Articles | Volume 9, issue 2
https://doi.org/10.5194/jsss-9-425-2020
https://doi.org/10.5194/jsss-9-425-2020
Regular research article
 | 
18 Dec 2020
Regular research article |  | 18 Dec 2020

Metrological characterization and calibration of thermographic cameras for quantitative temperature measurement

Sebastian König, Berndt Gutschwager, Richard Dieter Taubert, and Jörg Hollandt

Related authors

Particularities of pyroelectric detectors in absolute measurements of chopped radiation shown for the example of a spectral responsivity calibration in the near- and mid-infrared spectral range at two primary radiometric standards
Tobias Pohl, Peter Meindl, Jörg Hollandt, Uwe Johannsen, and Lutz Werner
J. Sens. Sens. Syst., 11, 61–73, https://doi.org/10.5194/jsss-11-61-2022,https://doi.org/10.5194/jsss-11-61-2022, 2022
Short summary
Absolute calibration of the spectral responsivity of thermal detectors in the near-infrared (NIR) and mid-infrared (MIR) regions by using blackbody radiation
Tobias Pohl, Peter Meindl, Lutz Werner, Uwe Johannsen, Dieter Taubert, Christian Monte, and Jörg Hollandt
J. Sens. Sens. Syst., 10, 109–119, https://doi.org/10.5194/jsss-10-109-2021,https://doi.org/10.5194/jsss-10-109-2021, 2021
Short summary
Characterization, calibration and validation of an industrial emissometer
Elena Kononogova, Albert Adibekyan, Christian Monte, and Jörg Hollandt
J. Sens. Sens. Syst., 8, 233–242, https://doi.org/10.5194/jsss-8-233-2019,https://doi.org/10.5194/jsss-8-233-2019, 2019
Measurement of the absolute spectral responsivity in the mid-infrared based on the cryogenic electrical substitution radiometer and an optimized thermopile detector
Tobias Pohl, Peter Meindl, Uwe Johannsen, Dieter Taubert, and Lutz Werner
J. Sens. Sens. Syst., 8, 195–205, https://doi.org/10.5194/jsss-8-195-2019,https://doi.org/10.5194/jsss-8-195-2019, 2019
Short summary
A large-area blackbody for in-flight calibration of an infrared interferometer deployed on board a long-duration balloon for stratospheric research
Friedhelm Olschewski, Christian Monte, Albert Adibekyan, Max Reiniger, Berndt Gutschwager, Joerg Hollandt, and Ralf Koppmann
Atmos. Meas. Tech., 11, 4757–4762, https://doi.org/10.5194/amt-11-4757-2018,https://doi.org/10.5194/amt-11-4757-2018, 2018
Short summary

Related subject area

Sensor principles and phenomena: Optical and infrared sensors
Real-time active-gas imaging of small gas leaks
Max Bergau, Thomas Strahl, Benjamin Scherer, and Jürgen Wöllenstein
J. Sens. Sens. Syst., 12, 61–68, https://doi.org/10.5194/jsss-12-61-2023,https://doi.org/10.5194/jsss-12-61-2023, 2023
Short summary
Non-invasive blood sugar detection by cost-effective capacitance spectroscopy
Shazzad Rassel, Md Rejvi Kaysir, Abdulrahman Aloraynan, and Dayan Ban
J. Sens. Sens. Syst., 12, 21–36, https://doi.org/10.5194/jsss-12-21-2023,https://doi.org/10.5194/jsss-12-21-2023, 2023
Short summary
Resonant photoacoustic cells for laser-based methane detection
Katrin Schmitt, Mara Sendelbach, Christian Weber, Jürgen Wöllenstein, and Thomas Strahl
J. Sens. Sens. Syst., 12, 37–44, https://doi.org/10.5194/jsss-12-37-2023,https://doi.org/10.5194/jsss-12-37-2023, 2023
Short summary
Fabrication of integrated polysilicon waveguides for mid-infrared absorption sensing
Gerald Stocker, Cristina Consani, Pooja Thakkar, Clement Fleury, Andreas Tortschanoff, Khaoula-Farah Ourak, Gerald Pühringer, Reyhaneh Jannesari, Parviz Saeidi, Elmar Aschauer, Ulf Bartl, Christoph Kovatsch, Thomas Grille, and Bernhard Jakoby
J. Sens. Sens. Syst., 11, 225–231, https://doi.org/10.5194/jsss-11-225-2022,https://doi.org/10.5194/jsss-11-225-2022, 2022
Short summary
Near-infrared LED system to recognize road surface conditions for autonomous vehicles
Hongyi Zhang, Shéhérazade Azouigui, Rabia Sehab, and Moussa Boukhnifer
J. Sens. Sens. Syst., 11, 187–199, https://doi.org/10.5194/jsss-11-187-2022,https://doi.org/10.5194/jsss-11-187-2022, 2022
Short summary

Cited articles

Budzier, H. and Gerlach, G.: Thermal infrared sensors: theory, optimisation and practice, John Wiley & Sons, USA, 2011. 
Deutsches Patent- und Markenamt: Verfahren zum Ermitteln von Korrekturparametern zum Korrigieren von Messwerten von Bildpunkten, um die Ungleichheit des Übertragungsverhaltens einzelner oder aller Bildpunkte eines Bildaufnahmesystems zu korrigieren, Deutsches Patent- und Markenamt, Germany, 10 2014 018 340.8, 2014. 
German standard DIN IEC/TS 62492-2: Industrial process control devices – Radiation thermometers – Determination of the technical data for radiation thermometers (IEC/TS 62492-2:2013), Berlin, 2014. 
Gutschwager, B. and Hollandt, J.: Nonuniformity correction of imaging systems with a spatially nonhomogeneous radiation source, Appl. Optics, 54, 10599–10605, 2015. 
Gutschwager, B. and Hollandt, J.: Nonuniformity correction of infrared cameras by reading radiance temperatures with a spatially nonhomogeneous radiation source, Meas. Sci. Technol., 28, 015401, https://doi.org/10.1088/1361-6501/28/1/015401, 2017. 
Download
Short summary
We present the metrological characterization and calibration of three different types of thermographic cameras for quantitative temperature measurement traceable to the International Temperature Scale (ITS-90). Relevant technical specifications are determined according to the requirements given in the series of Technical Directives VDI/VDE 5585. For the IETD and the NU, we also show how a significant improvement in the parameters can be achieved with the help of the data reference method.