sowietzki
J. Sens. Sens. Syst., 7, 259–266, https://doi.org/10.5194/jsss-7-259-2018, https://doi.org/10.5194/jsss-7-259-2018, 2018
Short summary
Short summary
In structural parts under vibrational loading fatigue cracks can initiate and grow, which can lead to structural failure. Conventional non-destructive testing methods for crack detection provide just a snapshot of fatigue crack evolution, whereas crack luminescence coating realizes clear visibility of the entire crack formation. Fatigue causing cyclic tensile tests and examinations on special test bodies allowing control of the crack opening width demonstrate a high sensitivity of the coating.
Markus Brüne, Wilhelm Furian, Wieland Hill, and Andreas Pflitsch
J. Sens. Sens. Syst., 7, 85–90, https://doi.org/10.5194/jsss-7-85-2018, https://doi.org/10.5194/jsss-7-85-2018, 2018
Short summary
Short summary
The climate conditions in underground transportation facilities, especially the current airflow in terms of direction and speed, are the key factor driving smoke propagation in the case of a tunnel fire. Sensing this airflow is cost-intensive. Therefore, this paper focuses on gaining the information from temperature sensing along the tunnels using already installed optical fibers normally used for communications. This technique can replace thousands of temperature sensors.
Christoph Kroh, Roland Wuchrer, Margarita Günther, Thomas Härtling, and Gerald Gerlach
J. Sens. Sens. Syst., 7, 51–55, https://doi.org/10.5194/jsss-7-51-2018, https://doi.org/10.5194/jsss-7-51-2018, 2018
Short summary
Short summary
The inline monitoring of parameters in aqueous liquids is facing an increasing demand in many application areas. In this paper we report on an optical monitoring of the pH value in liquids by means of a sensitive hydrogel, which can be applied in the physiological range. Our results indicate a nearly linear dependency between pH value and hydrogel swelling. Furthermore, we show an improvement of the response time by a factor of 2 in comparison to other systems exploiting this kind of hydrogel.
Beate Oswald-Tranta
J. Sens. Sens. Syst., 7, 13–20, https://doi.org/10.5194/jsss-7-13-2018, https://doi.org/10.5194/jsss-7-13-2018, 2018
Short summary
Short summary
Images of an infrared camera show blurring effects while recording a moving object. Not only the contrast is corrupted by the motion but also the object temperature seems to be lower. It is shown how such images and the true temperature with a good approximation can be restored. Since the detection mechanism of an infrared camera is different from usual digital cameras, also the restoration is different. Examples are presented for motion deblurring used to restore images with different motions.
Roberto Marsili and Gianluca Rossi
J. Sens. Sens. Syst., 6, 361–365, https://doi.org/10.5194/jsss-6-361-2017, https://doi.org/10.5194/jsss-6-361-2017, 2017
Short summary
Short summary
The car production industry is being subjected to more and more pressing technological challenges. In this framework the use of an advanced measurement technique such as thermoelasticity allows the engineers to have a fast and reliable tool for experimental investigation, optimization and validation of the FEM models. In this work it is shown how the thermoelastic measurement technique can be used to optimize a Ferrari car frame.
Christian Rogge, Steffen Zinn, Paolo Prosposito, Roberto Francini, and Andreas H. Foitzik
J. Sens. Sens. Syst., 6, 351–359, https://doi.org/10.5194/jsss-6-351-2017, https://doi.org/10.5194/jsss-6-351-2017, 2017
Short summary
Short summary
This work presents a cost-effective optical-based sensor for pH monitoring of sample volumes less than 150 µL. As part of a bigger project to develop a stand-alone micro bioreactor system, measurements carried out with phenol red and DMEM reported a standard error of calibration in the physiologic pH range (6.5–7.5) of pH ±0.04. Compared to other accessible optical-based sensors this reported system is a good alternative regarding the overall costs of less than EUR 50.
Henrik Zimmermann, Mathias Wiese, Luigi Fiorani, and Alessandro Ragnoni
J. Sens. Sens. Syst., 6, 155–161, https://doi.org/10.5194/jsss-6-155-2017, https://doi.org/10.5194/jsss-6-155-2017, 2017
Short summary
Short summary
Because of their direct impact on patients, medical supply lines are under strict regulations and have to be monitored in terms of purity on a regular basis. State-of-the-art measurement solutions do not allow for continuous bedside monitoring. The aim of the presented work is to provide a compact multispecies monitoring system based on the latest quantum cascade laser technologies allowing for the continuous bedside monitoring of medical gases.
T. Ott, M. Schossig, V. Norkus, and G. Gerlach
J. Sens. Sens. Syst., 4, 313–319, https://doi.org/10.5194/jsss-4-313-2015, https://doi.org/10.5194/jsss-4-313-2015, 2015
M. Mohebbi
J. Sens. Sens. Syst., 4, 209–215, https://doi.org/10.5194/jsss-4-209-2015, https://doi.org/10.5194/jsss-4-209-2015, 2015
U. Kienitz
J. Sens. Sens. Syst., 3, 265–271, https://doi.org/10.5194/jsss-3-265-2014, https://doi.org/10.5194/jsss-3-265-2014, 2014
T. Bley, E. Pignanelli, and A. Schütze
J. Sens. Sens. Syst., 3, 121–132, https://doi.org/10.5194/jsss-3-121-2014, https://doi.org/10.5194/jsss-3-121-2014, 2014
Cited articles
Aiuppa, A., Federicao, C., Giudice, G., and Gurrieri, S.: Chemical mapping of a fumarolic field: La Fossa Crater, Vulcano Island (Aeolian Islands, Italy), Geophys. Res. Lett., 32, L13309, https://doi.org/10.1029/2005GL023207, 2005.
Aiuppa, A., Federico, C., Giudice, G., Gurrieri, S., and Valenza, M.: Hydrothermal buffering of the SO2/H2S ratio in volcanic gases: Evidence from La Fossa Crater fumarolic field, Vulcano Island, Geophys. Res. Lett., 33, L21315, https://doi.org/10.1029/2006GL027730, 2006.
Aiuppa, A., Moretti, R., Federico, C., Giudice, G., Gurrieri, S., Liuzzo, M., Papale, P., Shinohara, H., and Valenza, M.: Forecasting Etna eruptions by real-time observation of volcanic gas composition, Geology, 35, 1115, https://doi.org/10.1130/G24149A.1, 2007.
Allard, P., Burton, M., and Muré, F.: Spectroscopic evidence for a lava fountain driven by previously accumulated magmatic gas, Nature, 433, 407–410, https://doi.org/10.1038/nature03246, 2005.
Bogumil, K., Orphal, J., Homann, T., Voigt, S., Spietz, P., Fleischmann, O. C., Vogel, A., Hartmann, M., Bovensmann, H., Frerick, J., and Burrows, J. P.: Measurementsof molecular absorption spectra with the SCIAMACHY pre-flight model: Instrument characterization and reference data for atmospheric remote sensing in the 230–-2380 nm region, J. Photoch. Photobio. A, 157, 167–184, 2003.
Burton, M. R., Oppenheimer, C. M., Horrocks, L. A., and Francis, P. W.: Remote sensing of CO2 and H2O emission rates from Masaya volcano, Nicaragua, Geology, 28, 915–918, 2000.
Burton, M. R., Sawyer, G. M., and Granieri, D.: Deep Carbon Emissions from Volcanoes, Rev. Mineral. Geochem., 75, 323–354, https://doi.org/10.2138/rmg.2013.75.11, 2013.
Burton, M., Allard, P., Muré, F., and La Spina, A.: Magmatic gas composition reveals the source depth of slug-driven strombolian explosive activity., Science, 80, 227–230, https://doi.org/10.1126/science.1141900, 2007.
Carapezza, M. L., Barberi, F., Ranaldi, M., Ricci, T., Tarchini, L., Barrancos, J., Fischer, C., Perez, N., Weber, K., Di Piazza, A., and Gattuso, A.: Diffuse CO2 soil degassing and CO2 and H2S concentrations in air and related hazards at Vulcano Island (Aeolian arc, Italy), J. Volcanol. Geoth. Res., 207, 130–144, https://doi.org/10.1016/j.jvolgeores.2011.06.010, 2011.
Carn, S. A., Krotkov, N. A., Yang, K., and Krueger, A. J.: Measuring global volcanic degassing with the Ozone Monitoring Instrument (OMI), in: Remote Sensing of Volcanoes and Volcanic Processes: Integrating Observations and Modelling, edited by: Pyle, D. M., Mather, T. A., and Biggs, J., Geological Society, London, 2013.
Chan, K. L., Pöhler, D., Kuhlmann, G., Hartl, A., Platt, U., and Wenig, M. O.: NO2 measurements in Hong Kong using LED based long path differential optical absorption spectroscopy, Atmos. Meas. Tech., 5, 901–912, https://doi.org/10.5194/amt-5-901-2012, 2012.
Duffell, H. J., Oppenheimer, C., Pyle, D. M., Galle, B., McGonigle, A. J., and Burton, M. R.: Changes in gas composition prior to a minor explosive eruption at Masaya volcano, Nicaragua, J. Volcanol. Geoth. Res., 126, 327–339, https://doi.org/10.1016/S0377-0273(03)00156-2, 2003.
Galle, B., Johansson, M., Rivera, C., Zhang, Y., Kihlman, M., Kern, C., Lehmann, T., Platt, U., Arellano, S., and Hidalgo, S.: Network for Observation of Volcanic and Atmospheric Change (NOVAC) – A global network for volcanic gas monitoring: Network layout and instrument description, J. Geophys. Res., 115, D05304, https://doi.org/10.1029/2009JD011823, 2010.
Gerlach, T. M., Delgado, H., Mcgee, K. A., Doukas, M. P., Venegas, J. J., and Cardenas, L.: Application of the LI-COR CO2 analyzer to volcanic plumes: A case study, volcan Popocatepetl, Mexico, 7 and 10 June, 1995, J. Geophys. Res., 102, 8005–8019, 1997.
Gerlach, T. M., Mcgee, K. A., Sutton, A. J., and Elias, T.: Rates of volcanic CO2 degassing from airborne determinations of SO2 emission rates and plume CO2/SO2: Test study at Pu`u `O`o Cone, Kilauea volcano, Hawaii, Geophys. Res. Lett., 25, 2675–2678, 1998.
Giggenbach, W. F. and Goguel, R. L.: Methods for collection and analysis of geothermal and volcanic water and gas samples, Dep. Sci. Ind. Res. Chem. Div., Report 240, 1989.
Grainger, J. F. and Ring, J.: Anomalous Fraunhofer Line Profiles, Nature, 193, 762 pp., 1962.
Halmer, M. M., Schmincke, H.-U., and Graf, H.-F., The annual volcanic gas input into the atmosphere, in particular into the stratosphere: a global data set for the past 100 years, J. Volcanol. Geoth. Res., 115, 511–528, https://doi.org/10.1016/S0377-0273(01)00318-3, 2002.
Kern, C., Trick, S., Rippel, B., and Platt, U.: Applicability of light-emitting diodes as light sources for active differential optical absorption spectroscopy measurements, Appl. Optics, 45, 2077–2088, 2006.
Kern, C., Sihler, H., Vogel, L., Rivera, C., Herrera, M., and Platt, U.: Halogen oxide measurements at Masaya Volcano, Nicaragua using active long path differential optical absorption spectroscopy, B. Volcanol., 71, 659–670, https://doi.org/10.1007/s00445-008-0252-8, 2008.
Kern, C., Deutschmann, T., Vogel, L., Wöhrbach, M., Wagner, T., and Platt, U.: Radiative transfer corrections for accurate spectroscopic measurements of volcanic gas emissions, B. Volcanol., 72, 233–247, https://doi.org/10.1007/s00445-009-0313-7, 2009.
Lee, C., Kim, Y. J., Tanimoto, H., Bobrowski, N., Platt, U., Mori, T., Yamamoto, K., and Hong, C. S.: High ClO and ozone depletion observed in the plume of Sakurajima volcano, Japan, Geophys. Res. Lett., 32, 10–13, https://doi.org/10.1029/2005GL023785, 2005.
Merten, A., Tschritter, J., and Platt, U.: Design of differential optical absorption spectroscopy long-path telescopes based on fiber optics, Appl. Optics, 50, 738–54, 2011.
O'Dwyer, M.: Real-time measurement of volcanic H2S and SO2 concentrations by UV spectroscopy, Geophys. Res. Lett., 30, 12–15, https://doi.org/10.1029/2003GL017246, 2003.
Ohba, T., Daita, Y., Sawa, T., Taira, N., and Kakuage, Y.: Coseismic changes in the chemical composition of volcanic gases from the Owakudani geothermal area on Hakone volcano, Japan, B. Volcanol., 73, 457–469, https://doi.org/10.1007/s00445-010-0445-9, 2011.
Oppenheimer, C., Francis, P., Burton, M., Maciejewski, A. J. H., and Boardman, L.: Remote measurement of volcanic gases by Fourier transform infrared spectroscopy, Appl. Phys. B, 67, 505–515, 1998.
Oppenheimer, C., Scaillet, B., and Martin, R. S.: Sulfur Degassing From Volcanoes: Source Conditions, Surveillance, Plume Chemistry and Earth System Impacts, Rev. Mineral. Geochem., 73, 363–421, https://doi.org/10.2138/rmg.2011.73.13, 2011.
Pedone, M., Aiuppa, A., Giudice, G., Grassa, F., Cardellini, C., Chiodini, G., and Valenza, M.: Volcanic CO2 flux measurement at Campi Flegrei by tunable diode laser absorption spectroscopy, B. Volcanol., 76, 812, https://doi.org/10.1007/s00445-014-0812-z, 2014.
Pering, T. D., Tamburello, G., McGonigle, A. J. S., Aiuppa, A., Cannata, A., Giudice, G., and Patanè, D.: High time resolution fluctuations in volcanic carbon dioxide degassing from Mount Etna, J. Volcanol. Geoth. Res., 270, 115–121, https://doi.org/10.1016/j.jvolgeores.2013.11.014, 2014.
Platt, U. and Stutz, J.: Differential Optical Absorption Spectroscopy, Springer, Berlin, Heidelberg, 2008.
Platt, U., Perner, D., and Patz, H. W.: Simultaneous Measurement of Atmospheric CH2O, 03, and NO2 by Differential Optical Absorption, J. Geophys. Res., 84, 6329–6335, 1979.
Rasmussen, R. A., Khalil, M. A., Dalluge, R. W., Penkett, S. A., and Jones, B.: Carbonyl sulfide and carbon disulfide from the eruptions of mount st. Helens., Science, 215, 665–667, https://doi.org/10.1126/science.215.4533.665, 1982.
Rawlins, W. T., Hensley, J. M., Sonnenfroh, D. M., Oakes, D. B., and Allen, M. G.: Quantum cascade laser sensor for SO2 and SO3 for application to combustor exhaust streams, Appl. Optics, 44, 6635–6643, 2005.
Richter, D., Erdelyi, M., Curl, R. F., Tittel, F. K., Oppenheimer, C., Duffell, H. J., and Burton, M.: Field measurements of volcanic gases using tunable diode laser based mid-infrared and Fourier transform infrared spectrometers, Opt. Laser Eng., 37, 171–186, https://doi.org/10.1016/S0143-8166(01)00094-X, 2002.
Roberts, T. J., Braban, C. F., Oppenheimer, C., Martin, R. S., Freshwater, R. A., Dawson, D. H., Griffiths, P. T., Cox, R. A., Saffell, J. R., and Jones, R. L.: Electrochemical sensing of volcanic gases, Chem. Geol., 332–333, 74–91, https://doi.org/10.1016/j.chemgeo.2012.08.027, 2012.
Roberts, T. J., Saffell, J. R., Oppenheimer, C., and Lurton, T.: Electrochemical sensors applied to pollution monitoring: Measurement error and gas ratio bias –- A volcano plume case study, J. Volcanol. Geoth. Res., 281, 85–96, https://doi.org/10.1016/j.jvolgeores.2014.02.023, 2014.
Schiff, H. I., Mackay, G. I., and Bechara, J.: The use of tunable diode laser absorption spectroscopy for atmospheric measurements, in: Air Monitoring by Spectroscopic Techniques, edited: by M. W. Sigrist, 239–333, John Wiley and Sons, Inc., New York, Chister, Brisbane, Toronto, Singapore, 1994.
Shinohara, H.: A new technique to estimate volcanic gas composition: plume measurements with a portable multi-sensor system, J. Volcanol. Geoth. Res., 143, 319–333, https://doi.org/10.1016/j.jvolgeores.2004.12.004, 2005.
Shinohara, H., Aiuppa, A., Giudice, G., Gurrieri, S., and Liuzzo, M.: Variation of H2O/CO2 and CO2/SO2 ratios of volcanic gases discharged by continuous degassing of Mount Etna volcano, Italy, J. Geophys. Res., 113, B09203, https://doi.org/10.1029/2007JB005185, 2008.
Shinohara, H., Matsushima, N., Kazahaya, K., and Ohwada, M.: Magma-hydrothermal system interaction inferred from volcanic gas measurements obtained during 2003–2008 at Meakandake volcano, Hokkaido, Japan, B. Volcanol., 73, 409–421, https://doi.org/10.1007/s00445-011-0463-2, 2011.
Sihler, H., Kern, C., Pöhler, D., and Platt, U.: Applying light-emitting diodes with narrowband emission features in differential spectroscopy., Opt. Lett., 34, 3716–3718, 2009.
Stoiber, R. E., Leggett, D. C., Jenkins, T. F., Murrmann, R. P., and Rose, W. I.: Organic Compounds in Volcanic Gas from Santiaguito Volcano, Guatemala, Geol. Soc. Am. Bull., 82, 2299–2302, 1971.
Stremme, W., Krueger, A., Harig, R., and Grutter, M.: Volcanic SO2 and SiF4 visualization using 2-D thermal emission spectroscopy – Part 1: Slant-columns and their ratios, Atmos. Meas. Tech., 5, 275–288, https://doi.org/10.5194/amt-5-275-2012, 2012.
Symonds, R. B., Gerlach, T. M., and Reed, M. H.: Magmatic gas scrubbing: implications for volcano monitoring, J. Volcanol. Geoth. Res., 108, 303–341, https://doi.org/10.1016/S0377-0273(00)00292-4, 2001.
Tittel, F. K., Lewicki, R., Lascola, R., and McWhorter, S.: Emerging Infrared Laser Absorption Spectroscopic Techniques for Gas Analysis, in: Trace Analysis of Specialty and Electronic Gases, edited by: Geiger, W. M. and Raynor, M. W., 71–110, John Wiley and Sons, Inc., New York, Chister, Brisbane, Toronto, Singapore, 2012.
Vandaele, A. C., Hermans, C., and Fally, S.: Fourier transform measurements of SO2 absorption cross sections: II. Temperature dependence in the 29000-44000 cm−1 (345–420 nm) region, J. Quant. Spectrosc. Ra., 110, 2115–2126, 2009.
Vita, F., Inguaggiato, S., Bobrowski, N., Calderone, L., Galle, B., and Parello, F.: Continuous SO2 flux measurements for Vulcano Island, Italy, Ann. Geophys., 55, 301–308, https://doi.org/10.4401/ag-5759, 2012.
Wahner, A., Ravishankara, A. R., Sander, S. P., and Friedl, R. R.: Absorption cross section of BrO between 312 and 385 nm at 298 and 223 K, Chem. Phys. Lett., 152, 507–512, 1988.
Werner, C., Evans, W. C., Kelly, P. J., McGimsey, R., Pfeffer, M., Doukas, M., and Neal, C.: Deep magmatic degassing versus scrubbing: Elevated CO2 emissions and C/S in the lead-up to the 2009 eruption of Redoubt Volcano, Alaska, Geochem. Geophy. Geosyst., 13, Q03015, https://doi.org/10.1029/2011GC003794, 2012.
Werner, C., Kelly, P. J., Doukas, M., Lopez, T., Pfeffer, M., McGimsey, R., and Neal, C.: Degassing of CO2, SO2, and H2S associated with the 2009 eruption of Redoubt Volcano, Alaska, J. Volcanol. Geotherm. Res., 259, 270–284, https://doi.org/10.1016/j.jvolgeores.2012.04.012, 2013.
Yu, Y., Geyer, A., Xie, P., Galle, B., Chen, L., and Platt, U.: Observations of carbon disulfide by differential optical absorption spectroscopy in Shanghai, Geophys. Res. Lett., 31, L11107, https://doi.org/10.1029/2004GL019543, 2004.