Articles | Volume 7, issue 1
https://doi.org/10.5194/jsss-7-331-2018
https://doi.org/10.5194/jsss-7-331-2018
Regular research article
 | 
03 May 2018
Regular research article |  | 03 May 2018

Bilateral comparison for determining the dynamic characteristic values of contact thermometers in fluids

Silke Augustin, Thomas Fröhlich, Marc Schalles, and Stefan Krummeck

Related authors

New publication of the VDI/VDE guideline 3520 “Surface temperature measurement with contact thermometers” – contents and background of the development
Silke Augustin and Marc Schalles
J. Sens. Sens. Syst., 12, 197–204, https://doi.org/10.5194/jsss-12-197-2023,https://doi.org/10.5194/jsss-12-197-2023, 2023
Short summary

Related subject area

Measurement theory, uncertainty and modeling of measurements: Measurement uncertainty
Metrological assessment of a robotic total station for use in post-earthquake emergency conditions
Giulio D'Emilia and Emanuela Natale
J. Sens. Sens. Syst., 12, 187–195, https://doi.org/10.5194/jsss-12-187-2023,https://doi.org/10.5194/jsss-12-187-2023, 2023
Short summary
Approximate sequential Bayesian filtering to estimate 222Rn emanation from 226Ra sources using spectral time series
Florian Mertes, Stefan Röttger, and Annette Röttger
J. Sens. Sens. Syst., 12, 147–161, https://doi.org/10.5194/jsss-12-147-2023,https://doi.org/10.5194/jsss-12-147-2023, 2023
Short summary
Evaluation of precision, accuracy and threshold for the design of vibrotactile feedback in eye tracking applications
Anke Fischer, Thomas M. Wendt, Lukas Stiglmeier, Philipp Gawron, and Kristof Van Laerhoven
J. Sens. Sens. Syst., 12, 103–109, https://doi.org/10.5194/jsss-12-103-2023,https://doi.org/10.5194/jsss-12-103-2023, 2023
Short summary
Influence of measurement uncertainty on machine learning results demonstrated for a smart gas sensor
Tanja Dorst, Tizian Schneider, Sascha Eichstädt, and Andreas Schütze
J. Sens. Sens. Syst., 12, 45–60, https://doi.org/10.5194/jsss-12-45-2023,https://doi.org/10.5194/jsss-12-45-2023, 2023
Short summary
Towards efficient application-dependent dimensional measurements with computed tomography: optimized reduction of measurement duration using continuous scan mode: experimental investigations
Christian Orgeldinger, Florian Wohlgemuth, Andreas Michael Müller, and Tino Hausotte
J. Sens. Sens. Syst., 11, 219–223, https://doi.org/10.5194/jsss-11-219-2022,https://doi.org/10.5194/jsss-11-219-2022, 2022
Short summary

Cited articles

Augustin, S. and Fröhlich, T.: Dynamisches Verhalten von Berührungsthermometern, tm-Tech. Mess. 83, 402–409, https://doi.org/10.1515/teme-2015-0068, 2017. 
Augustin, S., Fröhlich, T., and Ament, C.: Temperature-Dependent Dynamic Behaviour of Process Temperature Sensors, International Journal of Thermophysics, Springer Verlag, https://doi.org/10.1007/s10765-015-1869-4, 2015. 
Augustin, S., Fröhlich, T., and Heydrich, M.: Bestimmung der Messunsicherheit dynamischer Kennwerte von Berührungsthermometern in strömender Luft, tm-Tech. Mess., 84, 73–82, https://doi.org/10.1515/teme-2016-0055, 2017. 
Bernhard, F.: Handbuch der Technischen Temperaturmessung, 2. Auflage, Springer-Verlag, 2014. 
DAkkS: DAkkS-DKD-R 5-3: Kalibrierung von Thermoelementen, Beuth-Verlag, 1. Neuauflage, 2010a. 
Download
Short summary
In the data sheets of the thermometer manufacturers, different specifications can be found to describe the dynamic properties of contact thermometers. The present paper describes the results of a bilateral comparison made for the first time for determining dynamic parameters for two thermocouples in the laboratories of the JUMO GmbH & Co. KG Fulda company and at the Institute of Process Measurement and Sensor Technology of the TU Ilmenau with similar facilities, but different results.